. Maintenance
Maintenance
Maintenance
Maintenance and
and
and
and Cleaning
Cleaning
Cleaning
Cleaning
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be
corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling,
suspension, trussing).
3)Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.
4)The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer
and any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the
lights.
1) Clean the inside and outside lens each week to avoid the weakneness of the lights due to accumulation
of dust.
2) Clean the fan each week.
3) A detailed electric check by approved electrical engineer each three month, make sure that the circuit
contacts are in good condition, prevent the poor contact of circuit from overheating.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or
solvents.
There are no serviceable parts inside the device. Please refer to the instructions under “Installation
instructions”.
Should you need any spare parts, please order genuine parts from your local dealer.

1.
1.
1.
1. Un
Un
Un
Unpacking
packing
packing
packing
Thank you for choosing OCTOBEAM For your own safety, please read this manual
before installing the device. This manual covers the important information on installation and
applications. Please install and operate the fixture with following instructions. Meanwhile, please
keep this manual well for future needs.
OCTOBEAM is made of a new type of high temperature strength of engineering plastics
and cast aluminum casing with nice outlook. The fixture is designed and manufactured strictly
following CE standards, complying with international standard DMX512 protocol. It
’
s available
independently controlled and linkable with each other for operation. And it is applicable for small to
medium live performances, theater, studio, nightclubs and discos.
OCTOBEAM adopts 8PCS high power 8W White LEDs which features high brightness
and stability. Please carefully unpack it when you receive the fixture and check whether it is
damaged during the transportation. And please check whether the following items are included
inside the box:
OCTOBEAM ---------One Signal Cable----One
Omega Clamp-------Two Power Cable----One
Safety Chain---------One User Manual----One
9.
9.
9.
9. Key
Key
Key
Key Features
Features
Features
Features
8PCS 8W high power WHITE LEDs
100,000 hours lifespan and low power consumption
8 pixels (each LED is a pixel), controllable individually
Outstanding white BEAM effect
Specific optic system
High light output with 4870LUX@7M for 8 BEAMs, 1770LUX@7M for 1 BEAM
High efficiency LED shutter
Strobe effect with 18 flashes per second and pulse effect
0-100% smooth NEO-HLP-80
Amazing streaming effect
8 built-in default programs for easy performance
12 default pixel macros effect
14/15 DMX channels
DMX512, master-slave and sound activated controllable or auto operation
LED display
Efficient Noise free aluminum cooling system
Powercon IN/OUT as default
3-pin XLR connectors
Two 1/4 turn fastening Omega Clamps
10.
10.
10.
10. Technical
Technical
Technical
Technical Specifications
Specifications
Specifications
Specifications
Input Voltage: AC90-260V 50/60Hz
LED Quantities: 8PCS 8W WHITE LEDs
Control Signal: DMX512, master-slave and sound activated or auto operation
Control Channel: 14/15 DMX Channels switchable
Power Consumption: 120W
Dimensions: 84(D)x1064(W)x180(H)mm
Packing Dimensions: 165(D)x1165(W)x220(H)mm
Net Weight: 7.5kg
Gross Weight: 10kg

14 13 Pixel 8 0-255 Pixel 8 saturaon control (0-100%)
15 14 Pixel Macro
0-015 No funcon
016-035 Macro 1 from slow to fast
036-055 Macro 2 from slow to fast
056-075 Macro 3 from slow to fast
076-095 Macro 4 from slow to fast
096-115 Macro 5 from slow to fast
116-135 Macro 6 from slow to fast
136-155 Macro 7 from slow to fast
156-175 Macro 8 from slow to fast
176-195 Macro 9 from slow to fast
196-215 Macro 10 from slow to fast
216-235 Macro 11 from slow to fast
236-255 Macro 12 from slow to fast
2.
2.
2.
2. S
S
S
Safety
afety
afety
afety I
I
I
Instructions
nstructions
nstructions
nstructions
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a
safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
If the device has been exposed to temperature changes due to environmental changes, do not switch
it on immediately. The arising condensation could damage the device. Leave the device switched off
until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be earthed.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case,
replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the
power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not
necessarily mean that the device is defective, it should decrease gradually.
Please don't project the beam onto combustible substances.
Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for
smooth air flow, so there should be no shelter for fans and ventilation for heat radiation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the
manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

