THERMOFAN TF2100 User manual

PLEASE ENSURE YOU HAVE READ
AND FULLY UNDERSTOOD THIS
GUIDE BEFORE INSTALLATION!
BATHROOM FAN HEATERS

WWW.
Please ensure you have thoroughly read and understood these instructions and the safety
notes before commencing installation.
Retain this leaflet for future reference.
Before operating remove the packaging and check product integrity. In the case of defects or damages
contact your dealer.
The TF2100 Fan Heater is designed to provide an instant heat source for bathrooms, kitchens and small
rooms.
The safety and installation instructions must be followed accurately. Failure to do so will void the
product warranty.


WWW.
The TF2100 Bathroom Fan Heater is designed to be mounted on the wall in the vertical position.
The TF2100 has an IP rating of IP21 which means it can be used in bathrooms and areas subject to
humidity as long as it is not installed within the perimeter of baths and showers. The Heater can be
installed in Zones 2 and 3.
We recommend that the TF2100 Bathroom Heater is installed a minimum of 50cm from the roof and
180cm from the floor and 15cm from walls and other objects.
Loosen the two screws at the top, front of the Fan Heaters and remove front cover. Drill two 8mm
diameter holes in the wall 190mm apart where you want
the top of the unit to be positioned. Drill another 8mm
diameter hole 115mm below in the center of the two top
holes. Insert the three plastic wall plugs supplied with the
unit, then screw two screws provided into the lower
holes. Leave these screws protruding by 3mm.
Hang the heater on these screws, ensuring a snug fit by
tightening and loosening screws as necessary. Use the
wall bracket to secure the heater by fitting the last screw
into the upper hole.
Remove the fixing board from inside the heater. Thread
the supply cable through the hole in the rear of the case.
Then make connections to the supply terminals according
to the colour code [Blue: Neutral, Brown: Live] ensuring
no strands or whiskers are protruding from the terminals.
Secure the cable under the fixing board, taking care not to over tighten the screws.
Select the desired mode of operation using the switch. i.e. I= 1kW fixed heat, II= 1kW fixed heat + 1 kW
variable thermostat controlled, set the thermostat to the mid position.
Close and secure the front cover and restore the power switch on.
min
15
cm
min
cm
15
min
60
cm
min
cm
50
0
min
15
cm
4 mm
Ø:6mm / L:35mm
220
mm
190mm
115mm
Ø: 8mm

Switch off the main power, then safely remove the two screws on the front of the case and remove
the front cover.
Select the desired mode of operation using the switch. i.e. I= 1kW fixed heat, II= 1kW fixed heat + 1
kW variable thermostat controlled.
Turn the thermostat control clockwise to increase the room temperature and anti-clockwise to
decrease.
Close the front cover and secure using the screws. Switch on the power supply.
This model has two levels of over-heat protection.
This product is fitted with a thermal cut-out which, in the event that it malfunctions or overheats,
the thermal cut-out switches the heater off automatically. When this happens, the heater will reset
itself once the temperature has reduced sufficiently.
This Thermal fuse is added as an additional safety feature. This is a non-resettable switch which will
require the unit to be returned to the supplier for a replacement.
The most common cause of over-heating is deposits of dust or fluff entering the heater. Ensure
theses deposits are removed regularly by electrically isolating the unit and vacuum clean the air
vents and front grille.

WWW.
The in-built cut out on this appliance is a safety device which switches the heater off, if the
operating temperature gets too hot.
The thermal fuse is an additional safety feature to cut out the power to the unit should it overheat.
The pull cord on the appliance operates the ON/OFF Switch (an indicator light Illuminates when the
appliance is on).
The heater has an internal thermostat which should be set during installation, the thermostat has 3
different settings:
1= Low 2= Med 3= High
This gives you an approximate temperature range of between 0OC and 85OC.
The electric heater should be cleaned regularly.
Disconnect electricity supply and allow heater to cool, wipe the surface clean with a soft damp
cloth. Do NOT use detergents or abrasives.
IMPORTANT: Any cut off plug should be disposed of safely to prevent a hazard. There is a danger of
electric shock if a cut off plug is inserted into a socket outlet.
2000W; 240V; ~50Hz
0oC –85oC
W237 x H244.5 x D130mm

Thermogroup covers all its products with a satisfaction guarantee. In addition,
Thermogroup will supply a replacement product where a fault is shown to be caused by
manufacture, materials or workmanship providing the goods have been installed correctly
and according to installation instructions. This guarantee does not include removal, freight
or installation costs. Thermogroup’s products come with guarantees that cannot be
excluded under Australian Consumer Law and you are entitled to a replacement or refund
for a major failure & compensation for any other reasonable foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure.
The TF2100 Fan Heater has a 2-year warranty. To use the warranty, repair or service the
customer must provide purchase invoice/receipt, and any other relevant details.
If the product develops a fault within the warranty period due to normal wear and tear,
Thermogroup at its discretion will recognise whether it’s a faulty product or not. If it is
impossible or not economical for the manufacturer to repair the product, the manufacturer
will replace the faulty product with a new unit of the same model or if there is no stock
available of the same model as the product, the manufacturer will replace the product with
a new unit of a similar size. No responsibility can be taken for altered dimensions and lining
up of existing holes.
The repair service offered within the warranty period only covers the faults and problem as
developed from the manufacturer’s errors. Any damage caused by improper use or
carelessness or incorrect wiring is not covered.
Thermogroup is not responsible for any monetary loss or injuries caused by improper use
of this product.
Table of contents