Here you have to choose the TCP Server section from the upper menu. In the marked fields:
1. Write your server (PC) port and press Listen button;
2. In the Client connection status you will be able to see if a connection between server and FMB
device has started successfully;
3. In the Send field, you can write a message that is packed in Codec.12 format which will be sent to
the FM63XY device.
Step 4. Sending from server to external device over Hercules
When sending a message from Hercules, first you have to pack it in Codec.12 format. If you want to
send a message to an external device over FM63XY from the server, a packed message should be
pasted into the Send field in Hercules (Figure 2, marked field 3). The HEX format box should be
unchecked if the text is in HEX format (for example:
00000000000000260C01050000001e48656c6c6f2c206c657473207465737420544350206c696e6b20
6d6f64650100001aef etc.). When you press the Send button, you will see your message in the Sent
data field (Terminal). If the message is sent successfully to FM63XY you can check it in the Terminal
window.
Connect Port ½ cable one end to RS232 RX/TX cables on the FM63XY device and then connect the
USB side to the computer. Please find which port is used for Port ½ cable in the device manager.
Please select correct COM Port (1). In this case, we use COM21. Then press connects (2).
Open the Hercules application and just type your message in the marked field (3) and press the Send
button (4). If sent successfully, you will see it in Hercules Sent data field (Figure 4). For example test
text will be sent: Hello, lets test TCP link mode. In Codec.12 format it looks:
00000000000000260C01050000001e48656c6c6f2c206c657473207465737420544350206c696e6b20
6d6f64650100001aef