Tektronix P6139B User manual

Revision A
500 MHz 10X Probes
The P6139B & P5050B probes are high impedance,
passive probes that are designed for use with Tektronix
ground-referenced oscilloscopes, including the
DPO/MSO/TDS 3000/4000/5000/7000 series oscilloscopes.
Both probes have a bandwidth of >500 MHz and 10X
attenuation. The P6139B probe has a compensation range
of 8 to 18 pF, while the P5050B probe has a compensation
range of 15 to 22 pF.
Connecting the Probe to the Oscilloscope
Connect the probe to the oscilloscope as shown below.
Compensating the Probe
Due to variations in oscilloscope input characteristics,
the low-frequency compensation of the probe may need
adjustment after moving the probe from one oscilloscope
channel to another.
If a 1 kHz calibrated square wave displayed at 1 ms/division
shows significant differences between the leading and
trailing edges, perform the following steps to optimize
low-frequency compensation:
1. Connect the probe to the oscilloscope channel that you
plan to use for your measurements.
2. Connect the probe to the probe compensation output
terminals on the oscilloscope front panel.
WARNING. To avoid electric shock, only connect to the
Probe Comp signal on the oscilloscope when making
this adjustment.
To avoid electric shock, only use the insulated adjustment
tool when making compensation adjustments.
3. Push AUTOSET or otherwise adjust your oscilloscope
to display a stable waveform.
4. Adjust the trimmer in the probe until you see a perfectly
flat-top square wave on the display. (See illustration.)
Standard Accessories
The accessories included with the probe are shown below.
WARNING. To avoid electric shock when using the probe
or accessories, keep fingers behind the finger guard of
probe body and accessories.
To reduce risk of shock, verify that the ground lead and
ground spring are fully mated before connecting the
probe to the circuit under test.
Item Description
Universal IC Cap
Use this cap to prevent shorting
the probe tip between IC pins.
Press the cap on the probe tip
until it snaps on, and then spin
the cap to expose the probe tip
toward the IC lead.
Reorder Tektronix part number
013-0366-xx
Hook tip
Press the hook tip on the probe
tip and then clamp the hook on
the circuit.
Rating: 300 V CAT II
Reorder Tektronix part number
013-0362-xx
Color bands
Use these bands to identify
the oscilloscope channel at the
probe head.
Reorder Tektronix part number
016-0633-xx (5 pairs)
Item Description
Ground lead, with alligator
clip
Attach the lead to the probe
head ground and then to your
circuit ground.
Reorder Tektronix part number
196-3521-xx
Ground spring
This spring minimizes
aberrations on high frequency
signals caused by ground
path inductance, giving you
measurements with good signal
fidelity.
Attach the spring to the ground
band on the probe tip. Bend the
spring in or out, up to ~0.75 in.
Reorder Tektronix part number
016-2028-xx
Adjustment tool
Use only this insulated tool for
compensation adjustments.
Reorder Tektronix part number
003-1433-xx
Optional Accessories
The accessories shown below are available for the probes
and are rated ≤30 V unless indicated otherwise.
Accessory Part number
MicroCKT Test Tip 206-0569-xx
Micro Hook TipRating: 300 V CAT II 013-0363-xx
BNC to Tip Adapter, Unterminated 013-0367-xx
Circuit Board Test Point/PCB Adapter 016-2016-xx
Chassis-Mount Probe Test Jack 131-4210-xx
6” Clip-on Ground Lead 196-3198-xx
12” Alligator Ground Lead 196-3512-xx
Ground Spring, Short 016-2034-xx
P6139B & P5050B
500 MHz 10X Passive Probes
Instructions
x
*P071271000*
071-2710-00
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Revision A
Replacing the Probe Tip
Order Tektronix part number 206-0635-xx (P6139B) or
206-0636-xx (P5050B). The insulator sleeve, part number
204-1226-xx, is reorderable and is common to both probes.
WARNING. Only qualified service personnel should
replace the probe tip. Disconnect the probe before
servicing. After replacing the tip, securely tighten the
insulator sleeve before using the probe.
Specifications
Table 1: Electrical and mechanical specifications
Characteristic Specification
