TEQSAS LAP-TEQ PLUS User manual

Operating Manual

Table of contents
2 V-04/2018
Table of contents
1Before you get started… .................................................................. 4
1.1 Intended use ....................................................................................... 4
1.2 What do the symbols used here mean? ............................................. 4
2For your safety .................................................................................. 6
2.1 General safety information ................................................................. 6
2.2 About laser beams .............................................................................. 7
2.3 Workplace safety ................................................................................ 7
2.4 Electrical safety .................................................................................. 7
2.5 Human safety ..................................................................................... 8
2.6 Handling of battery-powered devices ................................................. 8
2.7 Safety information for battery chargers .............................................. 8
2.8 Service ................................................................................................ 9
2.9 Special instructions concerning the device ........................................ 9
3Description of product ................................................................... 11
3.1 Scope of delivery .............................................................................. 11
3.2 Your device at a glance .................................................................... 12
4First operation ................................................................................ 14
4.1 Charging the battery ......................................................................... 14
4.2 Connection........................................................................................ 16
4.3 First operation ................................................................................... 18
5Operation ......................................................................................... 19
5.1 Power on/off ..................................................................................... 19
5.2 Display texts ..................................................................................... 20

Table of contents
LAP-TEQ PLUS 3
6Cleaning and care........................................................................... 21
7Malfunctions and troubleshooting ............................................... 22
7.1 Service centre ................................................................................... 23
7.2 Observe ambient conditions ............................................................. 23
8Calibration ....................................................................................... 24
9Storage ............................................................................................ 29
10 Disposal ........................................................................................... 30
10.1 Disposal of batteries/rechargeable batteries .................................... 30
10.2 Removing the battery ....................................................................... 31
11 Technical data ................................................................................. 32
12 Declaration of Conformity ............................................................. 34

Before you get started…
4 V-04/2018
1 Before you get started…
1.1 Intended use
With LAP-TEQ PLUS you can measure the inclination of speaker systems.
LAP-TEQ PLUS measures the horizontal angle between its longitudinal axis
and the earth’s surface. This provides information on the horizontal orientation
of the speaker element.
Any other use not described in this operating manual is unauthorised misuse.
The manufacturer will not be liable for damages incurred from such misuse.
Never use the device as a display device or in public transport (road traffic,
aviation, etc.).
1.2 What do the symbols used here mean?
Danger notices and warnings are clearly designated in the operating manual.
The following symbols are used:
Danger!
Immediate danger of death or injury!
Immediately dangerous situation that will result in death or
severe injuries.
Warning!
Probable danger of death or injury!
Generally dangerous situation that can result in death or
severe injuries.

Before you get started…
LAP-TEQ PLUS 5
Caution!
Potential danger of injury!
Dangerous situation that can result in injuries.
Attention!
Danger of damage to device!
Situation that can result in material damage.
Notice
Information provided for better understanding of the processes.

For your safety
6 V-04/2018
2 For your safety
Warning!
Failure to comply with the safety information and
instructions can cause electric shock, fire and/or
severe injuries.
► Read all safety information and instructions.
2.1 General safety information
Store all safety information and instructions for future reference. The term
device used in the safety information refers to mains-powered devices
(with a mains cable) and to battery-powered devices (without a mains
cable).
Danger of death and accident for small children and children! Never leave
children unattended with the packaging material and the product. There is
a danger of suffocation from the packaging material and danger of death
from strangulation. Children often underestimate dangers. Always keep
children away from the product. The product is not a toy.
For safe use of this device the user of the device must have read and
understand this operating manual prior to the first use of the device.
If you sell or pass on the device, be sure to include this operating manual
with the device.
This device is not intended for use by persons (including children) with
impaired physical, sensory or mental capacities or insufficient experience
and/or insufficient knowledge, unless they are supervised by a person who
is responsible for their safety or receive instructions from that person on
how to use the device.
The device may be used only if it is in perfect working order and
completely mounted. If the device or a component thereof is defective, it
must be taken out of operation and repaired by a specialist or properly
disposed of.

