manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rielta
  6. •
  7. Security Sensor
  8. •
  9. Rielta ORLAN-2 User manual

Rielta ORLAN-2 User manual

SECURITY COMBINED PIR +
GLASS BREAK DETECTOR
«ORLAN-2»
Installation Guide
1 General Information
Security combined PIR + glass break ceiling-mounting detector
«Orlan-2» (hereinafter, the Detector) has the following two independent
detection channels:
- Glass break channel (hereinafter, GB channel);
- Passive infrared channel (hereinafter, PIR channel).
GB channel is intended for detecting destruction of plate glass.
PIR channel is assigned for detecting intrusaion into protected area
of closed premises.
The Detector generates an alarm message by output relay contacts
opening.
2 Features
Table 1
Parameter Value
PIR channel detection zone diameter at
mounting height of 5 m, not less
9 m
Minimum controlled glass area, not less 0,1 m2
0,05 m2
PIR channel detected speed range 0,3...3 m/s
Power supply, V DC 9...15 V
Maximal current, commutated by executive
relay contacts at maximal voltage 72 V
30 mА
Warm-up time after energizing, not more 60 s
Operating temperature
From minus 20 to
+45 °С
PIR channel detection angle in horisontal
plane
360°
GB detection angle:
- horisontal
- vertical
1200
900
IP rating IP30
Relative humidity without moisture conden-
sation
95% at 25 °С
Current consumption, maximum 35 mА
Dimensions (diameter х height), not more 105 х 48 mm
Weight, not more 100 g
Average service life 8 years
3 Choosing the Installation Place
When choosing the Detector installation place, it is advisable to
take note of the fact that the detection zone may be limited by non-
transparent objects (curtains, houseplants, cabinets, bookcases, etc.),
as well as by glass and mesh partitions. There must be no windows, air
conditioners, space heaters or heating radiators in the PIR detection
zone. Maximal installation height is 5 m. Distance between the Detector
and the farthest point of the monitored glass should not exceed 6
m. The Detector microphone should be oriented strictly towards the
protected surface of a glass construction. The Detector wires should
be laid far enough from power supply cables.
PIR channel detection zone pattern is shown in Figure 1.
Figure 1 – PIR channel detection zone pattern
Figure 2 – GB channel detection zone pattern
Side view
Microphone orientationMicrophone orientation
Top view
R 6 м
90 0
R 6 м
120 0
100 г
105 х 48 мм
95% при 25 °С
от минус 20 до плюс 45 °С
объемная конусообразная.
10 дальних зон, 1 средняя,
1 ближняя
9 м
35 мА
6 м
0,1 м2
3 м
3600
1200
900
0,05 м2
· put off the printed circuit board (PCB) by unfastening the latch,
located on the base;
· Drill the holes in the base (See Figure 3) for the Detector wiring
and fastening the base;
· Choose the place of installation, mark the places for mounting
holes with regard to the openings on the detector base, drill holes in
the place of installation;
· Pass the wire through the mounting holes in the base, leaving
several centimeters of installation wire for its fastening to the socket
inside the case;
· Fix the base of the detector on the chosen place
· set down PCB and microphone on their places.
4 Installation of the Detector
· Put off the Detector cover by its turning counter-clockwise until
tight (See Figure 3);
Figure 3 – Base and cover of the Detector
Base Cover
Holes for wiring
Slot
Latch
Holes for a base
fastening
Microphone mounting
seat
10 m
5 m
9 m
5 Connection
Fulfill connections in accordance with Figure 4.
Figure 4 – The Detector connection pattern
To CP «Alarm»
via GB channel
+12V- FAILURE GB Loop PIR Loop
To CP «Alarm»
via PIR channel
To control panel (CP)
«Tamper or failure
message»
To power
supply unit
- Set operation mode by means of DIP-switches in accordance with
particular application conditions (DIP-switches assignment is listed in
the Table 2);
- Install the Detector cover on its place.
Table 2
DIP-switch Position
Mode
DIP-switch
ON OFF
GB sensitivity «1» max - 6 dB
GB sensitivity «2» max -12 dB
Installation height «3» 5 m 2,5 m
Alarm memory «4» ON OFF
Indication «5» ON OFF
Test mode «6» ON
OFF
(standby mode)
6 Functional Check
1. PIR Channel Check
For the installation at 5 m height set DIP-switch «3» to position
«ON» (See Table 2). If the height of the premises ceiling is less than
3 meters, it is recommended to set DIP-switch «3» to «OFF» position,
ensuring increase of the interference-immunity level. It is recommended
to use this mode of the Detector operation for small premises with
high-interference environment.
Energize the detector and wait for 1.5 – 2 minutes. Begin moving
across the detection zone with the speed 0.5 – 1 m/s. The detector
