TGE TGWS10-24 User manual

*Please read the manual before installation
Professional Wind & Solar Hybrid Controller Manual

1. Notes :
Thank you very much for purchasing our controller, please read the user manual carefully before installation and
use the product and keep it with due care.
Receive the product should first check whether the controller is damaged during the transportation. If you
found the problem, please contact our company or the transport company immediately.
The installation must be done by experienced technicians .The process must be strictly in accordance with
the user manual to ensure that the product can work properly.
Controller should avoid long-term corrosive gas and moist environment. Do not put this product in wet, rain,
exposure, severe dust, shock, corrosion and strong electromagnetic interference environment.
Keep children away from equipment.
Do not open the controller to repair it by yourself.
2. Catalogue
3 Technical Specification………………………………………………………………………… 3
4 Universal Function..………………………………………………………………………… ….7
5 Optional Function..……………...…………………..............................................................8
6 Design & Dimension .......................................................................................................10
7 System Schematic...........................................................................................................12
8 Installation ……………………………………………………. .............................................12
9 Electrical Connection.......................................................................................................13
10 Menu Operation ..…………………………………………………………………………….13
10.1 Buttons ...................................................................................................................13
10.2 Default interface......................................................................................................14
10.3 Main menu interface................................................................................................15
10.4 System interface......................................................................................................16
10.5 Wind information .....................................................................................................17
10.6 Solar information .....................................................................................................18
10.7 Date time .................................................................................................................18
11 PC Software Introduction……………………………………………………………………...19
12 The Warranty & Maintenance…………………………………………………………..........23

3. Technical Specification
3
Item No.
TGWS10-24
TGWS10-48
Rated Battery Voltage
24V
48V
Rated Wind Turbine Power
1kW
Maximum Wind Turbine Input Power
1.5kW
Rated Solar Charge Current
10A
Over-discharge Voltage
20.4V(adjustable)
40.8V(adjustable)
Over-discharge Recovery Voltage
23.0V(adjustable)
46.5V(adjustable)
Over-charge Voltage
29.4V (adjustable)
58.8V(adjustable)
Over-charge Recovery Voltage
26.4V(adjustable)
52.8V(adjustable)
Floating Voltage
27V (adjustable)
54V(adjustable)
Dump-load Start Voltage
100V(adjustable)
100V(adjustable)
Dump-load Start Rotate Speed
500RPM(adjustable)
Wind Turbine Charging Voltage
10V(adjustable)
20V(adjustable)
Wind Turbine Charging Mode
MPPT and PWM
Solar Charging Mode
PWM
Control Dump-load Mode
Over rotate speed limiting, Over voltage limiting,Over current limiting ,PWM
Display Mode
LCD
Display Parameters
wind power , wind voltage , wind current , wind turbine rotate speed ,PV
power , PV voltage , PV current , battery voltage , battery power ,charge
current, over voltage ,under voltage ,system state ,etc
Working Temperature & Humidity
-20~+55°C/35~85%RH(Without Condensation)
Quiescent Power Drain
<3W
Protection Function
Solar reverse-charging protection , solar reverse-connection
battery over charge protection, battery over-discharge
battery reverse-connection protection,
wind turbine automatic brake, wind turbine manual brake
Communication (Optional)
RS232 or RS485
Storage (Optional )
USB data logging
Controller Size (L*W*H)
423 *450*175MM
Package Size (L*W*H)
510*545*250MM
Gross Weight
17KGS

