xx
Operating information
The TPP1000 10X Passive Probe is a high impedance probe
with 10X attenuation that is designed for use with Tektronix
5 Series MSO and MDO3000, MDO/MSO/DPO4000B,
MSO/DPO5000 series ground-referenced oscilloscopes.
Connect the probe as shown in the illustrations below.
Compensating the Probe
You should compensate the probe after you attach it to an
oscilloscope for the first time, or after you have changed the
probe tip cartridge.
1. Connect the probe to an oscilloscope channel.
2. Connect the probe tip and ground to the probe
compensation terminals on the oscilloscope.
NOTE. When using the MMCX tip (206-0663-xx), the following
part numbers are required to connect the tip to the Probe
Comp connections: 131-9717-xx (1), 196-3434-xx (1),
and 206-0569-xx (2). See Connecting the MMCX tip to the
oscilloscope Probe Comp.
3. On 5 Series MSO instruments:
a. Double tap the Channel Badge for the connected
probe.
b. Select the Probe Setup.
c. Select Compensate Probe.
d. Select Compensate Probe in the pop up window.
4. On MSO/DPO5000 instruments:
a. Select Vertical > Probe Cal....
b. Select the tab of the channel for the connected probe.
c. In the Calibration section, click Calibrate Probe.
5. On MDO3000 and MDO/MSO/DPO4000B instruments:
Press the Channel Menu front panel button for the
channel that you connected the probe to.
Push the More button until Probe Setup is selected.
Push the Calibrate Probe button and follow the
on-screen instructions.
If the probe compensation fails, verify that the signal and
ground connections are secure at the Probe Comp connections.
Also check that the ground connection is secure at the probe
head, the rigid, MMCX or pogo tip is secured tightly in the
probe head, and the hook tip is securely connected to the tip.
Standard accessories
WARNING. To avoid electric shock when using the probe or
accessories, keep fingers behind the finger guard of probe
body and accessories.
Item Description
Probe tips – pogo (white) and
rigid (gray)
The white pogo tip is
pre-installed on the probe, and
is spring-loaded for compliant
testing of circuit boards.
Reorder Tektronix part numbers:
206-0610-xx (rigid tip)
206-0611-xx (pogo tip)
Insulator sleeve
Unscrew this sleeve to replace
the probe tips.
Reorder Tektronix part number
342-1194-xx
Hook tip
Press the hook tip onto the probe
tip and then clamp the hook onto
the circuit.
Rating: 300 V CAT II
Reorder Tektronix part number
013-0362-xx
Micro hook tip
Use this tip to access test points
in tight spaces. Press the hook
tip onto the probe tip and then
extend the pincers around the
circuit.
Rating: 300 V CAT II
Reorder Tektronix part number
013-0363-xx
Universal IC cap
Use this cap to prevent shorting
the probe tip between IC pins.
Press the cap on the probe tip
until it snaps on, and then spin
the cap to expose the probe tip
toward the IC lead.
Reorder Tektronix part number
013-0366-xx
Ground springs
To limit aberrations on high
frequency signals caused by
ground path inductance, bend
the spring to reach nearby
ground connections (<0.75 in,
long; <0.25 in, short).
Reorder Tektronix part numbers:
016-2028-xx (long, 2 ea.)
016-2034-xx (short, 2 ea.)
Ground lead, with alligator clip
Secure the lead to the probe
head ground and then to your
circuit ground.
Reorder Tektronix part number
196-3521-xx
Color bands
Use these bands to identify the
oscilloscope channel at the probe
head.
Reorder Tektronix part number
016-0633-xx (5 pairs)
Optional accessories
NOTE. The accessories shown below are available for the
probes and are rated ≤30 V unless indicated otherwise.
Accessory Part number
MMCX probe tip (gold) 1206-0663-xx
MMCX to 0.1-inch
(2.54 mm) square pin
adapter (blue), 0.025-inch
(0.635 mm) sq. pins
131-9717-xx
MMCX to 0.062inch
(1.57 mm) square
pin adapter (white),
0.016 - 0.018 inch
(0.4 - 0.46 mm) sq. pins
131-9677-xx
Electrical Y-Lead 196-3434-xx
MicroCKT
Tes t Ti p
206-0569-xx
BNC to Tip Adapter,
Unterminated
013-0367-xx
Circuit Board Test
Point/PCB Adapter
016-2016-xx
Chassis-Mount Probe
Test Jack
131-4210-xx
6” Clip-on Ground Lead 196-3198-xx
12” Alligator
Ground Lead
196-3512-xx
Wire, spool,
32 AWG
020-3045-xx
DUT Interface pin kit
with (qty. 20) 0.018 inch
(0.46 mm) round
solder-in pins
020-3169-xx
Probe tip tripod support
with living hinge, 2 each 2
352-1170-xx
Solder aid for 0.062-inch
(1.57 mm) pitch square
pins, 0.016 - 0.018-inch
(0.4 - 0.46 mm) sq. pins
003-1946-xx
1See Connecting the MMCX tip to the oscilloscope Probe Comp for connection
instructions.
2The tripod probe tip support is pictured with the probe tip and adapter attached.
Interchanging the Probe Tip
WARNING. To reduce the risk of shock, disconnect the
probe before changing the probe tips.
For optimal performance, do a probe compensation after the
tip has been replaced.
Connecting the MMCX tip to the oscilloscope Probe Comp
WARNING. To reduce the risk of shock, disconnect the
probe before connecting accessories.
Item Description
Connect the MMCX tip to
adapter 1
The MMCX adapter