must generate alarm message, therewith the red LED indicator switches
ON and PIR loop contacts open. Wait until the LED indicator goes
out and start moving across the detection zone other way around.
The detector must generate alarm message. Under the absence of
movement inside the detection zone, alarm message should not be
generated.
2. GB Channel Check
Set DIP-switches «1», «2» to position «OFF» and «6» to position «ON»
(minimal sensitivity level, testing mode). Put the cover on its place.
Suspend a steel ball 21-22 mm in diameter on a 35 cm long thread
near the farthest part of the monitored glass (ordinary, ornamental,
armed, laminated), deflect it at an angle of 30-70° (see Table 3, for
hollow glass blocks - 45°) . Deliver a test blow to the remote section
of the protected glass.
Table 3
Glass thickness, mm <3 3...4 4...5
5...6
6...7 >7
Ball deflection angle
for ordinary, armed and
ornamental glass, °
30 35 40 45* 50 55
Ball deflection angle for
hardened and laminated
glass, °
45 50 55 60 65 70
*– Inclination angle for glass blocks.
During delivering a blow an operator himself should not occlude the
Detector. If the test blow results in activation of an «Alarm» signal, the
Detector is considered to be adjusted. If the test blows give no result,
adjust the Detector sensitivity by means of DIP-switches «1» and «2»
(Listed in Table 2). Thereupon repeat GB channel check.
It is permitted to use an electronic glass break simulator.
After adjustment procedure finishing, set DIP-switch «6» in «OFF»
position (standby mode) and close the cover.
«Test» mode goes out in 15 minutes.
To reset the channel check mode, turn the DIP-switch «6» ON and
OFF.
7 Informativity
The LED indication displays the state of the Detector (See Table 4)
Table 4
LED Indication
Mode
LED Indicator
(number of pulses in
series)
Relay
Green Red GB
Loop
PIR
Loop FAILURE
Technical readi-
ness
- GB
- PIR
OFF OFF
(1)
+
+
-
Norm OFF OFF - - -
GB Alarm OFF ON + - -
PIR Alarm OFF ON - + -
Tamper OFF OFF - - +
Failure:
- Usupply < 9 V;
- t° > 51 °C
(1)
(2) OFF + + +
Alarm memory ON OFF - - -
GB channel inter-
ferences:
Low frequency
High frequency
1 Hz
10 Hz
OFF
- - -
«+» – Relay contacts opened
(1) – Unitary flashes
(2) – Double flashes
8 Alarm Message Storage
Set DIP-switch «4» in «ON» position. In this mode within 5 minutes
after generation of GB Alarm or PIR Alarm messages, the green
LED indicator is lighting during 15 min.
9 Indicator Disabling
For the Detector operation masking, possibility of indication disabling
is available. Set DIP-switch г5” in гOFF” position. There is no visible
Alarm LED indication in this mode.
10 Scope of Delivery
10.1 Each Detector unit package contains the items listed in Table 1.
Table 1
Name Qnt
Security combined PIR + glass break ceiling-mounting
detector «Orlan-2»
Screw1-3 х 20.016
Security combined PIR + glass break ceiling monting
detector «Orlan-2». Installation Guide
1 шт.
2 шт.
1 экз.
11 Manufacturer’s Guarantees
11.1 The manufacturer guarantees conformity of the Detector to its
Technical Specifications if provided that the transportation, storage,
installation and operation conditions are observed.
11.2 The guaranteed shelf life of the Detector is 63 months since
the date of manufacture.
11.3 The guaranteed useful life is 60 months since the day of putting
into operation within the guaranteed shelf life.
11.4 The Detectors that are found non-conforming to the Technical
Specifications shall be repaired by the manufacturer, provided the
installation and operation rules have been complied with.
12 Storage and Transportation
12.1 The Detectors in their original packaging may be transported
by any means of transportation in closed vehicles over any distances in
compliance with the existing shipping rules concerning the respective
means of transportation.
12.2 The storage premises should not contain any current-conduc-
ting dust, acid and alkali fumes, or corrosive or destroying insulation
gases.
12.3 The Detectors in transport packaging should be stored no lon-
ger, than 3 months. Otherwise they should be released from transport
packaging.
13 Acceptance and Packing Certificate
13.1 Security combined PIR + glass break ceiling-mounting detector
«Orlan-2»,
batch number________________________,
has been manufactured in compliance with the active technical
documentation, classified as fit for operation and packed by «RIELTA»
JSC.
Person in charge of acceptance and packing
QC representative _______________ ___________________
(month, year)
«RIELTA» JSC, www.rielta.ru
Chapaeva Str. 17, Saint Petersburg Russian Federation 197101, [email protected]
Tel./fax: +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]
Rev.1 of 20.05.14
№
И00062
Made in Russia