4
Item No.
TGWS14-24
TGWS15-48
TGWS20-96
TGWS20-120
TGWS20-220
TGWS20-240
Rated Battery Voltage
24V
48V
96V
120V
220V
240V
Rated Wind Turbine Power
2kW
Maximum Wind Turbine
Input Power
3kW
Rated Solar Charge
Current
10A
Over-discharge Voltage
20.4V(adjust
able)
40.8V
(adjustable)
80.0V
(adjustable)
102V
(adjustable)
185V
(adjustable)
204V
(adjustable)
Over-discharge Recovery
Voltage
23.0V(adjust
able)
46.5V
(adjustable)
92.0V
(adjustable)
115V
(adjustable)
210V
(adjustable)
230V
(adjustable)
Over-charge Voltage
29.4V
(adjustable)
58.8V
(adjustable)
115.0V
(adjustable)
144V
(adjustable)
265V
(adjustable)
288V
(adjustable)
Over-charge Recovery
Voltage
26.4V(adjust
able)
52.8V
(adjustable)
105.0V
(adjustable)
130V
(adjustable)
240V
(adjustable)
260V
(adjustable)
Floating Voltage
27V
(adjustable)
54V
(adjustable)
110.0V
(adjustable)
135V
(adjustable)
250V
(adjustable)
270V
(adjustable)
Dump-load Start Voltage
100V
(adjustable)
100V
(adjustable)
200V
(adjustable)
200V
(adjustable)
300V
(adjustable)
300V
(adjustable)
Dump-load Start Rotate
Speed
500RPM(adjustable)
Wind Turbine Charging
Voltage
10V
(adjustable)
20V
(adjustable)
40V
(adjustable)
50V
(adjustable)
100V
(adjustable)
100V
(adjustable)
Wind Turbine Charging
Mode
MPPT and PWM
Solar Charging Mode
PWM
Control Dump-load Mode
Over rotate speed limiting, Over voltage limiting,Over current limiting ,PWM
Display Mode
LCD
Display Parameters
wind power , wind voltage , wind current , wind turbine rotate speed ,PV power , PV voltage , PV
current , battery voltage , battery power ,charge current, over voltage ,under voltage ,system
state ,etc
Working Temperature &
Humidity
-20~+55°C/35~85%RH(Without Condensation)
Quiescent Power Drain
<3W
Protection Function
Solar reverse-charging protection , solar reverse-connection
battery over charge protection, battery over-discharge
battery reverse-connection protection,
wind turbine automatic brake, wind turbine manual brake
Communication (Optional)
RS232 or RS485
Storage (Optional )
USB data logging
Controller Size (L*W*H)
423 *450*175MM
Package Size (L*W*H)
510*545*250MM
Gross Weight
17KGS

5
Item No.
TGWS20-48
TGWS20-96
TGWS20-120
TGWS20-220
TGWS20-240
Rated Battery Voltage
48V
96V
120V
220V
240V
Rated Wind Turbine Power
2kW
Maximum Wind Turbine Input
Power
3kW
Rated Solar Charge Current
10A
Over-discharge Voltage
40.8V
(adjustable)
80.0V
(adjustable)
102V
(adjustable)
185V
(adjustable)
204V
(adjustable)
Over-discharge Recovery
Voltage
46.5V
(adjustable)
92.0V
(adjustable)
115V
(adjustable)
210V
(adjustable)
230V
(adjustable)
Over-charge Voltage
58.8V
(adjustable)
115.0V
(adjustable)
144V
(adjustable)
265V
(adjustable)
288V
(adjustable)
Over-charge Recovery Voltage
52.8V
(adjustable)
105.0V
(adjustable)
130V
(adjustable)
240V
(adjustable)
260V
(adjustable)
Floating Voltage
54V
(adjustable)
110.0V
(adjustable)
135V
(adjustable)
250V
(adjustable)
270V
(adjustable)
Dump-load Start Voltage
100V
(adjustable)
200V
(adjustable)
200V
(adjustable)
300V
(adjustable)
300V
(adjustable)
Dump-load Start Rotate Speed
500RPM(adjustable)
Wind Turbine Charging Voltage
20V
(adjustable)
40V
(adjustable)
50V
(adjustable)
100V
(adjustable)
100V
(adjustable)
Wind Turbine Charging Mode
MPPT and PWM
Solar Charging Mode
PWM
Control Dump-load Mode
Over rotate speed limiting, Over voltage limiting,Over current limiting ,PWM
Display Mode
LCD
Display Parameters
wind power , wind voltage , wind current , wind turbine rotate speed ,PV power , PV
voltage , PV current , battery voltage , battery power ,charge current, over
voltage ,under voltage ,system state ,etc
Working Temperature &
Humidity
-20~+55°C/35~85%RH(Without Condensation)
Quiescent Power Drain
<3W
Protection Function
Solar reverse-charging protection , solar reverse-connection
battery over charge protection, battery over-discharge
battery reverse-connection protection,
wind turbine automatic brake, wind turbine manual brake
Communication (Optional)
RS232 or RS485
Storage (Optional )
USB data logging
Controller Size (L*W*H)
423 *450*175MM
Package Size (L*W*H)
510*545*250MM
Gross Weight
17KGS