(131-9717-xx) snaps onto
the MMCX tip.
Connect the Y–lead to MMCX
adapter 1
Push the Y–lead (196-3434-xx)
adapter into the MMCX adapter
until it is seated.
The signal input (red) connects
to the center of the MMCX
adapter.
Connect the MicroCKT test
tips to Y-lead
Push the Y-lead into the handles
of the MicroCKT test tips
(206-0569-xx).
Connect the MicroCKT test tips to Probe Comp terminals
Attach the two MicoCKT test tips to the Probe Comp terminals on the
ocsilloscope front panel.
1MMCX tip, adapter, and Y-lead is limited to 30 vrms, 42 Vpk, 60 VDC, and
OVT <500 Vpk.
TPP1000
1 GHz 10X Passive Probe
Instructions
x
*P071280903*
071-2809-03
Electrical and mechanical specifications
Characteristic Specification
Bandwidth (–3 dB) 1 GHz
System rise time (typical) <450 ps
System input capacitance Rigid and MMCX tip: 3.9 pF ±0.3 pF
Pogo pin tip: 5.1 pF ±0.5 pF
System attenuation accuracy 10:1 ±2.2%
Probe series resistance @DC 9.75 MΩ±0.5%
System input resistance @DC 10 MΩ±2%
Propagation delay ~5.67 ns
Maximum input voltage 300 VRMS CAT II 1
Cable length 1.3 m ±3 cm
1MMCX tip, adapter, and Y-lead is limited to 30 vrms, 42 Vpk, 60 VDC, and
OVT <500 Vpk.
Performance graphs
Environmental specifications
Characteristics Description
Temperature
Operating
Nonoperating
–15°Cto+65°C(+5°Fto+149°F)
–62 °C to +85 °C (–80 °F to +185 °F)
Humidity
Operating 5% to 95% relative humidity (%RH) up to
+30°C,5%to75%RHabove+30°Cupto
+65 °C. Noncondensing
Nonoperating 5% to 45% RH above +65 °C up to +85 °C.
Noncondensing
Altitude
Operating
Nonoperating
3.0 km (9,842 ft) maximum
12.2 km (40,000 ft) maximum
Certifications and compliances
Characteristics Description
EU
Directives
Compliance was demonstrated to the following
specification as listed in the Official Journal of the
European Communities:
Low Voltage Directive 2014/35/EU:
EN61010-031/A1: 2008
RoHS Directive 2011/65/EU
Measurement
Category
Product
Examples
CAT III: Distribution-level mains, fixed installation
CAT II: Local-level mains, appliances, portable
equipment
CAT I: Circuits not directly connected to mains.
Pollution
Degree 2
Do not operate in environments where cond-
uctive pollutants may be present (as defined in
IEC 61010-1). Rated for indoor use only.
Additional
Safety
Standards
UL61010-031;2010
CAN/CSA C22.2 No. 61010-031:07/A1:2010
IEC61010-031; IEC 61010-031/A1:2008
Equipment Recycling. This product complies
with the European Union’s requirements
according to Directive 2012/19/EU on waste
electrical and electronic equipment (WEEE). For
more information about recycling options, check
the Support/Service section of the Tektronix Web
site (www.tek.com/productrecycling).
Safety summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Using the probe or accessories in a manner not specified could
result in a shock or fire hazard.
To avoid fire or personal injury
Ground-Referenced Oscilloscope Use. Do not float the
reference lead of this probe when using with ground referenced
oscilloscopes (for example, MDO, MSO, and DPO series
oscilloscopes). The reference lead must be connected to earth
potential (0 V).
Connect and Disconnect Properly. Connect the probe output to
the measurement instrument before connecting the probe to the
circuit under test. Disconnect the probe input and the probe
reference lead from the circuit under test before disconnecting
the probe from the measurement instrument.
Avoid Electric Shock. To avoid injury or loss of life, do not
connect or disconnect probes or test leads while they are
connected to a voltage source.
Observe All Terminal Ratings. To avoid fire or shock hazard,
observe all ratings and markings on the product. Consult the
product manual for further ratings information before making
connections to the product.
Avoid Electric Shock. When using probe accessories, never
exceed the lowest rating of the probe or its accessory, whichever
is less, including the measurement category and voltage rating.
Avoid Electric Overload. To avoid injury or fire hazard, do not
apply potential to any input, including the reference inputs,
that varies from ground by more than the maximum rating for
that input.
Avoid Exposed Circuitry and Do not Operate Without Covers. Do
not touch exposed connections and components when power
is present.
Inspect The Probe And Accessories. Before each use, inspect
probe and accessories for damage (cuts, tears, defects in the
probe body, accessories, cable jacket, etc.). Do not use if
damaged.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols Terms in This Manual.
These terms may appear in this manual:
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols on the Product. These symbols may appear on the
product:
Contacting Tektronix
Web site: www.tektronix.com
Phone: 1-800-833-9200
Address: Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. B ox 50 0
Beaverton, OR 97077 USA
Email: techsupport@tektronix.com
Warranty information
For warranty information, go to http://www.tek.com/warranty.
Copyright © Tektronix, Inc. All rights reserved. www.tek.com

