tempmate GS2 User manual


empower your supply chain.
3V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
1. Introduction ............................................................................................................................................................................................ 3
2. Intended Use ...........................................................................................................................................................................................3
3. tempmate.®-GS2 Model ................................................................................................................................................................... 4
4. Device Description ................................................................................................................................................................................6
5. Display Description .............................................................................................................................................................................. 7
6. Quick Start Guide ................................................................................................................................................................................. 8
7. Operation and Usage..........................................................................................................................................................................10
8. FAQ ......................................................................................................................................................................................................... 14
How can I start the tempmate.®-GS2 device? ............................................................................................................ 14
I have pressed the start button but still the device is not started. ........................................................................ 14
How can I know that the device is started and recording parameters? ............................................................. 14
I am not able to see the data in cloud what should I do? ......................................................................................... 14
My shipment has reached the destination but still I do not see any data in the cloud. ................................ 14
CanIreconguretheparametersafterthedeviceisstarted?...............................................................................15
How can I receive alarm threshold alerts? .................................................................................................................... 15
WillIreceivetherealtimealertsforanalarmthresholdbreach?.........................................................................15
Can I start and stop the device more than once? ....................................................................................................... 15
Whatdoestherecordingdurationofthedevicemean?...........................................................................................15
Whatdoestheshelflifemean?.........................................................................................................................................16
Can I connect an external sensor to the tempmate.®-GS2 T and TH model? ................................................ 16
Can I remove the external sensor? ................................................................................................................................... 16
How can a device be stopped? .......................................................................................................................................... 16
Can I recharge the battery? ................................................................................................................................................. 16
Can the battery be replaced? .............................................................................................................................................. 16
9.MainTechnicalSpecications
tempmate.®-GS2 T ............................................................................................................................................................... 18
tempmate.®-GS2 TH ............................................................................................................................................................ 19
tempmate.®-GS2 TE ............................................................................................................................................................. 20
ContactInformation...............................................................................................................................................................................21
TableofContents
The tempmate.®-GS2 is designed and developed to
attach to a shipment to measure relevant parameters
like temperature, Humidity, light and location. The de-
vice records and sends data to the tempmate Cloud
based on the transmission interval. The device provi-
des real time visibility to the shipment and traceability.
1. Introduction 2. Intended Use
The tempmate.®-GS2 is designed to be attached to
shipments and record relevant parameters as men-
tioned in the Data Sheet. Any use or operation which
requiresspecicrequirementsandstandardswhich
aren’t explicitly mentioned in the data sheet must be
validated and tested on customer’s own responsibility.

empower your supply chain.
5V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
3. tempmate.®-GS2 Models
One-way
Temperature
Rel. humidity
Localisation
Light
Extended measuring range

empower your supply chain.
7V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
1
6
7
3
5
2
4
8
9
10
11 12
4. Device Description 5. Display Descriprion
1.Signal icon 7. Alarm status
2. Probe mark 8. Start-up delay
3.MAX&MIN 9. Temperature unit
4.Charging icon 10. Humidity unit
5.Battery icon 11. Alarm type
6.Record icon 12. Temperature value
Start Button Stop Button
LCD
LED Indicator

