Therapure TPP250 User manual

by
TP250050710
air purifier with uv light
by
TPP250 TPP250
air purifier with uv light
®
owner’s guide

SAFETY INSTRUCTIONS 2
IMPORTANT WARNINGS 3
UV Lamp Notice 3
Mercury Notice 3
UV Lamp Disposal Notice 3
UV Lamp Breakage 3
PRODUCT BENEFITS 4
MAIN PARTS 5
OPERATING THE THERAPURE®250 AIR PURIFIER 6
Getting Ready 6
Controls/Settings 7
Operation 7
CLEANING & MAINTENANCE 9
Cleaning the Permanent Filter 9
Maintenance UV Lamp 10
Cleaning External Surfaces 10
Replacing the UV Lamp 11
TROUBLE-SHOOTING 12
ONE-YEAR LIMITED WARRANTY 13
Thank you for purchasing the Therapure®
250 air purifier. With UV germicidal
protection to kill germs and permanent
HEPA type filtration to purify the air, the
Therapure®250 air purifier will greatly
improve the quality of the air in your
home, office or other environments.
We want you to be fully satisfied with
your Therapure®250. That’s why your
Therapure®250 comes with a one-year
limited warranty.
Once you’ve experienced the purity of
Therapure®air, visit us at our website
to find out more ways to improve the
quality of your air and your life with our
premium products and upgrades.
Please be sure to read the following
instructions carefully to ensure optimal
performance and safety.
www.envionproducts.com
Table of conTenTs
by

2 3
250
safeTy insTrucTions imPorTanT warnings
SAVE THESE INSTRUCTIONS
WARNING: RISK OF ELECTRICAL SHOCK
Safety precautions should always be used when operating this or any electrical appliance.
Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the
warnings below.
Use only as described in this Therapure®manual. To reduce the risk of electric shock, do
not attempt to service the product in any way other than in the manner described in the
“Cleaning & Maintenance” section of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER.
»This product operates at 120V AC, 60Hz only.
»Do not run power cord under carpets, and do not cover with throw rugs.
»Do not operate the product in any greasy environment, such as in the kitchen. This product is
not intended to filter oil or grease from the air.
»Do not use the Therapure®250 air purifier in bathrooms or other humid environments. Do not
use near fireplaces or in areas where flammable or combustible vapors or products may exist.
»Always unplug the power cord from the electrical outlet when the purifier is not in use, before
cleaning, inserting or removing parts or before moving to another location.
»Never run the air purifier unless it is fully assembled.
»To reduce the risk of electric shock, this product has a polarized plug (one blade is wider than
the other). This plug will fit into a polarized outlet only one way. If the plug does not fit into the
outlet, contact qualified service personnel to install the proper outlet. Do not alter the plug in
any way.
»Always turn off all controls before unplugging the Therapure®250 air purifier from the outlet.
»Attempting to service the Therapure®250 air purifier in any way that is not described in this
owner’s manual will cause the warranty to be voided and could cause serious personal injury
to the user and/or result in considerable damage to the unit.
»Do not place the cord near a heated surface.
»Never operate the Therapure®250 if the plug or cord is damaged or appears damaged. Only
qualified service personnel should replace or attempt to replace a damaged power cord.
»Never use the power cord to pick up, carry, drag, pull, or lift the Therapure®250 air purifier.
Do not pull the cord against or around sharp corners and edges. This could result in injury to
the user or damage to the cord.
»Always remove the plug from its power outlet by holding onto the plug itself and pulling gently.
»Never pull on the cord itself to unplug it from its power outlet.
»Use care when operating the Therapure®250 air purifier by keeping all foreign objects, fingers,
body parts, hair, loose clothing and jewelry away from openings.
»Never touch the Therapure®250 air purifier or its plug when your hands are wet.
»The Therapure®250 air purifier is an electrical appliance. Adult supervision is required when
operating the Therapure®250 in the presence of children.
»To reduce the risk of fire or electric shock, do not use this air purifier with any solid-state speed
control devices.
UV Lamp Notice
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.
Never look directly at the UV lamp while it is illuminated; doing so could cause loss of vision!
Only view illumination through the window at the front of the unit. To prevent exposure to
ultraviolet light, disconnect the power to the unit before servicing any part of the Therapure®250
air purifier.
Mercury Notice
This device contains mercury in the sealed ultraviolet lamp(s). Do not place your used lamp(s) in the
trash. Disposal of any item containing mercury must be in accordance with any hazardous waste
disposal or recycling laws and regulations of your state.
UV Lamp Disposal
If the UV lamp breaks, turn off the unit. Do not operate the unit with a broken lamp. Do not use a
vacuum to clean up breakage. Sweep debris into a plastic bag and dispose of properly. Contact your
local waste management authority for instructions regarding recycling and the proper disposal of
old lamp(s). To order a replacement lamp, call 1.800.875.8577 or go to www.envionproducts.com.