6
Item No.
TGWS30-48
TGWS30-96
TGWS30-120
TGWS30-220
TGWS30-240
Rated Battery Voltage
48V
96V
120V
220V
240V
Rated Wind Turbine Power
3kW
Maximum Wind Turbine Input
Power
4.5kW
Rated Solar Charge Current
10A
Over-discharge Voltage
40.8V
(adjustable)
80.0V
(adjustable)
102V
(adjustable)
185V
(adjustable)
204V
(adjustable)
Over-discharge Recovery
Voltage
46.5V
(adjustable)
92.0V
(adjustable)
115V
(adjustable)
210V
(adjustable)
230V
(adjustable)
Over-charge Voltage
58.8V
(adjustable)
115.0V
(adjustable)
144V
(adjustable)
265V
(adjustable)
288V
(adjustable)
Over-charge Recovery Voltage
52.8V
(adjustable)
105.0V
(adjustable)
130V
(adjustable)
240V
(adjustable)
260V
(adjustable)
Floating Voltage
54V
(adjustable)
110.0V
(adjustable)
135V
(adjustable)
250V
(adjustable)
270V
(adjustable)
Dump-load Start Voltage
100V
(adjustable)
200V
(adjustable)
200V
(adjustable)
300V
(adjustable)
300V
(adjustable)
Dump-load Start Rotate Speed
500RPM(adjustable)
Wind Turbine Charging
Voltage
20V
(adjustable)
40V
(adjustable)
50V
(adjustable)
100V
(adjustable)
100V
(adjustable)
Wind Turbine Charging Mode
MPPT and PWM
Solar Charging Mode
PWM
Control Dump-load Mode
Over rotate speed limiting, Over voltage limiting,Over current limiting ,PWM
Display Mode
LCD
Display Parameters
wind power , wind voltage , wind current , wind turbine rotate speed ,PV power ,
PV voltage , PV current , battery voltage , battery power ,charge current, over
voltage ,under voltage ,system state ,etc
Working Temperature
& Humidity
-20~+55°C/35~85%RH(Without Condensation)
Quiescent Power Drain
<3W
Protection Function
Solar reverse-charging protection , solar reverse-connection
battery over charge protection, battery over-discharge
battery reverse-connection protection,
wind turbine automatic brake, wind turbine manual brake
Communication (Optional)
RS232 or RS485
Storage (Optional )
USB data logging
Controller Size (L*W*H)
423 *450*175MM
Package Size (L*W*H)
510*545*250MM
Gross Weight
17KGS

