DESCRIPTION
Time Mark’s handheld Phase Sequence Detector can
help you quickly and easily verify the wiring on your
3-phase applications. Connect the Detector to any
3-phase circuit with nominal operating voltage from
188 to 660 volts (Wye or Delta with operating
frequencies of 50, 60, or 400 Hz) and LED’s will indicate
phase sequence (ABC or CBA), phases present or
missing and 400Hz frequency. A Low Battery lamp is
also provided to indicate when the 9V battery needs to
be replaced. Time Mark’s Phase Sequence Detector is
engineered and built in the U.S.A. and has a 5-year
warranty.
Package contents include:
(1) Phase Sequence Detector with insulated and color-
coded test leads
(1) Protective silicone boot
(1) 9V Battery
(1) Instruction Sheet
CONDITION LAMP(S) LIT
CHART ABC CBA ABC
ABC ROTATION ••••
CBA ROTATION ••••
PHASE A MISSING ••
FLASH
PHASE B MISSING ••
PHASE C MISSING ••
>2 PHASES MISSING OFF
SPECIFICATIONS
MODEL 188
Monitoring Voltage 188-660 VAC
Frequency 50-60Hz/400 Hz
Configuration Wye or Delta
Power Source 9V battery (included)
Power Down Timer 1.5 minutes
LED Indicators Phases (A, B, C), Rotation (ABC, CBA),
400 Hz. Frequency, Low Battery
Leads 18” Insulated & color-coded
Phases: A (red), B (black), C (white)
Lead Termination Alligator clips
Weight 9.1 oz.
Dimensions 4.77” x 3.09” x 1.17”
Enclosure Material ABS plastic
Country of Origin U.S.A.
⚫ Tests Phase Orientation on 3-Phase Power
⚫ Indicates Missing Phase
⚫ Indicates Phase Sequence ABC or CBA
⚫ Indicators for Low Battery and 400Hz
⚫ Color-coded and Insulated Leads
⚫ 5 Year Warranty
⚫ Engineered and Built in the U.S.A.
MODEL 188
Phase Sequence
Detector
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://time-mark.com 09/2020
© 2020 TIME MARK CORPORATION
11440 Eas t Pi n e S t r ee t
Tulsa, Oklahoma 74116
CONNECTION
1) Press the “ON” button
Both ABC and CBA lamps will flash. If the “LOW BATT”
lamp flashes or the rotation lamps do not flash then
replace the battery with a fresh 9V battery.
2) Remove power from the 3-phase power source then
connect the three clip leads.
3) Apply AC power and verify connections.
In proper phase sequence, and with all phases present,
the ABC lamp, and the three line voltage lamps will
illuminate. If the detector indicates all three phases
present, but the CBA lamp is illuminated, disconnect
power and change any two of the three leads. If there is
a loss of one or more phases, both ABC and CBA lamps
will flash. Refer to condition chart on page 1 for more
details. Check for loss of one or more phases and
correct.
4) Remove power and connect corresponding leads to
your equipment after correcting all issues and verify
that the sequence detector indicates all three phases
are present and in the proper ABC sequence.
BATTERY REPLACEMENT
1) Disconnect test leads from power source.
2) Remove the silicone boot on the detector and turn
unit face down in palm or on a clean flat surface.
3) Gently press in at the top of the battery compartment
(located near the bottom of the back side of the unit)
and slide the compartment door towards the bottom of
the unit.
4) Replace old 9V battery with a new 9V battery,
observing polarity.
5) Replace battery compartment door and silicone boot.
WARRANTY
This product is warranted to be free from defects in
materials and workmanship, and is covered by our
exclusive 5-year Unconditional Warranty. Should this
device fail to operate for any reason, we will repair it for
five years from the date of manufacture. For complete
warranty details, see the Terms and Conditions of Sales
page in the front section of the Time Mark catalog or
contact Time Mark at 1-800-862-2875.
MODEL 188 Phase Sequence Detector
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 188. ALL
ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING. THIS DEVICE
SHOULD BE OPERATED BY QUALIFIED PERSONNEL.
OPERATOR INSTRUCTIONS
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://time-mark.com 09/2020
© 2020 TIME MARK CORPORATION
11440 Eas t Pi n e S t r ee t
Tulsa, Oklahoma 74116
DIMENSIONS
18" LEADS
4.77"
3.09" 1.17"
TYPICAL APPLICATION
MOTOR
A
B
C
A B C

Popular Security Sensor manuals by other brands

Intermatic EK4000 Series Installation and setup instructions

Intermatic

Intermatic EK4000 Series Installation and setup instructions

JXCT JXBS-3001-SCY-PT2 manual

JXCT

JXCT JXBS-3001-SCY-PT2 manual

GE Baker Hughes Reuter-Stokes Flame Tracker... Operation and maintenance manual

GE

GE Baker Hughes Reuter-Stokes Flame Tracker... Operation and maintenance manual

B.E.G. LUXOMAT LC-Click 140 Installation and operation instruction

B.E.G.

B.E.G. LUXOMAT LC-Click 140 Installation and operation instruction

Visonic TOWER 20 AM - INSTALLER GUIDE installation instructions

Visonic

Visonic TOWER 20 AM - INSTALLER GUIDE installation instructions

jablotron JA-81M quick guide

jablotron

jablotron JA-81M quick guide

EDS ES Series installation manual

EDS

EDS ES Series installation manual

Olympus EPOCH 6LT User Interface Guide

Olympus

Olympus EPOCH 6LT User Interface Guide

PCB Piezotronics 117B13 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 117B13 Installation and operating manual

Bentel Security AMC10 quick start guide

Bentel Security

Bentel Security AMC10 quick start guide

GST C-9105R Installation and operating manual

GST

GST C-9105R Installation and operating manual

Schambeck RI 2012 Operation manual

Schambeck

Schambeck RI 2012 Operation manual

Pepperl+Fuchs GLP30-RT/40b/103/123/143 manual

Pepperl+Fuchs

Pepperl+Fuchs GLP30-RT/40b/103/123/143 manual

MSA V-TEC Tie-Back PFL User instructions

MSA

MSA V-TEC Tie-Back PFL User instructions

nedis DTCTCS10WT instruction manual

nedis

nedis DTCTCS10WT instruction manual

Dors 1300 user manual

Dors

Dors 1300 user manual

DAINESE D-AIR STREET SMART CHEST Series INFORMATIVE NOTE

DAINESE

DAINESE D-AIR STREET SMART CHEST Series INFORMATIVE NOTE

Crow SWAN 1000 installation instructions

Crow

Crow SWAN 1000 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.