4 5
250
ProducT benefiTs
»Quadruple action purification:
1. Permanent HEPA type Filter takes particles
out of the air, purifying it.
2. UV lamp kills germs, such as
viruses and bacteria.
3. Photo catalyst filter removes VOCs
(volatile organic compounds) from the air,
including toxic fumes and chemicals, such
as paint and new carpet fumes.
4. Ionizer refreshes the air.
»24 hr. Timer to set runtime.
»Effectively removes smoke, pollen, dust,
animal dander, dust mites, mold and bacteria.
»3 speed fan setting–lets you select the
desired cleaning level.
main ParTs
1. Locking Latch
2. Air Inlet Grill
3. Permanent HEPA Type Filter: the permanent filter removes small visible and non-visible
particles down to 0.1 microns in size.
4. UV Lamp Cover
5. Control Panel
6. LCD Display
7. Power Button
8. ION Button
9. UV/VOC Button: the germicidal UV light is used to kill harmful airborne bacteria,
germs and viruses and reduce harmful VOC (volatile organic compounds).
10. Speed Button: there are 3 speed settings: (low, medium and high) for you to
choose from according to the air quality needs in the room.
11. Timer Button
12. Air Outlet Grill
13. Base of Unit

6 7
250
oPeraTing The TheraPure®250
Before using the Therapure®250 air purifier, please read the following important information.
Electrical Ratings:
120V Setting: 120Vac, 60 Hz
Power consumption: 60 watts at high fan speed,
4 watt UV light bulb
Net weight: 11.25 lbs.
Dimension (LxWxH): 11.2” x 9.8” x 28.15”
Replacement Parts:
Lamp – TPP 2500
Filter – TPP250F
Locate a level surface on which to place
the Therapure®250 air purifier near a 120V
outlet (follow warnings in the “SAFETY
INSTRUCTIONS” and “IMPORTANT
WARNINGS” sections of this manual).
Position your Therapure®at least one foot
(12 inches) from the wall. Plug in the unit.
oPeraTing The TheraPure®250
Controls/Settings
Power Control – To operate the Therapure®250 air purifier,press the “ON/OFF” button to turn
on the air purifier, press the button again to turn off the air purifier.
Timer Control – The Therapure®250 air purifier can be programed to turn off after a preset amount
of time. Press the “TIMER” button to program the timer. Each press will add one hour up to a total
of 24 hours. If you keep the button pressed, the timer will increase to 24 hours, after that it will turn
back to off.
ION Control – Press the ION Control button to turn on the ions. Press it again to turn off the ions.
Speed Control – The Therapure®250 has three different speeds of cleaning, LOW, MED and HI.
Press “SPEED” button to cycle the settings and select the fan speed you desire. The speed state
will be shown on the LCD display.
UV Control – Press the UV/VOC control button “UV/VOC” to turn on the UV lamp to kill harmful
airborne germs and reduce harmful VOC (volatile organic compounds). Press it again to turn off the
UV and VOC.
LCD Display
ION Button
Timer Button
Speed Button
Power Button
UV/VOC Button

8 9
250
oPeraTing The TheraPure®250
Safety
1. Do not place near fans.
2. Keep both sides of the unit at least 1 foot away from a wall.
3 Do not place the unit near curtains.
4. Placing the unit close to the source of air pollution is an effective way to improve
indoor air quality.
Note:
DO NOT run the Therapure®250 with a broken filter. Replace the filter if the filter has a tear
or a hole in it.
If the filter is damage or needs replacement, please visit our web site at www.envionproducts.com
to order for a replacement filter. Or call 1.800.875.8577.
cleaning & mainTenance
Keep the Therapure®250 functioning properly by cleaning the Permanent HEPA type Filter. More
frequent cleaning will be necessary if the unit is located in an area with a high level of airborne
contaminants (excessive amounts of smoke, pet dander, etc.).
Exposing the Therapure®250 to candle/oil/fireplace soot and smoke is not recommended and will
require more frequent cleaning.
Cleaning the Permanent HEPA type Filter
Note: Always make sure the Therapure®250 is turned off and unplugged before cleaning.
1. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).
2. Remove the inlet grill from the unit as shown below.
3. Grasp the left and right frames of the Permanent HEPA type Filter through the indentations on
the sides of the filter enclosure and remove the filter.
4. To clean the Permanent HEPA type Filter, use the brush or crevice attachment with your vacuum
cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the
crevices as much as possible. Do not use water or any household cleaners or detergents to
clean the Permanent HEPA type Filter.
1. 2.
4.3.
1. 2.
3. 4.