For your safety
LAP-TEQ PLUS 7
Use the device only for the purpose for which it is intended.
Keep children away from the device! Store the device safely out of the
reach of children and unauthorised persons.
Use and store the device only within the permissible ambient conditions
(temperatures, humidity, etc.).
2.2 About laser beams
Do not look into the beam, even at large distances.
Never point the measuring beam at people, other living beings or reflective
surfaces.
Commercially available laser glasses do not provide protection against the
dangers of laser beams. They only help to better recognise the laser
beam.
2.3 Workplace safety
Keep your workplace clean and well lighted. Disorder and unlighted
workplaces can cause accidents.
Observe the applicable workplace and accident prevention regulations for
your country.
Do not use the electrical device in potentially explosive environments
containing flammable liquids, gases or dusts. Electric tools generate
sparks, which can ignite dust or vapours.
2.4 Electrical safety
In dry environments it is possible for static electricity to occur. In dry
rooms, touch a metal object to discharge static electricity before operating
the device.
Do not misuse the cables to carry or suspend the device or to pull the plug
from the electrical outlet. Keep cables away from heat, oil, sharp edges or
moving device components. Damaged or tangled cables increase the risk
of damage to the device.
If you use the device outdoors, use only extension cables that are suitable
for outdoor use. The use of an extension cable that is suitable for outdoor
use reduces the risk of damage to the device.

For your safety
8 V-04/2018
2.5 Human safety
Be attentive, pay attention to what you are doing, and use common sense
while working. Do not use the device if you are tired or under the influence
of drugs, alcohol or medications. One moment of carelessness during use
of the device can result in serious injuries. The sensor must be bolted
firmly to the flying frame or secured by suitable means against falling.
2.6 Handling of battery-powered devices
Use only chargers approved by the manufacturer with the specifications
indicated on the type plate of the rechargeable battery. The use of other
chargers can cause the danger of injuries and material damage from
exploding batteries.
Use the device only with the intended batteries. The use of other batteries
can cause injuries and the risk of fire.
Do not expose the battery to heat, flame, water or moisture. There is a
danger of explosion.
Vapours can escape from a damaged battery or through improper use of
the battery. Provide for adequate ventilation and in case of symptoms
consult a physician. The vapours can irritate your respiratory passages
and cause diseases.
2.7 Safety information for battery chargers
Keep the charger away from rain or moisture. Penetration of water into a
charger increases the risk of electric shock.
Keep the charger clean. A dirty charger involves the risk of electric shock.
Check the charger, including the cable and plug, before each use. Do not
use the charger if you detect signs of damage.
Do not open the charger yourself; have it repaired only by a qualified
specialist, and only using original replacement parts. Damaged chargers,
cables and plugs increase the risk of electric shock.
Do not operate the device on a flammable surface (such as paper, textiles,
etc.) or in a flammable environment. There is a risk of fire from the heat
generated by the charger.
Supervise children and do not allow children to play with the charger.
Children and persons with mental or physical impairments may use the

For your safety
LAP-TEQ PLUS 9
charger only under supervision or if they have been instructed in its use.
Careful instruction reduces the possibility of incorrect operation and
injuries.
2.8 Service
Have your device repaired only by qualified specialists, and only using
original replacement parts. This will ensure the long-term safety of the
electric tool.
Provide for adequate lighting when working with the device. Poor visibility
can increase the risk of accidents.
Use only accessories that are intended especially for use with this device
and recommended by the manufacturer. The fact that you can attach
accessories to the device is no guarantee for their safe and trouble-free
use.
The device can show signs of wear over time.
The use of non-approved accessories can result in damage or wear that is
not covered by the warranty.
2.9 Special instructions concerning the device
Do not use the device in potentially explosive areas or in the vicinity of
flammable liquids or gases!
Paint and labels can cause moving parts to stick, therefore impairing
correct operation.
If you are have an allergic reaction to the paint or metal parts of the
device, the result may be itching, eczemas or swelling of the skin. If this is
the case, discontinue using the device and consult a physician.
Broken glass or plastic can cause injuries. Have the device repaired in the
service centre.
Do not allow the device to fall or expose it to shocks.
The device or parts of it can become damaged from falling, bending or
deformation.
Magnetic fields can cause the device to malfunction or the battery to
discharge.