3.
3.
3.
3. Operation
Operation
Operation
Operation Ins truc tions
Ins truc tions
Ins truc tions
Ins truc tions
-T he OCTOBEAM is for beam effect for on-s ite decoration purpos e.
-Don’t turn on the fixture if it
’
s been through severe temperature difference like after
trans porta tion beca use it might damage the light due to the environment changes . S o make s ure
to operate the fixture until it is in normal temperature.
-T his light should be keep away from strong shaking during any trans portation or movement.
-Don’t pull up the light by only the head, or it might cause damages to the mechanical parts.
-Don’t expose the fixture in overheat, moisture or environment with too much dust when ins talling
it. And don’t lay any power ca bles on the floor. O r it might cause electronic s hock to the people.
-Make s ure the installation place is in good safety condition before installing the fixture.
-Make s ure to put the safety chain and check whether the sc rews are sc rewed properly when
installing the fixture.
-Make s ure the lens are in good condition. It
’
s recommended to replace the units if there are any
damages or s evere sc ratch.
-Make s ure the fixture is operated by qualified personnel who knows the fixture before using.
-K e ep the origina l pa ck age s if any s ec ond s hipment is nee ded.
-Don’t try to change the fixtures without any instruction by the manufacturer or the appointed
repa iring a gencies .
-It is not in warra nty range if there are any malfunctions from not following the user manual to
operate or any illegal operation, like shock s hort circuit, electronic s hock, lamp broke, etc.
4.
4.
4.
4. Mounting
Mounting
Mounting
Mounting and
and
and
and Ins tallation
Ins tallation
Ins tallation
Ins tallation
Cau ons:
Cau ons:
Cau ons:
Cau ons: For added protec on mount the fixtures in areas outside walking paths, sea ng areas, or in
areas were the fixture might be reached by
unauthorized personnel.
Before moun ng the fixture to any surface, make sure that the installa on area can hold a minimum
point load of 10 mes the device
’
s weight.
Fixture installa on must always be secured with a secondary safety a achment, such as an appropriate
safety cable.
Never stand directly below the device when moun ng, removing, or servicing the fixture.
8.DMX
8.DMX
8.DMX
8.DMX C hannels
C hannels
C hannels
C hannels
C han nel
C han nel
C han nel
C han nel Fu nction
Fu nction
Fu nction
Fu nction Values
Values
Values
V alu es Des c ripti on
Des c ripti on
Des c ripti on
Des c ripti on
MOD1 MOD 2
1 1 Dimmer 0-255 Dimmer 0%...100%
2 2 Shu er
0-009 No Func on
010-249 Strobe effect slow to fast
250-255 No Func on
3 3 TILT 0-255 T
ILT
movement
4 TILT Fine 0-255 Fine control of Tilt movement
5 4 Speed 0-255 Max to min speed for TILT
6 5 Special
0-019 No Func on
020-029 No Func on
030-039 No Func on
040-079 No Func on
080-099 Motor reset
100-119 Internal program 1
120-139 Internal program 2
140-159 Internal program 3
160-179 Internal program 4
180-199 Internal program 5
200-219 Internal program 6
220-239 Internal program 7
240-255 Internal program 8
7 6 Pixel 1 0-255 Pixel 1 satura on control (0-100%)
8 7 Pixel 2 0-255 Pixel 1 satura on control (0-100%)
9 8 Pixel 3 0-255 Pixel 1 satura on control (0-100%)
10 9 Pixel 4 0-255 Pixel 1 satura on control (0-100%)
11 10 Pixel 5 0-255 Pixel 1 satura on control (0-100%)
12 11 Pixel 6 0-255 Pixel 1 satura on control (0-100%)
13 12 Pixel 7 0-255 Pixel 1 satura on control (0-100%)

