manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Termoplus
  6. •
  7. Measuring Instrument
  8. •
  9. Termoplus DT-8806 User manual

Termoplus DT-8806 User manual

1. IRSensor
2. LCDDisplay
3. Modeselection:body/ambient
4. DownButton
5. UpButton
6. MODEButton
7. MeasurementTrigger
8. BatteryCover
7. DEVICE CONSTRUCTION
4
DT-8806
PYROMETER Version 2.0
USER MANUAL / WARRANTY
8. CONFIGURATION
I.Measuringmode
TheNon-contactBodyInfraredThermometerisspeciallydesignedtotakethebodytemperatureof
ahumanbeing.Forthis,usetheBodymode.MeasurementrangeforBodymode:32-42,5 C(86-
108 F).
You canalso usethethermometertomeasurethetemperature ofan areaor anobject, food,liquid,
orroomtemperature.Forthis,usetheSurfacemode.MeasurementrangeforSurfacemode:0-60
C(32-140 F).
II.Choosing TheTemperatureUnit °C/°F-F1function
Press “MODE” button for 2 seconds, the screen displays: F1. Select “DOWN” for Celsius degrees
or“UP”forFahrenheitdegrees.
III.AlarmSetup-F2Menu
Press “MODE” touch for 2 seconds, the screen displays: F1. Press twice “MODE” touch to get F2.
Select“UP”toincreasethethresholdby0.1°C(0.1°F)or“DOWN”todeuceitby0.1°C(0.1°F).
Thealarmthresholddefaultis38°C(100.4°F).
IV.Pyrometer display calibration/TotalDifference(This functionis onlyeffectictive in Body
mode-bodytemperaturemeasurement)
ToadjustthetotalvariationofyourNon-ContactBodyInfraredThermometer,press“MODE”button
for 2 seconds, the screen displays: F1. Press “MODE” button two times to get F3. Select “UP” to
increase the difference by 0.1 °C (0.1 °F), “DOWN”to reduce it by 0.1 °C (0.1 °F). Temperature
value can be changed in: -3,0...3,0 °C range. In the cases of seasonal or environment changes a
verificationandadjustmentshouldbecarriedout.
V.BuzzerON/OFF- F4(F3)Menu
Press“MODE”buttonfor2seconds,thescreendisplays:F1.Pressthree(two)times“MODE”
ButtontogetF4(F3).
Select“UP” to open the buzzer ( asound icon is displayed on the LCDC screen), press “DOWN”to
stopit(theicondissapear).
°
°
° °
Non-Contact Forehead IR Thermometer is designed for body surface and forehead temperature
measurementforinfantsandadultswithoutcontacttohumanbody.
Non-Contact Forehead IR Thermometer can also be used to measure the temperature of a baby-
bottleorbath,orroomtemperature(byusingtheSurfaceTempfunction).
Pyrometer measuring range:
- ambient temperature: 0,0...60,0°C
- body temperature: 32,0...42,5°C
Display Resolution: 0,1°C
Accuracy: ±0,3°C
Measuring distance: 5...15cm
Display: LCD with backlight
Automatic Data Hold & Auto power off: after 7 sec of idleness
Unit selection: °C / °F
Buzzer: indicating about a measurement and alarm threshol exceeding
Functions:
- last 32 measurements memorizing
- measurements calibration in: -3...3°C range
Dimensions/weight: 128x74x36 mm / 125g
Power supply: DC 3V ( 2 x 1,5V battery )
Operation environment: 0°C÷50°C, <85% RH
Equipment: batteries, case, user manual
This appliance conforms to the following standards:
EN 980: Graphic symbols for use in the labeling of medical devices
EN 1041: Information supplied by the manufacturer with medical devices
EN 60601-1: General requirements for safety
EN60601-1-2: General requirements for safety Collateral standard Electromagnetic
compatibility
3. USE
Aim towards the forehead from a distance of 5 cm (2in), press the measuring key, the
temperature is displayed immediately. Making sure there is no hair, perspiration, cosmetic or
cap covered on the forehead.
When the room temperature is significant difference, or there is perspiration on the forehead,
You can take the temperature behind the ear lobe. Making sure there is no hair, perspiration,
cosmetic or cap covered.
Attention !!!
- For the first use or when inserting new batteries wait between 10 minutes for the warm-up of the
apparatusandwheninsertingthenewbatteries.
- If the device is not used for a long time, once you turn it on again, the device will test the room
temperaturefirstandwilldelayturningonforoneortwoseconds,
1. GENERAL DESCRIPTION
2. TECHNICAL SPECIFICATIONS
4.BODY TEMPERATURE MEASUREMENT (BODY)
Body temperature measuring range is 32,0
The temperature of the human body varies throughout the day. It can also be influenced by
numerousexternalfactors:age,sex,typeandthicknessofskin...
Temperatureaccordingtotheage:
0-2years: 36,4 ...38,0
Oral: 35,5 ...37,5
°C - 42,5°C. If the measurement value is not within a
range,thedisplaycanindicatesfollowingcommunicates:
HI-whenthetemperatureexceeds42,5°C
Lo-whenthetemperatureisbelow32,0°C
°C °C
3-10years: 36,1°C...37,8°C
11-65years: 35,9°C...37,6°C
>65years: 35,8°C...37,5°C
Normaltemperatureindifferentpartsofbody:
Forehead: 35,5°C...37,6°C
Ear: 35,8°C...38,0°C
°C °C
Axilliary:: 34,7°C...37,3°C
5. DISPLAY
1. Ambienttemperaturemeasurement
2. Bodytemperaturemeasurement
3. Digitalreadout
4. BatteryCondition
5. Measurementnumber
6. Savedmeasurement
7. Unit
8. AlarmSymbol
6. DATA READOUT
Turn on the unit with button no.7 “ measurement trigger”. Then pass between the stored data
pressing3or4button.