empower your supply chain.
9V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
6. Quick Start Guide
The tempmate.®-GS2 comeswithabundledpackageofhardware,connectivityandcloudaccess.Ausercan
easilystartusingthedeviceandaccessthemeasuredreportincloudbyfollowingthesesimplesteps.
STEP 1 Create a tempmate cloud account
Tocongureandaccessthedevicetheuserneedatempmatecloudaccount.Thetempmatecloudaccountis
freeofcostandanyusercancreateone.Theonlyprerequisiterequiredtocreatinganaccountisavalidemail
id. The user can create a tempmate cloud account by clicking on this link
https://web.tempmate.cloud/login
andfollowingtheinstructions.
STEP 2 Add device to tempmate cloud account
Theusercanaddnewdeviceinthetempmatecloudplatformbyclickingon“AddNewDevice”andcustom
congurethedevicebyfollowingtheinstructionsinthecloudplatform.Toaddthedevicetotheaccount,the
usershouldhaveaccesstothe14characterserialnumberofthedevice(mentionedonthebacksideofthe
device, e.g.: GS2XXXXXXXXXXX).
STEP 3 Start the device
The tempmate.®-GS2 devicecanbestartedbypressingtheleftgreenbuttoncontinuouslyformorethan5
sec.Thestartofthedeviceisconrmedby10timesashingofBlueLED,additionallythestartcanbeconr-
med by the record sign on the display screen.
STEP 4 Attach the device to the shipment
Once the device is started it can be placed in the shipment. Additionally the device can be attached to the ship-
mentusingthe“3Msticker”onthebacksideofthedevice.
STEP 5 Track the shipment
Theshipmentcanbetrackedandmonitoredthroughthetempmatecloudplatform.Additionally,reportscanbe
viewedandexportedinPDFandCSVformatfromthecloudplatform.
STEP 6 Stopping the device
Once the shipment arrives the destination the device can be stopped by pressing continuously the red stop
buttonformorethan5sec.Thestopofthedeviceisconrmedby10timesashingofRedLED,additionally
thestopcanbeconrmedbytherecordsignNOTvisibleonthedisplayscreen.Optionally,thedevicecan
beconguredforstopfromthecloudplatformremotelyorbyconnectingtotheUSBport.

empower your supply chain.
11V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
7. Operation and Usage
STEP 1 StatusCheckfornotstarteddevice
Pressoncethegreen“START”buttonandthescreenwilldisplaytheword“SLEEP”indicatingthattheloggeris
currently in not started state.
STEP 2 Starting the device
Continuouslypressthegreen“START”buttonformorethan5sec.
Thescreenstartsashingtheword“START”indicatingtheloggerstart.Atthistime,theiconisdisplayedon
theleftsideofthescreen,indicatingthattheloggerhasbeenturnedon.
STEP 3 Start-up delay
If“Startupdelay”isset,oncetheloggeristurnedonitentersthestart-updelayphase.Theiconisdisplayedon
the right side, indicating that the logger is in the start-up delay phase.
STEP 4 Recordinginformation
Afterenteringtherecordingstate,theiconwillnolongerbedisplayed,andthealarmstatuswillbedisplayedin
thelowerleftcornerofthescreen:
the temperature is normal.
the threshold has been exceeded.
HI the high threshold has been exceeded.
LO the low threshold has been exceeded.

empower your supply chain.
13V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
STEP 5 How to stop recording
Continuouslypressthered“STOP”buttonformorethan5sec.
Whenthescreenstartsashingpleasereleasethebuttonandtheloggerstops.
STEP 6 Viewnalinformation
Afterstopping,pressoncethe”START”buttontoviewlocaltimeofthedevice,theMAXandtheMIN
temperature data recorded.
Optionally,theloggercanbeconguredforstopfromthecloudplatformremotelyorbyconnectingtotheUSB
port.
STEP 7 Get PDF report
PDFdatareportcanalsobeobtainedanytime,anywhereontempmatecloudplatform.
STEP 8 Charging
ThebatteryofthetempmateGS2canbecharged.
Ifthebatteryislowbeforeuse,itcanbedirectlyconnectedtothemicroUSBinterfaceforcharging(Pleaseuse
5V charger). When charging, the charging icon will be displayed.
Optionally the PDF report can be downloaded locally by connecting the logger to the computer using a USB
cable*(*notsuppliedwiththelogger).
7. Operation and Usage

