Teltonika FMB640 User manual

https://wiki.teltonika-gps.com/view/FMB640_Thermograph
FMB640 Thermograph
Main Page > EOL Products > FMB640 > FMB640 Manual > FMB640 Thermograph
Contents
1 Introduction
2 Supported Thermographs
3 RS-232 Interface
4 Installation guide
4.1 TouchPrint/TouchLog
4.2 Carrier Datacold 600
4.3 Euroscan
5 Configuration
5.1 DataCold Reefer
5.2 TK Transcan2 Reefer
5.3 Euroscan IO
5.4 TK Touchprint/Touchlog I/O
Introduction
With an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor
real-time information from freezer trailer thermographs. Each thermograph has an RS232
communication line where FMB640 devices can connect via COM1/COM2 port of the device. The
solution is easy to install and configure. This allows you to monitor the main information of the
freezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according
to your needs. For more information please refer to the installation manual below.
NOTE: this feature is available from FW ver. 01.02.23.Rev.00
Supported Thermographs
FMB640 can be connected to Euroscan, DataCold600, Transcan2, TouchPrint thermographs.
Refer to the table below to see which freezers use which thermograph:
Thermograph Type
Freezer Type Euroscan DataCold600 Transcan2 TouchPrint/TouchLog
Carrier + + - -
ThermoKing + - + +
RS-232 Interface
RS-232 supports full-duplex communication which means the data can be both sent and received at
the same time as they use separate transmission lines. Most of the modes are the same as for

FMB640. When entering Sleep or Deep sleep RS-232 will be powered off. FMB640 RS-232
connection diagram is shown in the figure below:
Installation guide
TouchPrint/TouchLog
TouchPrint pinout:
No configuration is necessary.
If the equipment does not receive information from the thermographer, the speed of the port
accessing the configuration menu:
Keep the blue and red buttons pressed at the same time. "Enter PIN code" is displayed on the
screen, enter pin "1111" by pressing the blue button four times. Travel for the options with the red
button.
The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched
to ON, keep scrolling through the options until you find Baud Rate> 9600. The value should be 9600,
otherwise, adjust the speed by moving the cursor with the ◄ and ► keys, and adjust the speed with
the keys ▲ and ▼.
TouchLog pinout:
AVL IDs for Touchprint:
Parameter
name
Input
1
Input
2
Input
3
Input
4
Input
5
Input
6
Setpoint
1
Setpoint
2
Setpoint
3

AVL ID 10695 10696 10697 10698 10699 10700 10701 10702 10703
Configuration: No configuration is necessary.
See ThermoKing Configuration.
Carrier Datacold 600
To properly use DataCold 600 with FMX640 these steps must be followed:
In FMX640 RS232 settings DataCold mode is selected and Baudrate set to 38400
Partner mode enabled on DataCold 600
To enable Partner mode on DataCold 600:
Press and hold the green button for 4 seconds1.
Insert password. Default password - 11112.
Press the blue button to open 11 communication settings3.
Press the green button to select edit action4.
11.1.0 Com1 Port settings should be opened, then press the green button again5.
Then search for Partner protocol and press the green button to accept changes6.
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage
DataCold 600 RS232 connection: Pinout of DataCold600
Available parameters (AVL IDs) with DataCold 600:
Parameter
name
Zone 1
Compartment
state
Zone 1
Compartment
mode
Zone 1
Return
Air
Sensor
Zone 1
Supply
Air
Sensor
Zone 1 Set
Temperature
Zone 1
Evaporator
temperature
Zone 2
Return
Air
Sensor
Zone 2
Supply
Air
Sensor
Zone 2 Set
Temperature
Zone 3
Compartment
state
Zone 3
Compartment
mode
Zone 3 Set
Temperature
AVL ID 10045 10046 10047 10048 10049 10050 10056 10057 10058 10063 10064 10067
Parameter
name
Speed
mode
Ambient Air
Temperature
Compressor
Config
Installation
Serial
Analog Input
1-3
Manufacturer
ID
Battery
State
Flags
Fuel
state
flags
Maintenance
1-5 Hours
Run
Mode
Error
Codes
Temperature
Probe 1-6
AVL ID 10071 10350 10353 10356 10468-10470 10472 10473 10474 10475-10479 10480 10639 10644-10649
Run mode explanation:
Run mode StartStop Continious CycleCentry Unknown/Now available
Value (HEX) 01 2 7

Fuel and Battery state flag explanation:
Fuel/Battery Flag Status Available Error Alarm Digital sensor
Enum (bit field) value 01 2 3
Euroscan
To properly use Euroscan with FMX640 these steps must be followed:
In FMX640 RS232 settings Euroscan mode is selected and Baudrate set to 38400
Partner mode enabled on Euroscan
To enable Partner mode on Euroscan :
Press and hold the green button for 4 seconds1.
Insert password. Default password - 11112.
Press the blue button to open 11 communication settings3.
Press the green button to select edit action4.
11.1.0 Com1 Port settings should be opened, then press the green button again5.
Then search for Partner protocol and press the green button to accept changes6.
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage
Euroscan RS232 connection: Pinout of DataCold600
Available parameters (AVL IDs) with Euroscan :
External
Sensor
Temperature
1
External
Sensor
Temperature
2
External
Sensor
Temperature
3
External
Sensor
Temperature
4
External
Sensor
Temperature
5
External
Sensor
Temperature
6
Digital
Sensor
1
Digital
Sensor
2
Digital
Sensor
3
Digital
Sensor
4
484 485 486 487 488 489 10464 10465 10466 10467
Configuration
Make sure the FMB640 device is configured to receive data from “Transcan2 Reefer”, "Touchprint
Reefer", "Euroscan: or "DataCold Reefer". To do this, enter the configurator window, select the
RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2
Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer", "Euroscan"or "DataCold Reefer",

Baudrate: Default)
DataCold Reefer
To configure "DataCold Reefer" I/O parameters, please select "Reefer IO":
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more
in-depth information, please refer to Reefer IO data sending parameters.
TK Transcan2 Reefer
To configure "Transcan2 Reefer" I/O parameters, please select "TK Transcom IO":
Data sending parameters (AVL ID) used for "Transcan2 " are these: 10683 - 10694. For more in-
depth information, please refer to Transcan IO data sending parameters
Euroscan IO
To configure "Euroscan refeer" I/O parameters select "Euroscan IO":
Data sending parameters (AVL ID) used for "Euroscan" are these: 484-489 and 10464-10467. For

more in-depth information, please refer to Euroscan IO data sending parameters.
TK Touchprint/Touchlog I/O
To configure "Touchprint Reefer" I/O parameters select "TK Touchprint IO":
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more
in-depth information, please refer to Touchprint IO data sending parameters.
Codec 8 Extended should be selected as the main data protocol in the “Protocol Settings” tab, which
is located in the “System” section.
Other manuals for FMB640
4
Table of contents