For your safety
10 V-04/2018
The device features safeguards to limit the emitted laser beam: Do not
make any modifications to the optical system.
This device is classified as a class 3R laser product in accordance with the
international standard IEC 60825. It operates with a visible laser beam,
which is not dangerous in normal operation.
Do not remove or cover symbols located on your device. Illegible
information must be replaced immediately.
Read and comply with the operating manual prior to operating the
device.
Danger of eye injuries!
Never look directly into the laser beam.

Description of product
LAP-TEQ PLUS 11
3 Description of product
3.1 Scope of delivery
1x: LAP-TEQ Display PLUS (display unit)
2x: LAP-TEQ Sensor PLUS (sensor unit)
1x: Mains USB charger
1x: USB charge cable
1x: Calibration cable
1x: Safety information
1x: Transport case

Description of product
12 V-04/2018
3.2 Your device at a glance
1. LAP-TEQ Display PLUS
2. Display
3. Power button
4. Calibration button
5. Charge state indicator
6. USB charge socket
7. Socket for XLR cable
8. LAP-TEQ Sensor PLUS
9. Opening in pressure compensation membrane
10. Laser beam exit
11. Base plate with mounting plate
12. Socket for XLR cable
13. Calibration cable

Description of product
LAP-TEQ PLUS 13
A complete LAP-TEQ PLUS angle measuring system consists of a display unit
and at least one sensor unit.
The sensor unit is designed for mounting on the topmost element of a line
array or of the bumper and measures the horizontal angle between its
longitudinal axis and the earth’s surface. This provides information on the
horizontal orientation of the speaker element and/or of the entire array.
The laser beam of the sensor unit is used for visually checking the area that is
supplied with sound. This allows you to determine whether the height of the
speaker system is optimally adjusted in order to distribute sound to a spectator
stand or a balcony.
If the laser beam hits a projection surface at a short distance, in addition to the
actual laser cross you will also be able to see a square window and several
points in extension to the cross axis. These artefacts are no longer visible with
the normal working distances of the system and do not constitute a defect.
The products LAP-TEQ Display, LAP-TEQ Sensor, LAP-TEQ Display PLUS
and LAP-TEQ Sensor PLUS are mutually compatible and can be operated
together in any combination.
LAP-TEQ Sensor is limited to operation with the base plate oriented
downward.
The calibration of a sensor unit from the display unit is possible only with the
combination LAP-TEQ Display PLUS and LAP-TEQ Sensor PLUS.
For calibration of LAP-TEQ Sensor PLUS without LAP-TEQ Display PLUS
please contact your sales partner.
Compatibility overview
Operation Calibration Operation Calibration
Display Yes Internal Yes No 1
Display PLUS Yes Internal Yes Yes
1 Contact service partner

First operation
14 V-04/2018
4 First operation
4.1 Charging the battery
The battery must be charged before using the device for the first time.
If no charger is connected, the display will show the charge state of the battery
when the device is switched on.
Attention!
Danger of damage to device
► Never deep discharge the battery.
Notice
The lithium-polymer battery can be charged at any time without
reducing the life of the battery. Interrupting the charging
process will not damage the battery.
Notice
When the battery is fully charged the mains USB charger
automatically switches to trickle charge. The battery can remain
permanently in the charging station.
Notice
The battery will discharge if the device is not used for an
extended period. In this case, it must be charged before use.
Please note that the battery will reach its full capacity only after
being fully discharged and charged several times.
Attention!
Danger of damage to device!
Forced or incorrect connection of the charging cable can
damage the multi-functional socket or other parts of the
device.
► Connect the correct end of the cable to the device.

First operation
LAP-TEQ PLUS 15
► Plug the USB charging cable (1) into the USB socket (2) on the display
unit.
► Plug the mains USB charger (3) into a type F socket or Euro socket.
When the device is switched on the charge process is indicated by a blue
arrow on the display.
The charge state is indicated by the indicator light (4):
Red LED = charging
Green LED = fully charged
► Terminate the charging process when the battery is charged.
► Disconnect the mains USB charger from the power supply as long as you
are not using it.