10 11
250
cleaning & mainTenance
NOTE:
»Vacuuming will restore performance of the Permanent HEPA type Filter. However,
the filter may appear stained. This is normal and does not affect performance in any way.
»Do not use water or any household cleaners or detergents to clean the Permanent
HEPA type Filter.
»We recommend that under normal conditions of continuous use, the filters be cleaned
every month to maintain optimal functioning.
»The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum
or a slightly damp cloth.
Cleaning External Surfaces
1. Turn off and unplug unit.
2. Use a washcloth slightly dampened with a little water and dishwashing soap
to wipe the outer case surfaces.
3. Do not allow water to slip into the internal parts as this could damage your unit
and result in electrical shock and injury to you.
4. Allow the unit to thoroughly dry before use.
UV Lamp
The lifetime of the UV lamp is up to 18 months of continuous, effective operation. After this time,
the bulb may remain illuminated, but its effectiveness is greatly reduced. For maximum germicidal
protection, please replace the UV bulb annually.
If the lamp stops functioning or needs replacement, please visit our web site at:
www.envionproducts.com to order a replacement lamp. Or call 1.800.875.8577.
Caution:
* Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness
of the lamp.
* Never operate the unit without a filter or with a damaged filter. UV lamp cover must be
installed at all time. The UV light from the UV lamp will result in severe damage to eyes and
could cause blindness.
UV Lamp Notice Warning:
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.
Never look directly at the UV lamp while it is illuminated–doing so could cause loss of vision!
Before replacing the UV lamp, make sure the Therapure®air purifier is turned
off and unplugged.
Replacing the UV Lamp:
1. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).
2. Remove the two bolts which used to fix the UV lamp cover and take the cover out from the unit.
3. Unscrew the old UV lamp from the lamp base of the unit.
4. Install the new UV lamp into the lamp base of the unit.
5. Install the UV lamp cover with the two bolts on the unit.
6. Install the inlet grill on the unit.
cleaning & mainTenance
1. 2.
3. 4.
5. 6.

12 13
250
one-year limiTed warranTy
ONE YEAR LIMITED WARRANT Y
Your Therapure®250 air purifier is warranted to be free from defects in materials and workmanship
for one year from the original purchase date, excluding the lamp. Should the product have a defect
in materials or workmanship, we will repair or replace it without charge to you (a shipping and
processing fee may apply). To obtain service under warranty, simply call our Customer Service
Center toll-free at 1.800.875.8577.
This warranty does not cover any damage caused by accident, misuse or any use other than as
intended and described in this owner’s guide, or damage resulting from failure to maintain and clean
this product as specified in this owner’s guide. This warranty applies only to the original purchaser of
the Therapure®250 air purifier.
Contact Info for Warranty Service:
Therapure®by Envion LLC
P.O. Box 9159 |Van Nuys, CA | 91409-8291
1.800-875-8577 | www.envionproducts.com
©2010 Envion, LLC. All Rights Reserved.
Patents pending.
TroubleshooTing
PROBLEM REASON SOLUTION
Unit will not operate.
Reduced airflow or
poor filtering.
No visible light in the
UV light view window.
Power button has not been
turned on.
Unit is unplugged.
The inlet grill has not been
installed & locked into place.
The inlet or outlet grill may
be blocked.
Permanent filter may
be clogged.
UV button is not turned on.
UV lamp is broken.
Press the Power button
Check to ensure unit
is plugged in.
Check to make sure filter
is properly installed & locked
into place.
Check to ensure nothing is
blocking air inlet & air outlet.
Check & clean filter,
if necessary.
Check that the UV button
is turned on.
Replace the UV lamp.
The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between
the model’s CADR for dust and the electrical energy it consumes, or CADR/Watt.
by
Table of contents
Other Therapure Air Cleaner manuals

Therapure
Therapure TPP50 MINI User manual

Therapure
Therapure 100 User manual

Therapure
Therapure 1040808 User manual

Therapure
Therapure 201M User manual

Therapure
Therapure TPP201M User manual

Therapure
Therapure TPP640S User manual

Therapure
Therapure TPP540 User manual

Therapure
Therapure TPP100 User manual

Therapure
Therapure TPP640S User manual

Therapure
Therapure TPP640S User manual
Popular Air Cleaner manuals by other brands

Whirlpool
Whirlpool Whispure Whispure Air Purifier Use & care guide

Coway
Coway AP-1516D user manual

Hunter
Hunter PermaLife 37750 owner's manual

Fellowes
Fellowes AeraMax SE manual

Temspec
Temspec Air Medic TIF-06 Installation, operation & maintenance manual

Jet
Jet AFS-1000C Operating instructions and parts manual