AIR-COOLED SCROLL-TYPE CHILLER
8
III. Unit Description
1. Scope of Application, Purposes and Characteristics
Air-cooled scroll-type chiller uses the innovative modular design. The entire unit is composed
of one or more modules, each of which consists of three or four independent cooling systems.
The electric controllers of modules are independent of each other and modules are
connected through communication cables to form a control network.
Air-cooled scroll-type chillers can be widely applied in new and restructured Industrial and
civil construction projects, such as hotels, shopping malls, office buildings, entertainment
centers, theaters, stadiums, plants, hospitals, high-grade apartments, and industrial cooling
sites. Air-cooled scroll-type chillers do not need dedicated equipment rooms and cooling
towers, and therefore, they become the optimal choice for Central Business Districts (CBDs)
and water-stressed regions.
The unit has the following features:
High efficiency, energy saving, and reliable performance
The unit uses efficient scroll compressors and world famous excellent cooling parts, to ensure
the maximum energy efficiency of the unit. The modular combination design allows the unit to
automatically lower the load in the case of partial loading, thereby achieving energy-efficient
operation.
High-precision EXVs for throttling
The unit uses Electronic Expansion Valves (EXVs) as fine and adaptive control components for
refrigerants, to implement dynamic matching between the refrigerant and compressor for the
coolingsystem. This fully improves the optimum efficiencyof every component in the system and
ensures the best operation pressure and temperature for the system.
Support for connection to the building automation system
The unit is equipped with RS485 interfaces for connecting to the centralized building control
system. It can be integrated into the centralized building control system via legitimate
protocols, to implement building automation.
Convenient installation
The compact air-cooled scroll-type modular machine can be placed on roofs, spacious
balconies, and other appropriate open spaces, which saves installation space. In addition,
cooling towers, cooling water pumps, boilers, and relevant pipes are not required, making the
installation of the entire central air conditioner easier.
Intelligent defrosting
The unit automatically determines the optimal defrosting time based on the ambient
temperature and actual operation parameters, to prevent frost residue or frequent defrosting.
In addition, intelligent defrosting can prevent air conditioning effect from being affected by
large water supply temperature fluctuation during unit defrosting. But heat pump type units