FireProtect / FireProtect Plus User Manual
FireProtect (FireProtect Plus) is a wireless indoor inflammation detector furnished with a
buzzer. It can detect smoke generation and temperature increase and function up to 4 years
from a battery and can operate autonomously.
FireProtect (FireProtect Plus) operates within the Ajax security system, by connecting via the
protected Jeweller protocol to the hub. The communication range is up to 1,300 meters if there
are no obstacles. In addition, the detector can be used as part of third-party security central
units due to the Ajax uartBridge or Ajax ocBridge Plus integration module.
👉Buy fire detector with carbon monoxide sensor FireProtect Plus
The detector is set up via a mobile application for iOS and Android-based smartphones. The
user is notified of all events through push notifications, SMS messages and calls (if activated).
The Ajax security system is self-sustaining, but the user can connect it to the central monitoring
station of a private security company.
👉Buy fire detector FireProtect
Functional Elements

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
1. Siren hole
2. Light indicator combined with the touch button "Test"
3. Smoke chamber window, temperature detector behind the net
4. SmartBracket attachment panel
5. On/off button
6. Tamper button
7. QR code
FireProtect Operating Principle
FireProtect operates even without connecting to a security system, determining the smoke
contamination level of the room and temperature increase (In addition, FireProtect Plus
registers a dangerous CO level), including a sharp one - in the autonomous mode and
supplied from batteries.
If any fire (smoke) is detected, the detector will switch on a buzzer - the fire siren can be heard
from far, and the logo will light red. When connected to a security system, the detector will also
send an alarm signal to the hub - the user and private security company will receive the
respective notifications.
The detector detects smoke using an optical coupler consisting of an infrared emitter and
photoelectric receiver located in a smoke chamber. If smoke penetrates into the chamber, the
photoelectric receiver detects it based on the distortion of the infrared ray.
As some materials burn without smoke emission, the detector also records temperature
variation. When the function is enabled, the alarm will be actuated, if the room temperature rises
up to 60°С and if the temperature rises by 30° during 30 minutes (even if it is below 60°С).
Additionally, the FireProtectPlus detector model has a function to detect a dangerous CO
level in the room. If a certain concentration of CO in the air is exceeded, the detector
generates an alarm.
The detector activates:

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
within 60–90 min at carbon oxide concentration 50 ppm / 0.005%
within 10–40 min at CO concentration 100 ppm / 0.01%
within 3 min at carbon oxide concentration 300 ppm / 0.03%.
You can deactivate the siren in case of smoke/inflammation detection by pressing the touch-
sensitive button in the center of the detector's logo and via the Ajax Security System application.
If the smoke level and temperature do not return to normal, then FireProtect will activate the
siren again after 10 minutes.
Connecting the Detector to the Ajax Security System
Connecting to the hub
Before starting connection:
Following the hub instruction recommendations, install the Ajax application on your
smartphone. Create an account, add the hub to the application, and create at least one
room.
Go to the Ajax application.
Switch on the hub and check the internet connection (via Ethernet cable and/or GSM
network).
Ensure that the hub is disarmed and does not start updates by checking its status in the
mobile application.
⚠️Only users with administrative privileges can add the device to the hub.
How to connect the detector to the hub:
1. Select the Add Device option in the Ajax application.
2. Name the device, scan/write manually the QR Code (located on the body and packaging),
and select the location room.

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
For the detection and interfacing to occur, the detector should be located within the coverage
area of the wireless network of the hub (at a single protected object). Request for connection to
the hub is transmitted for a short time at the time of switching on the device.
If the connection to the Ajax hub failed, sensor will work autonomously; switch off the detector
for 5 seconds and repeat the attempt.
The detector connected to the hub will appear in the list of devices of the hub in the application.
Update of the detector statuses in the list depends on the device inquiry time set in the hub
settings, with the default value - 36 seconds.
Connecting the Detector to Third Party Security Systems
To connect the detector to a third party security central unit using the Ajax uartBridge or Ajax
ocBridge Plus integration module, follow the recommendations in the manual of the respective
device.
The smoke detector always operates in the active mode. When connecting FireProtect to third-
party security systems, it is appropriate to place it in a permanently active protection zone.
States
Devices → FireiProtect