4. Universal Function
4.1 Adaptive Impedance Matching of Wind Turbine & Load
Wind Turbine , battery and load all have internal resistance. According to impedance matching principle, only when
Input. impedance equals to output impedance, power utilization would be maximal , The energy utilization will be
improved to the utmost extent by adaptive impedance matching of controller .
4.2 Control mode of Wind Turbine Open Circuit & Dump-loading ; Over Rotate Speed Limiting, Over Voltage &
Over current Limiting
Traditional wind solar hybrid controller : When total current of wind & solar is higher than limiting current, battery
power increases . The excess energy will be dumped by PWM. Wind turbine rotate speed lower. And the excess energy
is consumed in mosfets or resistance . This leads wind turbine to heat , shortens wind turbine and controller’s working life.
This professional wind solar hybrid contoller :When total current of wind & solar is higher than limiting current, battery
power increases .PWM duty cycle of charging circuit is decreased until charging is finished .When charging finished.
Current circuit disconnected , wind turbine has no load ,In order to prevent wind turbine from a very quick rotate
speed , This professional controller provides the function of over rotate speed limiting and over voltage limiting,
Once the rotate speed or voltage exceeds what you set on the controller , The controller will start PWM smart
dump-loading automatically. Prevent wind turbine from working in unloading state for long time . This is good for
both wind turbine and controller .
4.3 Battery Maximum Charging Current Smart Limiting
Traditonal wind solar hybrid controller : Different wind solar hybrid systems need different capacity batteries;
Different capacity batteries have different maximum current, Traditional wind solar hybrid controller has no
settings for batteries maximum charging current , or have wrong settings , leads over current , shortens batteries
using life .
This professional wind solar hybrid controller : User can set the capacity of battery ,The professional
controller can calculate the maximum charging current intelligently according to user’s settings, Protect batteries .
4.4 Manual Brake
4.5 Using or not using wind turbine to charge battery could be set manually
User can choose whether use wind turbine to charge the battery ,Set wind “M-SW: ON”. Wind turbine charging is
normal .Set wind “M-SW: OFF”. Wind turbine charging is prohibited . Before connecting the wind turbine , User could
first set wind “M-SW: OFF”manually to prevent sparks .
4.6 Using or not using solar panel to charge battery could be set manually
User can choose whether use solar panel to charge the battery ,Set solar “M-SW: ON”, Solar panel charging is
normal . Set solar “M-SW: OFF”, Solar panel charging is prohibited. Before connecting the solar panels . User
could first set solar.
“M-SW : OFF ”manually to prevent sparks .
4.7 LCD display multi-level menu ; Intelligent button settings ;
The controller with LCD screen supports multi-level menu viewing. Users could set lots of parameters through
buttons.
The desigh of this controller is humanized .
7

5 .Optional Function
5.1 Optional Function 1 : Boost Function
Wind turbine output voltage intelligent boost
The boost module starts automatically when the wind turbine voltage is lower than battery voltage , ensure that the
wind turbine normally charges the battery. The boost module shuts off automatically when the wind turbine voltage is
higher than battery voltage.
Impedance matching self-adaption
Due to internal resistance of wind turbine, battery, load, According to the impedance matching principle, The wind
Turbine will have maximum power utilization rate and maximum power output only when the input impedance equals to
output impedance, with impedance matching self-adaption .This controller enhances energy efficiency.
5.2 Optional Function 2 : Buck Function
Wind turbine output voltage intelligent buck
The buck module starts automatically when the wind turbine voltage is higher than battery voltage , The controller
real-time tracks maximum power of wind turbine and real-time limits the current of wind turbine .To solve the
problem of overheating of wind turbine.
Wind Turbine Max Current Tracking (MCT) and Max Power Point Tracking (MPPT)
When wind is in the breeze , load will slow down wind turbine rotate speed, thus reducing wind turbine output power .
With MCT and MPPT ,Keep wind turbine output power on the maximum balance point of wind power utilization.
Combine with boost-buck circuit, improve the utilization coefficient of wind energy.
Impedance matching self-adaption
Due to internal resistance of wind turbine, battery, load, According to the impedance matching principle, The wind
Turbine will have maximum power utilization rate and maximum power output only when the input impedance equals to
Output impedance, with impedance matching self-adaption .This controller enhances energy efficiency.
5.3 Optional Function 3 : Boost & Buck Function
Wind turbine output voltage intelligent boost
The boost module starts automatically when the wind turbine voltage is lower than battery voltage , ensure that the
Wind turbine normally charges the battery. The boost module shuts off automatically when the wind turbine voltage is
higher than battery voltage.
Wind turbine output voltage intelligent buck
The buck module starts automatically when the wind turbine voltage is higher than battery voltage , The controller
real-time tracks maximum power of wind turbine and real-time limits the current of wind turbine .To solve the
problem of overheating of wind turbine.
Wind Max Current Tracking (MCT) and Max Power Point Tracking (MPPT)
When wind is in the breeze , load will slow down wind turbine rotate speed, thus reducing wind turbine output power .
With MCT and MPPT ,Keep wind turbine output power on the maximum balance point of wind power utilization.
Combine with boost-buck circuit, improve the utilization coefficient of wind energy .
Impedance matching self-adaption
Due to internal resistance of wind turbine, battery, load, According to the impedance matching principle, The wind
Turbine will have maximum power utilization rate and maximum power output only when the input impedance equals to
Output impedance, with impedance matching self-adaption .This controller enhances energy efficiency.
8

