1. IRSensor
2. LCDDisplay
3. Modeselection:body/ambient
4. DownButton
5. UpButton
6. MODEButton
7. MeasurementTrigger
8. BatteryCover
7. DEVICE CONSTRUCTION
4
DT-8806
PYROMETER Version 2.0
USER MANUAL / WARRANTY
8. CONFIGURATION
I.Measuringmode
TheNon-contactBodyInfraredThermometerisspeciallydesignedtotakethebodytemperatureof
ahumanbeing.Forthis,usetheBodymode.MeasurementrangeforBodymode:32-42,5 C(86-
108 F).
You canalso usethethermometertomeasurethetemperature ofan areaor anobject, food,liquid,
orroomtemperature.Forthis,usetheSurfacemode.MeasurementrangeforSurfacemode:0-60
C(32-140 F).
II.Choosing TheTemperatureUnit °C/°F-F1function
Press “MODE” button for 2 seconds, the screen displays: F1. Select “DOWN” for Celsius degrees
or“UP”forFahrenheitdegrees.
III.AlarmSetup-F2Menu
Press “MODE” touch for 2 seconds, the screen displays: F1. Press twice “MODE” touch to get F2.
Select“UP”toincreasethethresholdby0.1°C(0.1°F)or“DOWN”todeuceitby0.1°C(0.1°F).
Thealarmthresholddefaultis38°C(100.4°F).
IV.Pyrometer display calibration/TotalDifference(This functionis onlyeffectictive in Body
mode-bodytemperaturemeasurement)
ToadjustthetotalvariationofyourNon-ContactBodyInfraredThermometer,press“MODE”button
for 2 seconds, the screen displays: F1. Press “MODE” button two times to get F3. Select “UP” to
increase the difference by 0.1 °C (0.1 °F), “DOWN”to reduce it by 0.1 °C (0.1 °F). Temperature
value can be changed in: -3,0...3,0 °C range. In the cases of seasonal or environment changes a
verificationandadjustmentshouldbecarriedout.
V.BuzzerON/OFF- F4(F3)Menu
Press“MODE”buttonfor2seconds,thescreendisplays:F1.Pressthree(two)times“MODE”
ButtontogetF4(F3).
Select“UP” to open the buzzer ( asound icon is displayed on the LCDC screen), press “DOWN”to
stopit(theicondissapear).
°
°
° °
Non-Contact Forehead IR Thermometer is designed for body surface and forehead temperature
measurementforinfantsandadultswithoutcontacttohumanbody.
Non-Contact Forehead IR Thermometer can also be used to measure the temperature of a baby-
bottleorbath,orroomtemperature(byusingtheSurfaceTempfunction).
Pyrometer measuring range:
- ambient temperature: 0,0...60,0°C
- body temperature: 32,0...42,5°C
Display Resolution: 0,1°C
Accuracy: ±0,3°C
Measuring distance: 5...15cm
Display: LCD with backlight
Automatic Data Hold & Auto power off: after 7 sec of idleness
Unit selection: °C / °F
Buzzer: indicating about a measurement and alarm threshol exceeding
Functions:
- last 32 measurements memorizing
- measurements calibration in: -3...3°C range
Dimensions/weight: 128x74x36 mm / 125g
Power supply: DC 3V ( 2 x 1,5V battery )
Operation environment: 0°C÷50°C, <85% RH
Equipment: batteries, case, user manual
This appliance conforms to the following standards:
EN 980: Graphic symbols for use in the labeling of medical devices
EN 1041: Information supplied by the manufacturer with medical devices
EN 60601-1: General requirements for safety
EN60601-1-2: General requirements for safety Collateral standard Electromagnetic
compatibility
3. USE
Aim towards the forehead from a distance of 5 cm (2in), press the measuring key, the
temperature is displayed immediately. Making sure there is no hair, perspiration, cosmetic or
cap covered on the forehead.
When the room temperature is significant difference, or there is perspiration on the forehead,
You can take the temperature behind the ear lobe. Making sure there is no hair, perspiration,
cosmetic or cap covered.
Attention !!!
- For the first use or when inserting new batteries wait between 10 minutes for the warm-up of the
apparatusandwheninsertingthenewbatteries.
- If the device is not used for a long time, once you turn it on again, the device will test the room
temperaturefirstandwilldelayturningonforoneortwoseconds,
1. GENERAL DESCRIPTION
2. TECHNICAL SPECIFICATIONS
4.BODY TEMPERATURE MEASUREMENT (BODY)
Body temperature measuring range is 32,0
The temperature of the human body varies throughout the day. It can also be influenced by
numerousexternalfactors:age,sex,typeandthicknessofskin...
Temperatureaccordingtotheage:
0-2years: 36,4 ...38,0
Oral: 35,5 ...37,5
°C - 42,5°C. If the measurement value is not within a
range,thedisplaycanindicatesfollowingcommunicates:
HI-whenthetemperatureexceeds42,5°C
Lo-whenthetemperatureisbelow32,0°C
°C °C
3-10years: 36,1°C...37,8°C
11-65years: 35,9°C...37,6°C
>65years: 35,8°C...37,5°C
Normaltemperatureindifferentpartsofbody:
Forehead: 35,5°C...37,6°C
Ear: 35,8°C...38,0°C
°C °C
Axilliary:: 34,7°C...37,3°C
5. DISPLAY
1. Ambienttemperaturemeasurement
2. Bodytemperaturemeasurement
3. Digitalreadout
4. BatteryCondition
5. Measurementnumber
6. Savedmeasurement
7. Unit
8. AlarmSymbol
6. DATA READOUT
Turn on the unit with button no.7 “ measurement trigger”. Then pass between the stored data
pressing3or4button.

Popular Measuring Instrument manuals by other brands

Hanna Instruments HI97736 instruction manual

Hanna Instruments

Hanna Instruments HI97736 instruction manual

ATAGO 4555 instruction manual

ATAGO

ATAGO 4555 instruction manual

Status Instruments DM4000U manual

Status Instruments

Status Instruments DM4000U manual

LDG M-600 Operation manual

LDG

LDG M-600 Operation manual

Rae ppbRAE 3000 user guide

Rae

Rae ppbRAE 3000 user guide

FujiFilm LAS-3000 Specifications

FujiFilm

FujiFilm LAS-3000 Specifications

Intex Truline ALD30 Operation manual

Intex

Intex Truline ALD30 Operation manual

GW Instek GSP-818 Series Programming manual

GW Instek

GW Instek GSP-818 Series Programming manual

TESA TESA-hite Magna 400 instruction manual

TESA

TESA TESA-hite Magna 400 instruction manual

Elforlight HPG Series manual

Elforlight

Elforlight HPG Series manual

Keithley 2182 user manual

Keithley

Keithley 2182 user manual

NCI INSPEKTOR CTC INS7005 manual

NCI

NCI INSPEKTOR CTC INS7005 manual

Kleinwächter EFM 255 manual

Kleinwächter

Kleinwächter EFM 255 manual

Scarlet Tech WindPro user guide

Scarlet Tech

Scarlet Tech WindPro user guide

Keysight Technologies N432A user guide

Keysight Technologies

Keysight Technologies N432A user guide

Siemens ACCESS 9340 Reference manual

Siemens

Siemens ACCESS 9340 Reference manual

Minebea CSD-903-73 instruction manual

Minebea

Minebea CSD-903-73 instruction manual

Hach Ultra ORBISPHERE 3625 Operator's manual

Hach Ultra

Hach Ultra ORBISPHERE 3625 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.