First operation
16 V-04/2018
4.2 Connection
Attention!
Danger of damage to device!
Moisture and liquids can damage the components or
electronic circuits in the device.
► Do not switch the device on if it is damp.
► If the device is already switched on, switch it off.
► If the device cannot be switched off, allow it to dry in
this state.
► Dry the device with a dry cloth and take it to the service
centre.
Attention!
Danger of damage to device
► Never insert pointed objects into the opening of the
pressure compensation membrane on the sensor.
Attention!
Danger of damage to device
► All components are maintenance free. Never open the
device; otherwise, the warranty will be voided.

First operation
LAP-TEQ PLUS 17
► Connect the display unit (1) and a sensor unit (3) using a standard 3-pin
XLR cable (2).
There is no limit to the number of sensor units that can be connected
successively to a display unit. For example, three sensor units can be used to
check the correct orientation of a left and right PA system, as well as a centre
cluster. Alternatively, one sensor unit can be attached permanently to each
bumper.
To function correctly, the display unit must be connected to a sensor unit using
a standard XLR connection cable. The sensor units are supplied with power by
means of the XLR cable. There are no rechargeable batteries or other
batteries in the sensor unit.
If the cable between the display and the sensor unit is longer than 75 m, this
will reduce the brightness of the laser. However, the measuring function will
not be affected.
For a distance greater than 75 m, you must use an XLR cable with a larger
cross section than 0.22 mm². This will reduce the voltage drop along the cable
route.

First operation
18 V-04/2018
Notice
The calibration cable included with the device can also be used
for a function check. Use of the calibration cable alone does not
start the calibration process.
► For mounting the sensor units, use the flange holes (1) on the bottom of
the housing.
For secure mounting on a bumper without a special LAP-TEQ holder, you can
use the optional TEQSAS LAP-TEQ magnetic holder. The sensor must be
bolted firmly to the flying frame or secured by suitable means against falling.
4.3 First operation
The sensor units are calibrated at the factory so that the base plate has to be
oriented downward. To use the sensor unit in a different position, it must be
recalibrated. Four positions are possible (90° grid on the longitudinal axis), see
page 24.
For the first-time use the base plate must be positioned downward.

Operation
LAP-TEQ PLUS 19
5 Operation
5.1 Power on/off
Check the condition of the device:
► Check for visible defects.
► Check to make sure that all parts of the device are firmly mounted.
Warning!
Danger of eye injuries from laser beams!
If the laser beam hits the eyes via optical devices, this can
result in irreparable damage.
► Never look into the laser or direct the laser beam onto
reflecting surfaces!
► Make sure that no one is within the effective range of the laser.
► Power on: Press the “Power” button for about 3 seconds.
If the system has started up correctly, the green laser lights up and the current
angle measurement is displayed.
The angle measurement is refreshed every 2 seconds. This integrated feature
is necessary to prevent the last digit in the display from changing constantly,
which could result for example from wind movement.
Notice
Pressing the “CAL” button on the display unit during operation
does not switch the sensor unit to calibration mode. Instead, a
short guide to calibration is displayed. The display automatically
switches back to the angle measurement after a few seconds.
► Power off: Press the “Power” button again.

Operation
20 V-04/2018
5.2 Display texts
If no cable or sensor unit or a defective cable is
connected to the display unit, the warning “no sensor”
appears on the display when the display unit is switched
on: Establish a correct connection between the display
unit and the sensor unit.
If the word “over” appears on the display, the
permissible measurement range of +/- 50° was
exceeded. This measurement range is sufficient for
practical application.
If three dashes appear on the display, the sensor unit is
being used in a position for which it was not calibrated.
After switching off the power the last measured reading
is written to the internal memory of the display unit.
When it is switched on again this reading appears in the
bottom line of the display. This facilitates the comparison
of identical horizontal alignment of the left and right PA
system.
Table of contents
Popular Measuring Instrument manuals by other brands

Eaton
Eaton EMV600 operating instructions

Siemens
Siemens SITRANS F FUE950 quick start guide

Applent Instruments
Applent Instruments AT381x user guide

LaserLiner
LaserLiner PowerCross-Laser 3 manual

LaserLiner
LaserLiner RangeXtender RX 30 operating instructions

KROHNE
KROHNE BM 700 Installation and operating instructions