5.4 Optional Function 4 : RS Communication
RS232 or RS485 real time communication
With serial port communication . User can analyse the data from the software installed in the computer.
Procedure could be upgraded by RS232
Some customization functions could be altered through upgrad procedure by serial ports.
PC and controller both could set parameters
5.5 Optional Function 5 : USB data logging function
All data can be stocked into 8GB USB flash disk . User can check the system information with taking the USB flash disk out of
controller.
9

6. Design & Dimension
6.1 Design
10

6.2 Dimension
11

7 System Schematic
8 Installation
8.1 Warning
Pls read this chapter carefully before installation. To make sure the whole process is safe .
It is important to choose the installation location for controller. Keep the controller away from rain, insolation , put the
controller in dry ,ventilated place .
Metal material placed around the controller is prohibited, if not. may cause battery short circuit .
There should be enough space around the controller for cooling .
This controller could only charge to the lead-acid batteries which are in control range of this controller .
Not fully connection and corrosive wire will produce lot of heat .Then wire insulation layer may be melted, lead surrounding
material combustion ,even fire. So please ensure every connection is secure , to avoid connector loose when moving.
8.2 Installation Steps
Step 1 : Select Location Do not install the controller in place where insolate, high temperature and rainy. Pls keep enough
free air around the controller .
Step 2: Inspect Put the controller on the place where it is easy to install and inspect if there is enough space for
connections.
Step 3 : Mark Mark with 4 dots on install surface through controller’s 4 open holes.
Step 4 : Drill holes Drill 4 holes in the 4 dots which marked in setp 3 .
Step 5: Fix controller Aim controller’s 4 open holes towards the 4 holes which were drilled in step 4. Then fix controller
with screw nails .
Step 6 : Check Make sure the controller is firmly installed .
12
PC
Battery
Wind Turbine
Solar Panel

9 Electrical Connection
9.1 Terminal
9.2 Connection steps
Pls do the connections safely and strictly according to the steps below
Step 1 : Before connection . Pls put “ BATTERY” Switch to “ OFF” . Then , conect battery to
Controller’s “ Batttery ”Terminals with cuprum cable which more than 6mm²and less than 1 meter .
Although there is reverse connection protection ,But connecting battery reversely is forbidden !
Connection is finished ,Put “ BATTERY” Switch to “ ON”.
Step 2 : To prevent producing sparks while connecting, User are supposed to set wind, solar “M-SW: OFF .
Step 3 : Connect wind turbine to controller’s “Wind Input ”terminals ,Make sure positive to positive ,
negative to negative .
Step 4: Connect solar panels to controller’s “Solar Input ”terminals .Make sure positive to positive,
negative to negative .
Step 5 : After connecting ,User can do what he wants to do in step 2 to set Wind , Solar “M-SW : ON”.
Or you can do the operations on PC through RS232 .
10 Menu Operation
10.1 Buttons
Buttons
Description
It is used to select menu item and confirm parameter setting
It is used for left and right page turning in the screen or increase/ decrease number
It is used for left and right page turning in the screen or increase/ decrease number
It is used as return/finish function
13
Menu

