HIPswitch-75 Series
The HIPswitch-75 is a small form-factor
IoT edge gateway designed for non-
Industrial environments which facilitates
MODELS
Part Number Model Ethernet Ports Wi-Fi
PLF-0115-02 HIPswitch-75e 3 No
PLF-0122-01 HIPswitch-75w 3 Yes
Specication
Ethernet
Ports
3 x 10/100/1000 Mbps RJ-45
ports
Operating Temp 0° to 40° C
(32° to 104° F)
Controls 1x Micro USB console port Environment For indoor use only
Displays 1x Power LED
1x WiFi LED
1x Activity/Status LED
Dimensions W: 110mm (4.33”)
D: 84.5mm (3.33”)
H: 29.5mm (1.16”)
DC Power
Input
12V DC, 2A max
5.5×2.1mm power input
Weight 153 g (.337 lbs.)
Regulatory
Approvals
CE
(75e/w)
EN 55032:2015, EN 55035:2017, EN 55024:2010, EN 6100-3-
2:2014, EN 61000-3-3:2013, EN 60950-1:2006+A2:2013
CE RED
(75w)
EN 300 328, EN 301 893, EN 301 489-1,
EN 301 489-3, EN 301 489-17, EN 62311:2008
FCC
(75e)
Part 15B class B IC
(75e)
CAN ICES-3 (B)/
NMB-3(B)
FCCID
(75w)
2AE4M-HS75W IC ID
(75w)
20900-HS75W
Top and Front Panel Layouts
1. Activity/Status LED
2. WiFi LED
3. Power LED
4. Port 1 (default: shared network)
5. Port 2-3 (default: secure network)
6. USB (not supported)
private overlay networks between customer-provided equipment
and devices.

Safety and Warnings
Elevated Operating Ambient Temperature: If installed in a closed envi‐
ronment, make sure the operating ambient temperature is compatible
with the maximum ambient temperature specied by the manufacturer.
Reduced Air Flow: Make sure the amount of air ow required for safe operation of
the equipment is not compromised during installation.
1. Connect a computer to the HIPswitch-75 using the micro USB console port located on the
back of the HIPswitch.
2. Using a terminal (macOS, Linux) or terminal emulator (Windows), connect to the HIPswitch
using baud 115200.
3. At the login prompt, enter hipsh, then hipsh as the password.
4. At the hipsh prompt, enter conductor set https://<conductor address>:<port>
6. At the hipsh prompt, enter reboot
After rebooting, the HIPswitch should now be recognized in the Conductor UI.
Provisioning the HIPswitch-75
The Conductor is the central conguration and management
point for all HIPservices. For
provisioning, a HIPswitch must be able to locate the Conductor on your shared network. The
fastest method is to connect the HIPswitch via the console port.
Regulatory Information
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the
following two conditions: (1) This device may not cause interference; and (2) This device must
accept any interference, including interference that may cause undesired operation of the de‐
vice.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisee aux deux conditions suivantes: 1) l’appareil ne
doit pas produire de brouillage; 2) l’utilisateur de l’appareil doit accepter tout brouillage ra‐
dioelectrique subi, meme si le brouillage est susceptible d’en compromettre le fonction‐
nement."
Radiation Exposure: This equipment complies with FCC and ISED radiation exposure limits
set forth for an uncontrolled environment. This equipment should be installed and operated
with minimum distance of 20cm between the radiator and your body and must not be co-lo‐
cated or operating in conjunction with any other antenna or transmitter.
De
claration sur l'exposition aux rayonnements RF: L'autre utilise pour l'emetteur doit etre
installe pour fournir une distance de separation d'au moins 20 cm de toutes les personnes et
ne doit pas etre colocalise ou fonctionner conjointement avec une autre antenne ou un autre
emetteur.
Tempered Networks, Inc declares that the HIPswitch-75w is in compliance with
Directive 2014/53/EU. This device may be used in all EU member states subject to
the following condition: This device may only be used indoors.
The full text of the EU declaration of conformity is available at the following Internet
address: https://repo.tempered.io/DoC/75w

FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and canradiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be
installed and operated with minimum distance between 20cm the radiator your body: Use
only the supplied antenna.
The use of the 5150 – 5250 MHz band is restricted to indoor use only. This restriction
will be applied in all member states.

ICCaution:
ThisdevicecomplieswithIndustryCanadaslicence-exemptRSSs.Operation issubjecttothe
followingtwoconditions:
(1)Thisdevicemaynot causeinterference;and
(2)Thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesired
operation of thedevice.
Tomaintain compliancewithRFexposureguidelines,thisequipmentshould beinstalledand
operatedwitha minimum distanceof 20cm betweentheradiatorand yourbody.
Leprésentappareil estconformeauxCNRd'IndustrieCanada applicablesaux appareilsradio
exempts delicence.L'exploitation estautoriséeaux deuxconditionssuivantes:
(1) l'appareil nedoit pasproduiredebrouillage,et
(2) l'utilisateurdel'appareil doitacceptertoutbrouillageradioélectriquesubi,mêmesile
brouillageestsusceptibled'encompromettrelefonctionnement.
Pourmaintenirla conformitéaux directivesd'expositionaux radiofréquences, cet équipement
doit être installéetutiliséavecunedistanceminimalede20cm entreleradiateuretvotrecorps.
This manual suits for next models
4
Table of contents
Other TEMPERED Gateway manuals
Popular Gateway manuals by other brands

Moxa Technologies
Moxa Technologies Mgate MB3660 user manual

MatchX
MatchX M2 Pro user guide

2N
2N Mobile Audio Gateway installation and connection

Beijer Electronics
Beijer Electronics korenix JetWave 3220v3 Series user manual

Innoband
Innoband 6000-B1 user manual

Allied Telesis
Allied Telesis AT-RG613TX Series user manual