TLA The Pro Series User manual

The Pro Series
The PRO Series utilizes digital controls and 5W high output LED’s to provide red and near-
infrared light.
With the use of 60 degree secondary glass lenses, a high output irradiance is created for
optimal light therapy at a touch.

Introduction
Intelligent digital controls, mean you can enjoy 3 models in one!
•Red
•NIR
•Or Both, to provide the most optimal spectrums for light therapy simultaneously.
Our Pro range includes a daisy chain set up kit.
The daisy chain function means you can connect multiple panels according your
requirements, and link them all from one digital control panel.
The Digital display and timing system, means you can enjoy light therapy according your
time requirements, without needing an alarm. Just set the timer for 1-20minutes and the
machine will turn off once the session is completed. These features and more make this
range ideal for professional users. Here is a quick guide to get started!
PRO TIPS
BEFORE WE GET STARTED, PLEASE READ THESE TIPS!
There are two switches on your device. Only switch on the Big orange/red button unless you
are using more then one panel at once via daisy chain. (more on this later)
Please keep eyes closed, or wear provided goggles while using this product.
We repeat do not stare directly into the light!
Get Naked! for best results, you want nothing between your skin and the light.
BE CONSISTANT, DON’T OVERUSE! Consistent small sessions are what this therapy is all
about!
Please do not rush, start small and build up. In most cases, you will want to build up to 2-14
sessions per week, with 20 mins per session maximum session time and ONE SESSION PER 6
HOUR PERIOD MAXIUM.
For aches and pains you should try a close distance, maybe 10cm for 2-4 mins twice a day.
For skin conditions, try exposing the affected area at a distance of 30cm for 10 mins twice /
day.
Don’t exceed 20 mins total usage in any given 6 hour period.

Getting Started
You can mount your light however you chose to! Just be careful and make sure it is secure and can’t
easily fall over!
We supply a door mount and adjustable pulley system with your light! More on that soon.
Below you can see a few examples of how you may set up your device.
For larger areas, simply connect more panels!

How To Hang?
(for daisy chain connection, see the next page)
Step 1: Screw the threaded
posts into the top of your
light. Next Screw the Cable
supports to the top of the
threaded posts.
Step 2: Attach the Universal
Door Hook to the door.
Step 3: Connect the
Adjustable Pulley Kit to the
lights Cable support, and the
door mount.
Step 4: To adjust the height
of the light SUPPORT THE
BOTTOM of the light with
one hand, while pulling
down on the adjustment
cable. To release, use the
release button. Always
support the light while
adjusting.

Daisy chain
Step 1: Attach the lead unit to a door. Also Prepare the secondary unit by screwing in the threaded
pole mounts into the top of the unit.
Step 2: Line the secondary unit up with the lead unit, and push the threaded poles up into the holes
in the primary unit. Push the secondary unit back to lock into place.
Step 3: Follow the Diagram to attach the chords so that the daisy chain function works seamlessly.
Plug the digital (Aux cable looking) chord into both devices. (NOTE it does not matter which aux
inputs you use, each machine has 2)
Step 4: Connect the power linking cable from the primary unit to the secondary unit. Then plug the
secondary unit into the wall. Note ONLY ONE UNIT NEEDS TO BE PLUGGED INTO THE WALL.
Once all is connected switch all power switches on. You will only need to use one digital control
panel to control all devices.

Cooling Down
After sessions, your machine/s fans will automatically continue to run to ensure all LED’s are cooled
completely. It is recommended that you always let the machine cool down in this way before turning
off the main power switch.


Care
To preserve the life and functionality of the device, always store in a cool, dry place
when possible. For proper use and safety, please be sure to read this manual and follow
all instructions and do not do any of the following with the device:
•DO NOT let children use the device Without adult supervision.
•DO NOT use this device on infants.
•DO NOT let sleeping, disabled (unable to move away from or operate the light), or
unconscious persons use the device.
•DO NOT exceed 20 minutes of use in one therapy session.
•DO NOT use on open, fresh wounds.
•DO NOT use in combination with liniments, salves,ointments, or balms that contain heat
producing ingredients. A skin burn could be the result of doing so.
•DO NOT modify or attempt to repair This equipment. There are no parts that are
serviceable by the user.
The TLA light is an electrical device. To avoid electric shock and other electricity-related
dangers, adhere to the following instructions:
•DO NOT wash electrical parts with water or other liquids.
•DO NOT drop your device in water or other liquids or place it where it may fall into
water or other liquids. Do not expose to running water. If your device comes into contact
or becomes submerged into water or other liquid, unplug it immediately from the
electrical power outlet. If device is to be used in the vicinity of water, we recommend
using an electrical outlet protected by Ground Fault Circuit Interrupter.
•DO NOT directly touch the device or touch the plugs or switches with wet hands.
•DO NOT apply or touch the device to, or with, wet or damp skin.
•DO NOT pull, carry, or lift the device by its cord. If the cord is damaged, don’t use the
device.
•DO NOT use on or near heated surfaces.
•DO NOT operate this device in areas Where it could be exposed to flammable or
combustible products or vapours. Explosion of fire may occur.
•DO NOT store your device in hot temperatures exceeding 140 degrees fahrenheit.
•DO NOT use your device if it is damaged. Continuous use of a damaged device may result
in electric shock or injury
•DO NOT use extension cords unless they are designed to carry the total wattage of the
device being powered.
•DO NOT unplug by pulling directly on the cord. Grasp the plug itself, not the cord, when
unplugging from an outlet.
•DO NOT cover the cooling fans while Operating the device Cautions TLA recommends
consulting with your healthcare provider prior to use if you believe that you are
sensitive to light. Some cold and allergy medications, pain medications, and medications
used to treat infection may cause light sensitivity. We also recommend consulting with
your healthcare provider prior to using the device if you are pregnant, have any
suspicious or cancerous lesions, or have recently had a steroid injection or use topical
steroids. If you experience discomfort or have a concern about the device, stop use
immediately and contact your healthcare provider. Unplug from outlet when not in use
to avoid tripping hazards.
Disposal directions; found on the device or within its packaging, indicates that this
device may not be disposed of with other household waste. This device requires

disposal via a designated collection point for the recycling of electrical waste. Please
recycle your equipment at the time of disposal to help conserve natural resources and
protect human health and the environment. We accept old models for free and will
organise recycling for you, just send it to us!