10.2 Display on LCD Screen Default Interface
2 Solar voltage, Solar charging current
3 Wind turbine rotate speed .
Wind voltage, Wind charging current
4 Wind power , Wind output current
5 Total input power
Solar input power ,Wind input power
6 Total energy generated
14
Power on
1 **% Low
V: **V I:
**A
2 Solar :
V: **V I:**A
3 Wind : **R/min
V: **V I:**A
4 Wind -Power
P: **W I:**A
5 In -Power **W
S: **W W:**W
6 Total-Energy :
** W.h
1 Battery power:
* % stands for battery power range
Low : Battery low voltage , Normal :Battery normal voltage
Full : Battery full voltage , Float : Battery floating voltage
Ft **S : The countdown of exiting from floating charging
8 Erro Code
B0 : Battery normal , B1 : Battery discharged ,B2: Battery over-charged
S0 : Solar panel normal ,S1 : High PV input voltage , S2: PV charge fault
S3 : PV charge open circuit fault
W0 : Wind turbine normal , W1: manual brake on , W2: Battery fully charged
W3 : Maximum RPM protection , W4 :Vmax protection ,W5:Amax protection
W6: Brake module short-circuit fault
W7: Wind turbine charge module short-circuit fault
W8: Wind turbine charge module open-circuit fault
W9: Too high wind input voltage
T0 :Temperature normal ,T1: Mosfet temperature detection model fault
T2:Mosfet Over-Heating Protection,T6:Conteroller elements temperature detection
model fault T7 : Controller elements Over-Heating Protection
8 ErrCode :
B0 S0 W0 T0
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Main Menu
1 System Info
7 TP: Normal **C
TM: Normal **C
Menu
7 TP : Controller working temperature , Normal : Temperature normal
Error : Temperature detection model fault .OTP : Over-heating protection
TM :Mosfet working temperature, Normal : Temperature norm
Error : Temperature detection model fault .OTP :Over-heating protection

Addition 2 Decice -Address .
If you don’t buy the RS485 function , don’t have this menu
Addition 3 : Wind -Speed
If you don’t buy the wind speed detection function ,Don’t have this menu
10.3 Display on LCD Screen Main Menu Interface
Main Menu
1 System information
Main Menu
2 Wind Information
Main Menu
3 Solar Information
Main Menu
4 Date Time
If you don’t buy USB data logging
Function ,Don’t have this menu
15
A2. Decice-Addr:
A3. Wind-Speed:
***m/s
Addition 1 ****-**-** Year-Month-Day
USBOK :USB normal, USBNC : USB un-connected
USBdERR: USB module fault or un-connected
USBFULL : USB flash disk full
**-**-** : Hour- Minute-Second
If you don’t buy the USB data logging function ,Don’t have this menu
A1 ****-**-**
USB** **-**-**
Menu
Menu
Menu
1 **% Low
V: **V I: **A
Main Menu
1 .System Info
Main Menu
2 .Wind Info
Main Menu
3.Solar Info
Main Menu
4 .Date Time
Menu
Esc
Menu
Menu
Menu
Menu
Esc
Esc
Esc
10.4
10.5
10.6
10.7
Main Menu
1 SystemInfo

“ADD ”or “CLEAR”“flickers.
Press and to select “ADD” or “ CLEAR”. If
choose “CLEAR” and press “Menu”, Total-Energy
will be 0. Then it will be“ADD”again.
10.4 Display on LCD Screen System Information
16
Main Menu
1 .System Info
1 . System Info
Batt: **Ah 1/9
1 . System Info
Energy: ADD 2/9
1 . System Info
Low: ** V 3/9
1 . System Info
RLow: ** V 4/9
1 . System Info
Full: ** V 5/9
1 . System Info
RFull: ** V 6/9
1 . System Info
Flot: ** V 7/9
1 . System Info
Out: ** V 8/9
1 . System Info
Rout: ** V 9/9
Menu
Esc
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Battery capacity numeric flickers.
Press and to increase/decrease the
value. Press “Menu” , saved; Press “Esc” , not
saved.
Over-discharge voltage numeric flickers.
Press and to increase/decrease the
value. Press “Menu”,saved; Press “Esc” , not
saved.
Over-discharge recovery voltage numeric
flickers.Press and to increase/decrease the
value. Press “Menu” , saved; Press “Esc” , not saved.
Over-charge voltage numeric flickers. Press and
to increase/decrease the value. Press “Menu”
saved; Press “Esc” , not saved.
Over-charge recovery voltage numeric flickers.
Press and to increase/decrease the
value. Press “Menu” , saved; Press “Esc” , not
saved.
Floating voltage numeric flickers.
Press and to increase/decrease the
value. Press “Menu” , saved; Press “Esc” , not
saved.
This model doesn’t have this function.
This model doesn’t have this function.
Esc
Esc
Esc
Esc
Esc
Esc
Esc
Esc