7.
7.
7.
7. Photometric
Photometric
Photometric
Photometric Data
Data
Data
Data
from a ceiling, or set on a flat level surface (see illustra on below). Be sure this fixture is kept at least
0.5m (1.5 ) away from any flammable materials (decora on etc.).
Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or
injury in the event the clamp fails.
Moun ng
Moun ng
Moun ng
Moun ng points
points
points
points:
:
:
:Overhead moun ng requires extensive experience, including amongst others
calcula ng working load limits, a fine knowledge of the installa on material being used, and periodic
safety inspec on of all installa on material and the fixture. If you lack these qualifica ons, do not a empt
the installa on yourself. Improper installa on can result in bodily injury.
Be sure to complete all rigging and installa on procedures before connec ng the main power cord to the
appropriate wall outlet.
Clamp
Clamp
Clamp
Clamp Moun ng
Moun ng
Moun ng
Moun ng:
:
:
:The OCTOBEAM provides two unique moun ng bracket assembly that
integrates the bo om of the base, the included “Omega Bracket,” and the safety cable rigging point in one
unit (see the illustra on below). When moun ng this fixture to truss be sure to secure an appropriately
rated clamp to the included omega bracket using a M10 screw fied through the center hole of the
“omega bracket
”
. As an added safety measure be sure to a ached at least one properly rated safety cable
to the fixture using on of the safety cable rigging point integrated in the base assembly

Regardless of the rigging option you choose for your OCTOBEAM , always be sure to secure your
fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the hanging
bracket as illustrated above. Be sure to only use the designated rigging point for the safety cable and never
secure a safety cable to a carrying handle.
5.
5.
5.
5. DMX-512
DMX-512
DMX-512
DMX-512 control
control
control
control connections
connections
connections
connections
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the
male 3-pin XLR input of the moving head. You can chain multiple
Moving head together through serial linking. The cable needed should be two core, screened cable with
XLR input and output connectors. Please refer to the diagram below.
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in
preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an
XLR plug with a 120 Ωresistor connected between pins 2 and 3,which is then plugged into the output
XLR socket of the last fixture in the chain. Please see illustrations below.
1
1
1
1
2
2
2
2
3
3
3
3
PIN 3
PIN 3
PIN 3
PIN 3
PIN 2
PIN 2
PIN 2
PIN 2
120
120
120
120
Ω
6.
6.
6.
6. Menu
Menu
Menu
Menu Operations
Operations
Operations
Operations
MODE
ADDR
VALU A001~AXXX (AXXX) DMX address setting
SLAV ON/OFF (SLAV) Set to slave
AUTO IP1~8
ALON (AU-A) Running built-in program alone
MAST (AU-M) Set to master (Auto running)
SOUN IP1~8
ALON (SO-A) Set to sound control alone
MAST (SO-M) Set to master (Sound control)
SET
MIC M-XX Mic sensitivity
LODA ON/OFF Reload data
VER V-1.0~V-9.9 Software version
DMX
MOD1 15 DMX channel mode
MOD2 14 DMX channel mode
REST ON/OFF All reset
Other manuals for octobeam
1
Table of contents
Other TECshow Light Fixture manuals

TECshow
TECshow ION 740z User manual

TECshow
TECshow BEAMER 7R User manual

TECshow
TECshow ALFIE WASH User manual

TECshow
TECshow HALO 7R User manual

TECshow
TECshow MINI-HIVE 10 User manual

TECshow
TECshow BEAMER User manual

TECshow
TECshow nebula 18 User manual

TECshow
TECshow NEBULA FX 3-in-1 User manual

TECshow
TECshow Alfie User manual

TECshow
TECshow COSMO QUAD 6 User manual