Popular Measuring Instrument manuals by other brands

Milwaukee MC110 manual

Milwaukee

Milwaukee MC110 manual

Full Gauge Controls EnergyLOG plus quick start guide

Full Gauge Controls

Full Gauge Controls EnergyLOG plus quick start guide

Bosch LR10 Operating/safety instructions

Bosch

Bosch LR10 Operating/safety instructions

General tools RHMG700DL user manual

General tools

General tools RHMG700DL user manual

FineTek ECP2 Operation manual

FineTek

FineTek ECP2 Operation manual

Exotek Instruments MC-460 user manual

Exotek Instruments

Exotek Instruments MC-460 user manual

Seca 515 Instructions for use for doctors and assistants

Seca

Seca 515 Instructions for use for doctors and assistants

Musical Fidelity M8xtt Instructions for use

Musical Fidelity

Musical Fidelity M8xtt Instructions for use

BREWFERM COBRA pH pen manual

BREWFERM

BREWFERM COBRA pH pen manual

PTI TorqTraQ Operator's manual

PTI

PTI TorqTraQ Operator's manual

Super Systems eFlo 2.0 Operation manual

Super Systems

Super Systems eFlo 2.0 Operation manual

Polimaster PM1703GNA-II Operation manual

Polimaster

Polimaster PM1703GNA-II Operation manual

Tecsis P2112 operating instructions

Tecsis

Tecsis P2112 operating instructions

Ametek 5000 Instrument manual

Ametek

Ametek 5000 Instrument manual

YARL DGTAL user guide

YARL

YARL DGTAL user guide

Environmental Express Oakton 300 Series instruction manual

Environmental Express

Environmental Express Oakton 300 Series instruction manual

Sierra Monitor Corporation 3240-01 user manual

Sierra Monitor Corporation

Sierra Monitor Corporation 3240-01 user manual

HP 86908 manual

HP

HP 86908 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.