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
Parameter
State
Smoke detected
Smoke alarm state
Temperature threshold exceeded
The alarm state for exceeding the threshold
temperature
Rapid temperature rise
The alarm state for rapid temperature rising
Temperature
Temperature of the device. Measured on the
processor and changes gradually
Signal Strength
Signal strength between the hub and the
detector
Battery Charge
Battery level of the device
Backup Battery Charge
Backup battery level of the device
Lid
The tamper mode of the device, which reacts to
the detachment

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
Connection
Connection status between the hub and the
device
Smoke detector
State of the smoke detector
Smoke detector dust level
Dust level of smoke chamber
Firmware
Detector firmware version
Device ID
Device identifier
Setting Up the Detector
Devices → FireProtect → ⚙️
Setting
Value
First field
Device name, can be edited

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
Room
Selecting the virtual room to which the device is
assigned
High temperature alarm
If active, detector will react if temperature is 60°C
and higher
Rapid temperature rise alarm
If active, detector will react on rapid temperature
rising (30°С for 30 minutes or less)
Alert with a siren if smoke detected
If active, HomeSiren and StreetSiren are activated in
case of smoke alarm
Alert with a siren if temperature threshold
exceeded
If active, HomeSiren and StreetSiren are activated in
case if temperature threshold exceeded
Alert with a siren if rapid temperature rise
detected
If active, HomeSiren and StreetSiren are activated in
case if rapid temperature rise detected
Signal Strength Test
Switches the device to the signal strength test mode
FireProtect self-test
Starts FireProtect self-test
User Guide
Opens the detector User Guide
Unpair Device
Disconnects the sensor from the hub and deletes its
settings
Indication
Event
Indication
Detector switch on
LED lights up green for 1 second
Detector switch off
The logo blinks red three times and the device
switches off
Registration failed
The logo blinks greed for a minute, then the
device switches over to the autonomous mode
Detector detected smoke contamination and
temperature increase
The siren switches on, the logo lights red until
the end of the fire/smoke detection
Battery low
One short sound signal per 90 sec - main
batteries low (CR2)
Two short sound signals per 90 sec -
backup battery low (CR2032)
Three short sound signals per 90 sec - all
the batteries low
Performance testing

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
The Ajax security system allows conducting tests for checking the functionality of connected
devices.
The tests do not start straight away but within a period of 36 seconds when using the standard
settings. The test time start depends on the settings of the detector scanning period (the
paragraph on “Jeweller” settings in hub settings).
Signal Strength Test
Attenuation Test
FireProtect Self Test
Pursuant to the requirements of the standard EN50131, the level of the radio signal sent by
wireless devices is decreased during the test mode.
Detector Testing
Prior to installing FireProtect, check the smoke detector. To test, switch on the device and press
the touch-sensitive button in the logo center for 10 seconds - the detector will test the smoke
chamber with the electronic simulation of smoke generation and then will switch on the siren for
8 seconds.
You will receive the corresponding notification in the application regarding the test result and
detector status.
Installing of the device
Selection of the Detector Location
The performance efficiency of the detector depends on its location.
Location of FireProtect as a security system element determines its remoteness from the hub
and presence of any obstacles between the devices, hindering the radio signal and sound
transmission: walls, inserted floors, large-size objects located within the room.
Check the signal level at the installation location
If the signal level is one division, we cannot guarantee stable operation of the security system.
Take possible measures to improve the quality of the signal! As a minimum, move the device -
even 20 cm shift can significantly improve the quality of reception.
If, after moving, the device still has a low or unstable signal strength, use a radio signal range
extender ReX.
The detector should be installed at the ceiling in the highest point where hot air and smoke are
concentrated.
If there are any beams at the ceiling, protruding by 30 or more centimeters from the ceiling
level, then the detector should be installed between every two beams.
Detector installation process
Before installing the detector, make sure that you have selected the optimal location and it is in
compliance with the guidelines contained in this manual!

