Toa N-8000 SERIES User manual

OPERATING INSTRUCTIONS
N-8000 SIP GATEWAY
Thank you for purchasing TOA’s N-8000 SIP Gateway.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
Rev. 1.00

2
TABLE OF CONTENTS
Chapter 1 General Description
1. GENERAL DESCRIPTION ...................................................................... 1-2
2. SYSTEM IMAGE ............................................................................................ 1-2
3. BASIC FUNCTIONS .................................................................................... 1-2
4. SETTING STRUCTURE ............................................................................ 1-3
Chapter 2 Functions
1. CONDITIONS OF SIP GATEWAY ....................................................... 2-2
2. SIP GATEWAY STRUCTURE ................................................................ 2-2
3. SIP GATEWAY FUNCTIONS .................................................................. 2-3
3.1. Details of functions ............................................................................................ 2-3
3.1.1. Audio conversion ................................................................................. 2-3
3.1.2. Call from N-8000 to SIP ..................................................................... 2-4
3.1.3. Call from SIP to N-8000 ..................................................................... 2-5
3.1.4. Paging function ................................................................................... 2-6
3.1.5. Control functions ................................................................................ 2-6
Chapter 3 Settings
1. SETTINGS .......................................................................................................... 3-2
1.1. Setting image for N-8000 side and SIP telephone side,
and a main of SIP Gateway ......................................................................... 3-2
1.2. Setting of N-8000 system ............................................................................ 3-2
1.3. Preparation for and ................................................................................. 3-3
1.4. Preparation for SIP Client setting ..................................................................... 3-3
1.5. SIP Client Setting ......................................................................................... 3-4
1.6. SIP Gateway Setting .................................................................................... 3-5
1.7. Setting example of N-8000 SIP Gateway ......................................................... 3-6
Chapter 4 Setting of SIP server
1. SETTING OF SIP SERVER ..................................................................... 4-2
1.1. Setting for Asterisk ............................................................................................ 4-2
1.2. Setting for FreeSwitch ...................................................................................... 4-3
1.3. Setting of Cisco Call Manager .......................................................................... 4-5
1.3.1. Registration procedure of SIP Client into Cisco SIP Server ................... 4-5

Chapter 1
General Description

Chapter 1
General Description
Operating Instructions 1-2
1. GENERAL DESCRIPTION
This manual is described for N-8000 SIP Gateway that has interconnecting functions between N-8000 and
SIP system.
2. SYSTEM IMAGE
3. BASIC FUNCTIONS
N-8000 SIP Gateway has new functions by software working on Windows7 Professional 32/64bits, as below.
Function of N-8000 SIP Gateway Description
Interconnection between SIP and N-8000
functions: , , , , and
This software converts a call from N-8000 to SIP
system and vice versa. One software has 5 speech
paths at the same time. Transferring functions are
also available from N-8000 to SIP system.
Paging from SIP to N-8000.
functions:
This software brings a “zone paging” and an “All-
call paging” to the system. SIP telephone can make
any paging. One server has 5 paging channels at
the same time.
Contact control from SIP telephone
functions:
Dialing by a SIP telephone can control contact
output of N-8640/50DS.
Note
-indicates functions’ name which are explained in Section2.

Chapter 1
General Description
Operating Instructions 1-3
4. SETTING STRUCTURE
There are 2 software settings to create a system, and another setting is needed for the other system which is
SIP system.
Note
- indicates settings which are explained in Section3 and 4.