empower your supply chain.
15V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
8. FAQ
How can I start the tempmate.®-GS2 device?
Thedevicecanbestartedwiththegreenstartbuttonbypressingitcontinuouslyformorethan5sec.
I have pressed the start button but still the device is not started. What should I do?
Thedeviceisconguredtostartwhenthestartbuttonispressedmorethan5secandlessthan40sec.So,
thebuttonpresstimeshouldbe“5sec<buttonpresstime<40sec”.Theupperlimitof40sechasbeensetto
preventaccidentalstartofthedeviceduringtransportation.
How can I know that the device is started and recording parameters?
Theproperstartofthedeviceisconrmedby10timesashingofBlueLED,additionallythestartcanbeconr-
med by the record sign on the display screen.
I am not able to see the data in cloud what should I do?
Therecordeddatawillbetransmittedtothetempmatecloudbasedonthe“TransmissionInterval”setbythe
userwhileconguringthedevice.AdditionallythedeviceusesGSMSIMconnectivitytosenddatatothecloud
platformandincasethedeviceisoperatedwhereinthereisnonetworkconnectivitythennodatawillbeuploa-
dedtothecloudplatform.
My shipment has reached the destination but still I do not see any data in the cloud.
ThetransmittingofdatatotheclouddependsontheGSMconnectivityandincasetherewasnoconnectivity
establishedthendatawillnotbetransmittedbuttheuserhasthepossibilitytolocallydownloadthereportfrom
thedeviceusingtheUSBport(butpleasenotethatthelatest24200datapointswillbelocallyavailableonthe
device).
CanIreconguretheparametersafterthedeviceisstarted?
Yes,theusercanrecongureorchangethedevicecongurationanytimefromthecloudportalbyclickingthe
“Edit”tabagainstaspecicdevice.
How can I receive alarm threshold alerts?
TheusercanconguretoreceivealarmalertsthroughEmailand/orSMSinthetempmatecloudportal.
WillIreceivetherealtimealertsforanalarmthresholdbreach?
Yes,therstalarmthresholdbreachistriggeredonrealtime.
Can I start and stop the device more than once?
Yes,thetempmate.®-GS2canbestartedandstopped3timesorrecordforamaximumof90daysfromthe
rststart,whichevercomesrst.
Whatdoestherecordingdurationofthedevicemean?
Recordingdurationorruntimeisthedurationforwhichthedevicecancontinuouslyoperateandrecordpa-
rameters.ThestandardrecordingdurationfortempmateGS2Lithiumvariantis90days(withstandardlog
intervalof10min.andtransmissionintervalof240min)andforNonLithiumBatteryis60days(withstandard
logintervalof10min.andtransmissionintervalof240min.)

empower your supply chain.
17V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
Whatdoestheshelflifemean?
ThetempmateGS2Lithiumvarianthasashelflifeof12monthsandnon-Lithiumvarianthasashelflifeof6
monthsfromthedateofproduction.ItismentionedastheExpirydate“EXP”onthebacksideofthedevice.
ThatmeansthattheusercanstartandusethedeviceanytimebeforethementionedExpirydate.
Can I connect an external sensor to the tempmate.®-GS2 T and TH model?
No, presently there is no possibility to connect an external sensor to the tempmate.®-GS2 T and TH model. The
tempmate.®-GS2TEcomeswithaninbuiltexternalsensorwhichcanbeusedfordifferentapplications.
Can I remove the external sensor?
Thetempmate.®-GS2TEcomeswithanexternalsensoranditisrmlyxedintothedeviceandcannotbe
removed or replaced.
How can a device be stopped?
Thedevicecanbestoppedbycontinuouslypressingtheredstopbuttonformorethan5sec.Optionally,the
devicecanbeconguredforstopfromthecloudplatformremotelyorbyconnectingtotheUSBport.
Can I recharge the battery?
Thedevicebatteryisfullychargedandreadytousebutincasebecauseoflongerstorageofthedeviceifthe
batteryisshowinglowbeforeuse,itcanbechargedbyconnectingittothemicroUSBport(Pleaseuse5V
charger).
Can the battery be replaced?
The device battery is inbuilt and cannot be replaced.