Other Rielta Security Sensor manuals

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Rielta Ladoga IPR-RK User manual

Rielta

Rielta Ladoga IPR-RK User manual

Rielta FOTON-16A User manual

Rielta

Rielta FOTON-16A User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta OCHRANA Ladoga MK-RK User manual

Rielta

Rielta OCHRANA Ladoga MK-RK User manual

Rielta STEKLO-3RK User manual

Rielta

Rielta STEKLO-3RK User manual

Rielta FOTON-SH2-RK User manual

Rielta

Rielta FOTON-SH2-RK User manual

Rielta FOTON-10MD User manual

Rielta

Rielta FOTON-10MD User manual

Rielta FOTON-SH1 User manual

Rielta

Rielta FOTON-SH1 User manual

Rielta FOTON-17 User manual

Rielta

Rielta FOTON-17 User manual

Rielta chrana ORLAN-SH User manual

Rielta

Rielta chrana ORLAN-SH User manual

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Rielta PYRONE-8-RK User manual

Rielta

Rielta PYRONE-8-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta FOTON-15A User manual

Rielta

Rielta FOTON-15A User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta PYRONE-5 User manual

Rielta

Rielta PYRONE-5 User manual

Rielta IPDL-Ex User manual

Rielta

Rielta IPDL-Ex User manual

Rielta FOTON-10B User manual

Rielta

Rielta FOTON-10B User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta C.Nord CN-PIR User manual

Rielta

Rielta C.Nord CN-PIR User manual

Rielta C.Nord CN-Flood-Mini User manual

Rielta

Rielta C.Nord CN-Flood-Mini User manual

Rielta PYRONE-4i User manual

Rielta

Rielta PYRONE-4i User manual

Popular Security Sensor manuals by other brands

MSA FlameGard 5 quick start guide

MSA

MSA FlameGard 5 quick start guide

Bosch RF940U installation instructions

Bosch

Bosch RF940U installation instructions

ABLE Ultima OPIR-5 Installation & maintenance instructions

ABLE

ABLE Ultima OPIR-5 Installation & maintenance instructions

Hilti PS 35 operating instructions

Hilti

Hilti PS 35 operating instructions

Extronic Electronic PD-33 DL installation instructions

Extronic Electronic

Extronic Electronic PD-33 DL installation instructions

REED R5044 instruction manual

REED

REED R5044 instruction manual

Kingspan SafePro 2 Installer's guide

Kingspan

Kingspan SafePro 2 Installer's guide

IQ-group E-700 Installer's guide

IQ-group

IQ-group E-700 Installer's guide

Servodan niko 41-720 user manual

Servodan

Servodan niko 41-720 user manual

ESYLUX PD-C360i/24 DIMplus manual

ESYLUX

ESYLUX PD-C360i/24 DIMplus manual

Elektor TAPIR Construction manual

Elektor

Elektor TAPIR Construction manual

ST Quadrat LUX-top GBD-RR 465 installation instructions

ST Quadrat

ST Quadrat LUX-top GBD-RR 465 installation instructions

MAXIMUM Security Multi Zone manual

MAXIMUM Security

MAXIMUM Security Multi Zone manual

UTC Fire and Security Det-Tronics Dual Spectrum PM-5MPX instructions

UTC Fire and Security

UTC Fire and Security Det-Tronics Dual Spectrum PM-5MPX instructions

Honeywell Home SIXCOMBO-CN Quick installation guide

Honeywell Home

Honeywell Home SIXCOMBO-CN Quick installation guide

EDS SCL-01 technical information

EDS

EDS SCL-01 technical information

EMX Industries RAVEN instruction manual

EMX Industries

EMX Industries RAVEN instruction manual

steute sWave 2.4 GHz-safe Mounting and wiring instructions

steute

steute sWave 2.4 GHz-safe Mounting and wiring instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.