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
1. Fix the SmartBracket panel on the ceiling using bundled screws. After selecting other
attachment hardware, make sure that they do not damage or deform the panel.
The double-sided adhesive tape may be only used for temporary attachment of the detector.
The tape will run dry in course of time, which may result in the falling and damage of the
detector.
2. Put the detector on the panel - the detector will blink with the logo, confirming the tamper
switching. Turn the detector clockwise to fix it on SmartBracket.
If the LED in the detector logo is not actuated after installation, check the status of the
tamper in the Ajax Security System application and then the fixing tightness of the device on
the panel.
In case of opening the SmartBracket panel (removing the detector from the ceiling), you will
receive the notification.
Do not install the detector:
outside the premises (outdoors)
in places with fast air circulation (near a ceiling fan, air conditioner, air exhaust, open doors
and windows)
nearer than a meter from the vertical projection of the cooking surface
nearby any metal objects or mirrors causing attenuation and screening of the signal
in a room with the humidity exceeding
Autonomous Use of the Detector
The FireProtect detector can be used autonomously, without connecting to a security system.
1. Switch on the detector by pressing the on/off button for 3 seconds (the logo will light up
green for 1 second) and conduct testing.
2. Determine the optimal location of the detector following the recommendations in the second
part of the section "Selection of the Detector Location" of this manual.
3. Install the FireProtect detector as described in the section "Installation of the Detector".

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
In case of the autonomous use, the detector will notify of the detected fire/smoke with a sound
signal and light of the logo. To switch off the siren sound, press on the logo (there is a touch-
sensitive button under it) or eliminate the cause of the actuated alarm.
Detector Maintenance and Battery Replacement
Check the operational capability of the FireProtect detector on a regular basis.
Clean the detector body from dust, spider web and other contaminations as they appear with a
soft dry napkin suitable for equipment maintenance.
Do not use for cleaning any substances containing alcohol, acetone, gasoline and other active
solvents.
Any dust that penetrated into the smoke chamber is perceived by the detector as smoke. The
dust content of the chamber is compensated up to some level, and then cleaning will be
required - the detector will send the respective notification. The detector also signals about the
contaminated smoke chamber or a failure using a long sound signal once every minute and a
half.
How to clean up the smoke chamber
Batteries installed in the detector ensure up to 4 years of autonomous operation. If the batteries
are discharged, the security system will send the respective notifications and the detector will
activate a sound signal once every 90 seconds.
if the main batteries are low - a single short signal;
if the backup battery is low - two short signals;
if all the batteries are low - three short signals.
Battery Replacement
Tech Specs
Smoke-sensitive element
Photoelectric sensor
Temperature sensitive element
Thermocouple
Sound notification volume
85 dB at a distance of 3 m
Alarm threshold at the
temperature
60°С
Tamper protection
Yes
Frequency band
868.0 –868.6 MHz or 868.7 –869.2 MHz depending on the region of
sale
Maximum RF output power
Up to 20 mW

TH COMMUNICATION SDN BHD www.thcomm.com.my info@thcomm.com.my
Radio signal modulation
GFSK
Radio signal range
Up to 1,300 m (any obstacles absent)
Power supply
2 x CR2 (main batteries), CR2032 (backup battery), 3 V
Battery life
Up to 4 years
Operating temperature range
From 0°С to +65°С
Operating humidity
Up to 80%
Overall dimensions
132 х 132 x 31 mm
Weight
216 g
Complete Set
1. FireProtect / FireProtect Plus
2. Batteries CR2 (pre-installed) - 2 pcs
3. Battery CR2032 (pre-installed) - 1 pcs
4. Installation kit
5. Quick Start Guide
Warranty
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY
products is valid for 2 years after the purchase and does not apply to the pre-installed battery.
If the device does not work correctly, you should first contact the support service —in half of the
cases, technical issues can be solved remotely!
This manual suits for next models
1
Table of contents
Other TH COMMUNICATIONS Security Sensor manuals
Popular Security Sensor manuals by other brands

Varian
Varian 956 Installation, operation and maintenance instructions

Siemens
Siemens FPT-11 installation instructions

FixPosition
FixPosition Vision-RTK 2 Integration manual

PCB Piezotronics
PCB Piezotronics ICP 356A32 Installation and operating manual

Orno
Orno OR-MA-705: OR-MA-710 Operating and instalation instructions

Securam
Securam SH-DW01 Operation instructions