Other Tektronix Accessories manuals

Tektronix P5122 User manual

Tektronix

Tektronix P5122 User manual

Tektronix GeoProbe G10 Owner's manual

Tektronix

Tektronix GeoProbe G10 Owner's manual

Tektronix P6013 User manual

Tektronix

Tektronix P6013 User manual

Tektronix TriMode P7500 Series Manual

Tektronix

Tektronix TriMode P7500 Series Manual

Tektronix P5100A User manual

Tektronix

Tektronix P5100A User manual

Tektronix P7330 User manual

Tektronix

Tektronix P7330 User manual

Tektronix TMSSY2 mPGA479 User manual

Tektronix

Tektronix TMSSY2 mPGA479 User manual

Tektronix P7225 User manual

Tektronix

Tektronix P7225 User manual

Tektronix TPP0500 User manual

Tektronix

Tektronix TPP0500 User manual

Tektronix CT-6 User manual

Tektronix

Tektronix CT-6 User manual

Tektronix P6122 User manual

Tektronix

Tektronix P6122 User manual

Tektronix THDP0100 User manual

Tektronix

Tektronix THDP0100 User manual

Tektronix Trimode TDP7700 Series User manual

Tektronix

Tektronix Trimode TDP7700 Series User manual

Tektronix P5200A User manual

Tektronix

Tektronix P5200A User manual

Tektronix TPR1000 User manual

Tektronix

Tektronix TPR1000 User manual

Tektronix P6249 User manual

Tektronix

Tektronix P6249 User manual

Tektronix P6047 User manual

Tektronix

Tektronix P6047 User manual

Popular Accessories manuals by other brands

ZigBoat ZB204 owner's manual

ZigBoat

ZigBoat ZB204 owner's manual

ARC'TERYX AR-385a user manual

ARC'TERYX

ARC'TERYX AR-385a user manual

Aeotec MULTISENSOR 6 user guide

Aeotec

Aeotec MULTISENSOR 6 user guide

Optex RC-20U installation instructions

Optex

Optex RC-20U installation instructions

Johnson Controls 7351J Installation and maintenance instructions

Johnson Controls

Johnson Controls 7351J Installation and maintenance instructions

Baumer OHDM 16P5651 quick start guide

Baumer

Baumer OHDM 16P5651 quick start guide

Festo Span Series operating instructions

Festo

Festo Span Series operating instructions

X4-Life 701659 instruction manual

X4-Life

X4-Life 701659 instruction manual

SICK LRS4000 operating instructions

SICK

SICK LRS4000 operating instructions

Teac TC-SR(T)-G3 Instructions for use

Teac

Teac TC-SR(T)-G3 Instructions for use

Evenflo 630424 quick start guide

Evenflo

Evenflo 630424 quick start guide

Perry Electric 1PR6092 quick guide

Perry Electric

Perry Electric 1PR6092 quick guide

SUREHATCH SH60 user manual

SUREHATCH

SUREHATCH SH60 user manual

Panasonic FX-301-F7 instruction manual

Panasonic

Panasonic FX-301-F7 instruction manual

HJH MARDERSCHUTZ 737 user manual

HJH

HJH MARDERSCHUTZ 737 user manual

Ecodhome 01335-1450-00 installation manual

Ecodhome

Ecodhome 01335-1450-00 installation manual

Electro-Voice MI-1 Architects and engineers specifications

Electro-Voice

Electro-Voice MI-1 Architects and engineers specifications

OHAUS Defender T24PE user guide

OHAUS

OHAUS Defender T24PE user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.