empower your supply chain.
19V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
9. MainTechnicalSpecicationstempmate.®-GS2 T
Battery type All the variation available in Lithium and Non-Lithium option
Temperature Range -30°C to +70°C
Temperature Accuracy ±0.3°C(-10°C~45°C),±0.5°C(Other)
Temperature Resolution 0.1°C
Humidity Range Available with the TH Model
Humidity Accuracy Available with the TH Model
Resolution Humidity Available with the TH Model
Ambient Light 0to10000lx/Accuracy0.01lx
Resolution Ambient Light 0.01 lx
Local Data Storage Capacity 24,200valuesforTemperatureandLight
Shelf-Life LithiumBatterydevices:12monthsshelflife
Non-LithiumBatterydevices:6monthsshelflife
Battery Lithium Battery: Li-ion Polymer Battery 2400mAh
Non-Lithium Battery: Ni-MH Battery 2000 mAh
External Sensor Available with the TE Model
Log Interval Userdened:1min.to60min.(10min.asstandardsettingprecongured)
Transmission Interval Userdened:10min.to1440min.(60min.asstandardsettingprecongured)
Recording Duration
LithiumBattery:90days(withstandardlogintervalof10min.andtransmission
intervalof240min.)
NonLithiumBattery:60days(withstandardlogintervalof10min.andtransmis-
sionintervalof240min.)
Startup Mode Bydefaultstartbybutton
Stop Mode Bydefaultstopbybutton(optionallyviatheUSBportorthecloudplatform)
Start Delay Userdened:0min.to1440min.(Nostartdelayasstandardsettingprecongured)
Protection Class IP65
Display MultifunctionDisplay
Dimensions 103x64x23mmforLithiumand
103x64x30mmforNon-Lithium
Weight 130gforLithiumand
175gforNon-Lithium
Certications CE, EN12830, EMC, RoHS, FCC
ValidationCerticate Available as PDF in the Cloud
Software tempmate.®-Cloud
Report Generation ReadableintheCloudandlocallyinthedevicethroughtheUSB2.0interface
Password Protection Cloud Password Protection
Connectivity LTE 4G cat 1 with 2G Fallback
Location LBS - GSM Localization
AlarmConguration Upto6Alarmfortemperature+upto3Alarmforlight,AlarmDelayProgramm-
able
Programmable Via Cloud
Alarm Type Single/Cumulative
Recommended Storage Temperature +15°C to + 25°C
Case Material Polycarbonate
9. MainTechnicalSpecicationstempmate.®-GS2 TH
Battery type All the variation available in Lithium and Non-Lithium option
Temperature Range -30°C to +70°C
Temperature Accuracy ±0.3°C(-10°C~45°C),±0.5°C(Other)
Temperature Resolution 0.1°C
Humidity Range 0% to 100%rH
Humidity Accuracy ±3%(20%~80%),±5%(Other)
Resolution Humidity 1%
Ambient Light 0to10000lx/Accuracy0.01lx
Resolution Ambient Light 0.01 lx
Local Data Storage Capacity 24,200valuesforTemperature,HumidityandLight
Shelf-Life LithiumBatterydevices:12monthsshelflife
Non-LithiumBatterydevices:6monthsshelflife
Battery Lithium Battery: Li-ion Polymer Battery 2400mAh
Non-Lithium Battery: Ni-MH Battery 2000 mAh
External Sensor Available with the TE Model
Log Interval Userdened:1min.to60min.(10min.asstandardsettingprecongured)
Transmission Interval Userdened:10min.to1440min.(60min.asstandardsettingprecongured)
Recording Duration
LithiumBattery:90days(withstandardlogintervalof10min.andtransmission
intervalof240min.)
NonLithiumBattery:60days(withstandardlogintervalof10min.andtransmis-
sionintervalof240min.)
Startup Mode Bydefaultstartbybutton
Stop Mode Bydefaultstopbybutton(optionallyviatheUSBportorthecloudplatform)
Start Delay Userdened:0min.to1440min.(Nostartdelayasstandardsettingprecongured)
Protection Class IP65
Display MultifunctionDisplay
Dimensions 103x64x23mmforLithiumand
103x64x30mmforNon-Lithium
Weight 130gforLithiumand
175gforNon-Lithium
Certications CE, EN12830, EMC, RoHS, FCC
ValidationCerticate Available as PDF in the Cloud
Software tempmate.®-Cloud
Report Generation ReadableintheCloudandlocallyinthedevicethroughtheUSB2.0interface
Password Protection Cloud Password Protection
Connectivity LTE 4G cat 1 with 2G Fallback
Location LBS - GSM Localization
AlarmConguration Upto6Alarmfortemperature+upto6AlarmforHumidity+upto3Alarmfor
light, Alarm Delay Programmable
Programmable Via Cloud
Alarm Type Single/Cumulative
Recommended Storage Temperature +15°C to + 25°C
Case Material Polycarbonate

