User manual
18
III.b.17) About the program
When this option is selected the display will show the software version of the active valve
module.
III.c)Valve 2
All settings for valve 2 are made in the same way as in the case of valve 1.
III.d) GSM module
NOTE: Controlling of this type is possible after purchasing and connecting, to the controller,
the additional control module ST-65 which is not attached to the regulator as a standard
feature.
The GSM module is an optional device cooperating with the boiler controller, enabling remote
control of the boiler operation with the use of a mobile phone. The User is notified with a text
message on each alert of the boiler controller, and by sending an appropriate text message at
any time, he or she receives a return message with the information on the current temperature
of all sensors. After entering an authentication code it is also possible to remotely change the
set temperatures.
The GSM module can also operate independently from the boiler controller. It has two
inputs with temperature sensors, single contact input for use in any configuration (detecting
short circuit/opening of contacts) and one controlled output (e.g. possibility to connect
additional contactor to control any electrical circuit).
When any temperature sensor reaches the preset deactivation temperature, maximum
or minimum, the module will automatically send a text message with such information. It is
similar in the case of a short-circuit or opening of contact input, which may be used e.g. for
simple protection of property.
III.e) Internet module
NOTE: Controlling of this type is possible after purchasing and connecting, to the controller,
the additional control module ST-500 which is not attached to the regulator as a standard
feature.
The Internet module is a device enabling remote control of the boiler over the Internet or local
network . On the home computer screen the user controls the condition of all boiler system
devices and the operation of each device is presented in the animated form.
Apart from the possibility to view the temperature of every sensor, the user has the possibility
of introducing changes of the set temperatures for both the pumps and the mixing valves.
After activating the Internet module and selecting the DHCP option, the controller will
automatically download such parameters from the local network as: IP address, IP Mask,
Gateway address and DNS Address. In the case of any problems with downloading network
parameters of the existing network, there is a possibility of setting these parameters manually.
The method of obtaining local network parameters has been described in the instructions for
the Internet module.
The function Reset module password may be used when the User, on the login page, has
changed the factory user's password to his or her password. When a new password is lost, it is
possible to return to the factory password after resetting the module password.