Bandwidth DC to 500 MHz (–3 dB)
System attenuation accuracy 10:1 ±0.5% @DC
Compensation range P6139B: 8 pF–18 pF
P5050B: 15 pF–22 pF
System input resistance 10 MΩ±0.5% @DC
System input capacitance P6139B: <8 pF
P5050B: <11 pF
Propagation delay ~6 ns
Maximum tip input voltage 300 VRMS CAT II and DC
Cable length 1.3 m
Table 2: Environmental specifications
Characteristic Description
Temperature
Operating
Nonoperating
–15°C(+5°F)to+65°C(+149°F)
–62 °C to +85 °C (–80 °F to +185 °F)
Humidity
Operating 5% to 95% relative humidity (%RH) up to
+30 °C, 5% to 75% RH above +30 °C up
to +65 °C. Noncondensing
Nonoperating 5% to 45% RH above +65 °C up to +85 °C.
Noncondensing
Altitude
Operating
Nonoperating
3.0 km (10,000 ft) maximum
15 km (50,000 ft) maximum
Table 3: Certifications and compliances
Characteristic Description
EC
Declaration
of
Conformity
Compliance was demonstrated to the following
specification as listed in the Official Journal of
the European Communities:
Low Voltage Directive 2006/95/EC:
EN61010-031: 2008
CAT III: Distribution-level mains, fixed installation
CAT II: Local-level mains, portable equipment
Measurement
Category
Product
Examples CAT I: Circuits not directly connected to mains
Characteristic Description
Pollution
Degree 2
Do not operate in environments where cond–
uctive pollutants may be present (as defined in
IEC 61010-1). Rated for indoor use only.
Additional
Safety
Standards
UL61010-031;2010
CAN/CSA C22.2 No. 61010-031:07/A1:2010
IEC61010-031; IEC 61010-031/A1:2008
Equipment Recycling. This product complies
with the European Union’s requirements
according to Directive 2002/96/EC on waste
electrical and electronic equipment (WEEE). For
more information about recycling options, check
the Support/Service section of the Tektronix
Web site (www.tektronix.com).
Safety Summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected
to it. To avoid potential hazards, use this product only as
specified. Using the probe or accessories in a manner not
specified could result in a shock or fire hazard.
To Avoid Fire or Personal Injury
Ground-Referenced oscilloscope use. Do not float the
reference lead of this probe when using with ground
referenced oscilloscopes (for example, DPO, MSO, and
TDS series oscilloscopes). The reference lead must be
connected to earth potential (0 V).
Connect and disconnect properly. Connect the probe output
to the measurement instrument before connecting the probe
to the circuit under test. Disconnect the probe input and
the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid electric shock. To avoid injury or loss of life, do not
connect or disconnect probes or test leads while they are
connected to a voltage source.
Observe all terminal ratings. To avoid fire or shock hazard,
observe all ratings and markings on the product. Consult
the product manual for further ratings information before
making connections to the product.
Avoid electric shock. When using probe accessories, never
exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and
voltage rating.
Avoid electric overload. To avoid injury or fire hazard, do
not apply potential to any input, including the reference
inputs, that varies from ground by more than the maximum
rating for that input.
Avoid exposed circuitry and do not operate without
covers. Do not touch exposed connections and components
when power is present.
Inspect the probe and accessories. Before each use, inspect
probe and accessories for damage (cuts, tears, defects in
the probe body, accessories, cable jacket, etc.). Do not use
if damaged.
Do not operate in Wet/Damp conditions.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Safety Terms and Symbols Terms in This Manual.
These terms may appear in this manual:
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols on the product. These symbols may appear on
the product:
Contacting Tektronix
Web site: www.tektronix.com
Phone: 1-800-833-9200
Address: Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Email: [email protected]
Copyright © Tektronix, Inc. All rights reserved. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com