empower your supply chain.
21V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
9. MainTechnicalSpecicationstempmate.®-GS2 TE
Battery type All the variation available in Lithium and Non-Lithium option
Temperature Range -200°C to +100°C
Temperature Accuracy ±0.5°C(-10°C~45°C),±1°C(Other)
Temperature Resolution 0.1°C
Humidity Range Available with the TH Model
Humidity Accuracy Available with the TH Model
Resolution Humidity Available with the TH Model
Ambient Light Available with the Tand TH Model
Resolution Ambient Light Available with the Tand TH Model
Local Data Storage Capacity 24,200valuesforTemperature
Shelf-Life LithiumBatterydevices:12monthsshelflife
Non-LithiumBatterydevices:6monthsshelflife
Battery Lithium Battery: Li-ion Polymer Battery 2400mAh
Non-Lithium Battery: Ni-MH Battery 2000 mAh
External Sensor PT100(cablelength:1m,lengthofprobeis6cmlength,4mmindiameter,
sensor tip: stainless steel)
Log Interval Userdened:1min.to60min.(10min.asstandardsettingprecongured)
Transmission Interval Userdened:10min.to1440min.(60min.asstandardsettingprecongured)
Recording Duration
LithiumBattery:90days(withstandardlogintervalof10min.andtransmission
intervalof240min.)
NonLithiumBattery:60days(withstandardlogintervalof10min.andtransmis-
sionintervalof240min.)
Startup Mode Bydefaultstartbybutton
Stop Mode Bydefaultstopbybutton(optionallyviatheUSBportorthecloudplatform)
Start Delay Userdened:0min.to1440min.(Nostartdelayasstandardsettingprecongured)
Protection Class IP65
Display MultifunctionDisplay
Dimensions 103x64x23mmforLithiumand
103x64x30mmforNon-Lithium
Weight 130gforLithiumand
175gforNon-Lithium
Certications CE, EN12830, EMC, RoHS, FCC
ValidationCerticate Available as PDF in the Cloud
Software tempmate.®-Cloud
Report Generation ReadableintheCloudandlocallyinthedevicethroughtheUSB2.0interface
Password Protection Cloud Password Protection
Connectivity LTE 4G cat 1 with 2G Fallback
Location LBS - GSM Localization
AlarmConguration Upto6Alarmfortemperature,AlarmDelayProgrammable
Programmable Via Cloud
Alarm Type Single/Cumulative
Recommended Storage Temperature +15°C to + 25°C
Case Material Polycarbonate

empower your supply chain.
23V1.0-02/2022-DE · Technische Änderungen und Irrtümer vorbehalten
CONTACT INFORMATION
Do you have any questions? Please contact us - our
experienced team will be happy to support you.
+49 7131 6354 0

tempmate GmbH
Edisonstr. 25
74076 Heilbronn, Germany
Tel. +49-7131-6354-0
www.tempmate.com