TIME MARK 36 User manual

⚫ 12 individual outputs
⚫ 3 Output Options
⚫ Sequence or Random Modes
⚫ Random or Adjustable Time On/Off
⚫ Remote Start (2 wire or 3 wire)
⚫ Engineered and Built in the U.S.A.
DIMENSIONS
MODEL 36
Splash Pad Controller
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
SPECIFICATIONS
Model 36
Input voltage 24VAC +/-10%
Power consumption 12W
Signal input (trigger) 2 wire / 3 wire
Display type 7 segment LED / 17 LED’s
Output 12 relays (SPST)
Output configuration See output setup
Surge protection 1500W (10/1000 µs)
Circuit breaker 500mA*
Operating temp. 0 – 130°F
Humidity 0 – 90% non-condensing
Dimensions 12.0”x 5.5”x1.88”
Weight 2.5 lbs.
Country of Origin U.S.A.
12.00"
5.50"
1.88"
1.36"
11.50"
5.00"
10.13"
DESCRIPTION
The Time Mark Model 36 Splash Pad Controller can
sequence up to 12 channels with one to four channels
active at a time. The controller offers 2 modes of
operation:
Sequence Mode: Once triggered, the unit will activate
up to four outputs for a predetermined time, deactivate
those outputs and then repeat with the next outputs in
sequence.
Random Mode: Once triggered, the unit will activate up
to four outputs for a random amount of time (120 to 300
sec.). After that, the unit will deactivate those outputs
(1 to 30 sec.), then pick a new set of outputs.
In either mode: you can adjust the total run time, the
number of outputs (up to four), the length of time they
stay on and the length of time before the next group of
outputs come on.
Custom programming is available from the factory.
* Circuit breaker protects Model 36 only

MODEL 36 12 Channel Splash Pad Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 36.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation and Setup Instructions
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
POWER AND TRIGGER CONFIGURATIONS
1) Connect the Model 36 to 24VAC (L1, L2) and earth ground as shown below
2) The Model 36 requires a two or three wire external trigger (switch) to operate. See wiring diagrams.

OUTPUT SETUP
Select one of 3 output relay options before final
mounting:
1) No jumper — The relay is a dry contact (SPST/N.O.)
for that channel.
2) Jumper center and upper pin — The relay will
provide 24VAC to the output pin for that channel.
3) Jumper center and lower pin — The relay will provide
ground to the output pin for that channel.
MODEL 36 12 Channel Splash Pad Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
RELAY
OUTPUT
PIN
HEADER
SWITCH
L1
SWITCH
L2
DRY
CONTACT
1J8
JUMPER
UPPER
TWO
PINS
JUMPER
LOWER
TWO
PINS
DO NOT
INSTALL
JUMPER
2J9
3J10
4J11
5J12
6J13
7J14
8J15
9J16
10 J17
11 J18
12 J19

Control functions (cont.)
(6) Output enable/disable – 12 position dip switch
(Channels set to OFF are disabled)
(7) Time adjustment control
Output ON time: 120 – 300 Sec.
Output OFF time: 1 – 30 Sec.
Run time: 5 – 30 Min.
(8) Output indication (12 LED’s)
LED’s indicate when a channel is ON
Press the Power button.
Press and hold the select switch until the OUTPUT ON
LED blinks. Adjust the Time Adjust pot until the desired
time is shown on the display.
Press the select button again and the OUTPUT OFF
LED will blink. Adjust the Time Adjust pot until the
desired time is shown on the display.
Press the select button again and the RUN TIME LED
will blink. Adjust the Time Adjust pot until the desired
time is shown on the display.
All settings are stored in non-volatile memory.
MODEL 36 12 Channel Splash Pad Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE
(1) Power switch – turns controller on and off.
(2) LED Indicators:
POWER – Indicates unit is on.
OUTPUT ON – Indicates when outputs are on
OUTPUT OFF – Indicates when outputs are off
RUN TIME – Indicates the total cycle time between
external triggers.
ERROR – Indicates an error in setup
LED’s will blink if potentiometer is set to
minimum, maximum or if the number of outputs
to activate (switches 3 & 4) is greater than the
number enabled (switch S1).
Note: The number of outputs enabled should
be two times the number to be activated.
(3) Seven segment display
During set up, the display will show the ON time,
OFF time or CYCLE time.
During normal run, the display will count down the
ON or OFF, or show PLA (“PLA” indicates the
controller is waiting for a trigger).
(4) Function select switch
Used to pick the parameter to adjust (setup) or to
scroll through the settings (normal)
(5) Control functions (4 position dip switch)
Position 1
Position 2
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
MODEL 36 CONTROL FUNCTIONS
BASIC SETUP
Position 3 Position 4 Number of outputs
OFF OFF 1
ON OFF 2
OFF ON 3
ON ON 4
ON Output in sequence
OFF Output is random
ON Random time ON up to value set by pot
OFF Exact time set by pot
TIME ADJUST
120 - 300 SEC.
2 3 4 5 6 7 8 91 10 11 12
OUTPUTS
1 2 3 4 1
OFF OFF
12
FUNCTIONS OUTPUTS ENABLE
Switch 3
OFF
ON
OFF
ON
Switch 4
OFF
OFF
ON
ON
OUTPUTS
1
2
3
4
FUNCTIONS:
TIME MARK
www.time-mark.com
12 CHANNEL RANDOMIZER / SEQUENCER
MODEL 35
ENGINEERED AND BUILT IN THE U.S.A.
SELECT
POWER
OUTPUT ON
OUTPUT OFF
RUN TIME
POWER
ERROR
Switch 1 - ON
output
in sequence
OFF
output
is random
Switch 2 - Random on time
up to value set
Exact on time
set by pot
by pot
1
234567
8

MODEL 36 12 Channel Splash Pad Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
SAMPLE CONFIGURATION
Example:
Splash pad with 9 features connected to outputs 1-7, 10
and 11, turning on a random 3 outputs at a time for 3
minutes followed by an off time of 3 seconds between
feature changes.
“Outputs Enable” switches are as set as follows:
Switches Down (ON): 1-7, 10 and 11
Switches Up (OFF): 8, 9 and 12
“Functions” switches are set as follows:
Switches Down (ON): 4
Switches Up (OFF): 1-3
WARRANTY
This product is warranted to be free from defects in
materials and workmanship for one year. Should
this device fail to operate, we will repair it for one
year from the date of manufacture. For complete
warranty details, see the Terms and Conditions of
Sales page in the front section of the Time Mark
catalog or contact Time Mark at 1-800-862-2875.

Have Questions? Call us at (800) 862-2875.
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://time-mark.com 03/2021
© 2021 TIME MARK CORPORATION
11440 East Pi n e S t r e e t
Tulsa, Oklahoma 74116
Table of contents
Other TIME MARK Controllers manuals
Popular Controllers manuals by other brands

Alphawave Photonics
Alphawave Photonics AWCL-300-6P-Audio user manual

Sel
Sel SEL-2241 quick start guide

IMG STAGE LINE
IMG STAGE LINE CU-4SMART instruction manual

MH Corbin
MH Corbin CONNECT:ITS Series User & installation manual

Delta
Delta VFD-E user manual

Contro l4
Contro l4 C4-HC1000-E-B Technical specifications