This manual suits for next models

1

Other Tektronix Measuring Instrument manuals

Tektronix TLA7012 User manual

Tektronix

Tektronix TLA7012 User manual

Tektronix P6460 User manual

Tektronix

Tektronix P6460 User manual

Tektronix BSX Series Installation instructions

Tektronix

Tektronix BSX Series Installation instructions

Tektronix BERTScope BSA85C Manual

Tektronix

Tektronix BERTScope BSA85C Manual

Tektronix TLA6402 Installation and maintenance instructions

Tektronix

Tektronix TLA6402 Installation and maintenance instructions

Tektronix 7D20 User manual

Tektronix

Tektronix 7D20 User manual

Tektronix RSA3303A User manual

Tektronix

Tektronix RSA3303A User manual

Tektronix RSA5100B series Reference guide

Tektronix

Tektronix RSA5100B series Reference guide

Tektronix 1720 User manual

Tektronix

Tektronix 1720 User manual

Tektronix VM700T User manual

Tektronix

Tektronix VM700T User manual

Tektronix VM700T Operating and maintenance manual

Tektronix

Tektronix VM700T Operating and maintenance manual

Tektronix TLA6400 Series Use and care manual

Tektronix

Tektronix TLA6400 Series Use and care manual

Tektronix P6021 User manual

Tektronix

Tektronix P6021 User manual

Tektronix DL-11 DELAY LINE User manual

Tektronix

Tektronix DL-11 DELAY LINE User manual

Tektronix TLA 700 Series Product manual

Tektronix

Tektronix TLA 700 Series Product manual

Tektronix WFM2300 Administrator Guide

Tektronix

Tektronix WFM2300 Administrator Guide

Tektronix TTR500 series User manual

Tektronix

Tektronix TTR500 series User manual

Tektronix KEITHLEY 8606 User manual

Tektronix

Tektronix KEITHLEY 8606 User manual

Tektronix P6231 User manual

Tektronix

Tektronix P6231 User manual

Tektronix RSA3408A User manual

Tektronix

Tektronix RSA3408A User manual

Tektronix WCA230A Operating and maintenance manual

Tektronix

Tektronix WCA230A Operating and maintenance manual

Tektronix FCA3000 Series Operating and maintenance manual

Tektronix

Tektronix FCA3000 Series Operating and maintenance manual

Tektronix KEITHLEY 2600B Series User manual

Tektronix

Tektronix KEITHLEY 2600B Series User manual

Tektronix 1L30 User manual

Tektronix

Tektronix 1L30 User manual

Popular Measuring Instrument manuals by other brands

MONTOLIT 71ML operating instructions

MONTOLIT

MONTOLIT 71ML operating instructions

DMMetering PRO-1TE Series user manual

DMMetering

DMMetering PRO-1TE Series user manual

ETS-Lindgren HI-3638 user manual

ETS-Lindgren

ETS-Lindgren HI-3638 user manual

Equinox Systems EQ-TM- 4001 user manual

Equinox Systems

Equinox Systems EQ-TM- 4001 user manual

Vega VEGASON 61 operating instructions

Vega

Vega VEGASON 61 operating instructions

Keysight Technologies N9041B Installation note

Keysight Technologies

Keysight Technologies N9041B Installation note

Enerdis mDIGI2-TAC instruction manual

Enerdis

Enerdis mDIGI2-TAC instruction manual

DeWalt DW074LR instruction manual

DeWalt

DeWalt DW074LR instruction manual

Galvanic Applied Sciences ProTech903W Operation manual

Galvanic Applied Sciences

Galvanic Applied Sciences ProTech903W Operation manual

Status Instruments DM3600U manual

Status Instruments

Status Instruments DM3600U manual

EzCAP VHSDigi ezcap180 manual

EzCAP

EzCAP VHSDigi ezcap180 manual

MSA ALTAIR 5X quick start guide

MSA

MSA ALTAIR 5X quick start guide

KROHNE GA24 Supplementary instructions

KROHNE

KROHNE GA24 Supplementary instructions

Blaupunkt GT320D Operating and installation instructions

Blaupunkt

Blaupunkt GT320D Operating and installation instructions

Thunder Laser NOVA Series Unified User's manual

Thunder Laser

Thunder Laser NOVA Series Unified User's manual

Schaller Messtechnik Humimeter BM1 user manual

Schaller Messtechnik

Schaller Messtechnik Humimeter BM1 user manual

Ono Sokki LV-1800 instruction manual

Ono Sokki

Ono Sokki LV-1800 instruction manual

Ankom A2000 Replacement manual

Ankom

Ankom A2000 Replacement manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.