“ON” or “OFF” flickers. Press and to
select “ON” or “OFF”. Press “Menu” ,saved;
Press “Esc” , not saved.
ON: Wind charging is on; OFF: Wind charging is off.
10.5 Display on LCD Screen Wind Information
17
Main Menu
2. Wind Info
2. Wind Info
MPPT : ON 1/9
2. Wind Info
Rota : **R 2/9
2. Wind Info
Pole : **D 3/9
2. Wind Info
Brake: OFF 4/9
2. Wind Info
M-SW: ON 5/9
2. Wind Info
Vmax : ** V 6/9
2. Wind Info
Amax: **A 7/9
2. Wind Info
Time :** min 8/9
2. Wind Info
CutIn: **V 9/9
Menu
Esc
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Wind turbine maximum limiting rotate speed numeric
flickers. Pres and to increase/decrease the
value .Press “Menu” , saved; Press “Esc” , not saved.
Wind turbine magnetic pole numeric flickers.
Press and to increase/decrease the
value. Press “Menu” , saved; Press “Esc” , not
saved.
“ON” or “OFF” flickers. Press and to
select “ON” or “OFF”. Press “Menu” , saved;
Press “Esc” , not saved.
ON: wind turbine brake is on;
OFF: wind turbine brake is off.
Wind turbine maximum voltage numeric flickers.
Press and to increase/decrease the
value. Press “Menu”, saved; Press “Esc”,not
saved.
Wind turbine maximum current numeric flickers.
Press and to increase/decrease the value.
Press “Menu” ,saved; Press “Esc” ,not saved.
Self-dumping time numeric flickers. Press and
to increase/decrease the value. Press “Menu”
saved; Press “Esc” , not saved.
Boost start voltage numeric flickers. Press and
to increase/decrease the value. Press “Menu” ,
saved; Press “Esc” , not saved.
Esc
Esc
Esc
Esc
Esc
Esc
Esc
Esc

“ON” or “OFF” flickers. Press and to select
“ON” or “OFF”. Press “Menu” , saved;
Press “Esc” , not saved.
ON: Solar charging is on;
OFF: Solar charging is off.
YEAR numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
MONTH numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
DAT numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
HOUR numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
MINUTE numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
SECOND numeric flickers. Press and to
increase/decrease the value. Press “Menu” , saved;
Press “Esc” , not saved.
10.6 Display on LCD Screen Solar Information
10.7 Display on LCD Screen Date Time
If you don’t buy USB data logging Function ,Don’t have this menu
18
Main Menu
3 .Solar Info
3 . Solar Info
M-SW : ON 1/1
Main Menu
4 .Date Time
4. ****-**-**
1-YEAR **-**-**
4. ****-**-**
2-MONTH **-**-**
4. ****-**-**
3- DAY **-**-**
4. ****-**-**
4- HOUR **-**-**
4. ****-**-**
5- MIN **-**-**
4. ****-**-**
6- SEC **-**-**
Menu
Esc
Esc
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Esc
Esc
Esc
Esc
Esc

11 PC Software Introduction
11.1 Software File :
Customer can use this software without installation. The RAR file includes ,database file, user files, detail file and etc. are
placed in the same directory.As the picture below:
11.2 Open the software:
Step 1 : Customer should connect the controller with battery or power supply to start the controller at first
Step 2 : Connect PC and the controller with serial cable . Click and open the RAR file and find the monitoring software.
Controller’s current state could be real-time monitoring. Step as follows:
19

11.3 Software Connection configuration :
Click “Setting” at first, click “Serial Port Setting” secondly, then serial port number and baud rate could be set. As below:
Remark : If workable port of the computer is COM 2 or COM 3 .customer should set the serial port as COM2 or COM 3.
Means customer should set the serial port as the real workable port according to their computer. Press OK after setting .
11.4 Parameters Settings:
Click “Setting”, and then click “Parameters Setting”, controller parameters could be set from your PC. Just like:
Press “Save ” after setting , Or customer can press “ One Key Recover” if he wants to reset to factory defaults
20
This manual suits for next models
13
Table of contents