Functions
Chapter 2

Chapter 2
Functions
Operating Instructions 2-2
1. CONDITIONS OF SIP GATEWAY
N-8000 SIP Gateway is tested with a SIP server of Cisco Systems, Asterisk, FreeSwitch, and Sipelia of
Genetec Security Center.
2. SIP GATEWAY STRUCTURE
A SIP Gateway consists of 5 virtual master stations with one virtual N-8000EX, 5 virtual SIP clients, and audio
processing functions.
There are 5 channels of speech paths between SIP telephone and N-8000. SIP Gateway has an audio
processing function.
Virtual N-8000EX
Virtual N-8000MS 1
Virtual N-8000MS 2
Virtual N-8000MS 3
Virtual N-8000MS 4
Virtual N-8000MS 5
Virtual SIP Client 1
Virtual SIP Client 2
Virtual SIP Client 3
Virtual SIP Client 4
Virtual SIP Client 5
+Protocol Converter between SIP
and N-8000Next
+Audio converter

Chapter 2
Functions
Operating Instructions 2-3
3. SIP GATEWAY FUNCTIONS
There is a function of converting from SIP protocol to N-8000 and vice versa.
There are 5 speech paths between SIP telephone system and N-8000.
SIP Gateway converts from SIP audio to N-8000 audio, and vice versa.
N-8000 station is connected to SIP telephone via N-8000 virtual station in a SIP Gateway.
SIP telephone is connected to N-8000 station via virtual SIP Client station in a SIP Gateway.
SIP telephone makes a station paging to N-8000 system with additional dials.
SIP telephone makes contact output control of N-8640/50DS as known “Door Remote Control” function.
3.1. Details of functions
Functions of and are skipped.
3.1.1. Audio conversion
A SIP Gateway converts audio from N-8000 to SIP telephone and vice versa.
Both sides have a different sampling frequency and audio codec.
•N-8000 16kHz,8kHz/G.722
•SIPsystem 8kHz/G.711u-law

Chapter 2
Functions
Operating Instructions 2-4
3.1.2. Call from N-8000 to SIP
By an example, its function is explained below.
[System example]
[Setting concept]
When N-8000 calls 801, virtual SIP client 1 has a setting to call to 2001.
Automatically transfer to 2001.
When N-8000MS(102) calls 805, virtual SIP client 5 has a setting to call to 2005,
within a selected time (0 to 5 seconds), N-8600MS dials 2004, then talk.
[Operation]
Tip
This "additional dial" function is only for N-8600MS with a special rmware. (The rmware is in a CD.)

Chapter 2
Functions
Operating Instructions 2-5
3.1.3. Call from SIP to N-8000
By an example, its function is explained below.
[System example]
[Setting concept]
When SIP telephone calls 3995, virtual N-8000MS 1 has a setting of calling 101.
SIP telephone and N-8000 101 starts to talk.
When SIP telephone calls 3999, virtual N-8000MS 5 has a setting of calling 202,
Within a selected time (0 to 5 seconds), SIP telephone dials 103, then talk.
[Operation]

Chapter 2
Functions
Operating Instructions 2-6
3.1.4. Paging function
Paging from SIP telephone to N-8000 system.
3.1.5. Control functions
Door remote control from SIP telephone for Door stations.

Settings
Chapter 3

Chapter 3
Settings
Operating Instructions 3-2
1. SETTINGS
1.1. Setting image for N-8000 side and SIP telephone side, and a main of SIP Gateway
There are 3 steps of setting which are setting of N-8000 system, setting of SIP system, and setting of SIP
gateway.
1.2. Setting of N-8000 system
This N-8000 SIP Gateway is to be set as a N-8000EX and 5 N-8000MS, virtually.
The following is an example of a setting for SIP Gateway.
Note: This Equipment No. of virtual N-8000EX is used for the setting of SIP Gateway.

Chapter 3
Settings
Operating Instructions 3-3
1.3. Preparation for and
The following is a window of SIP Gateway.
Settings are by a clicking File, there are menu of B: “SipClientSetting” and C: “SipGatewaySetting.”
1.4. Preparation for SIP Client setting
Connecting to SIP system, the following info. is needed.
No. Item Comment
1 IP address of SIP Server
-
2 SIP Port of SIP Server Default is “5060”
3Extension number for SIP Clients SIP Gateway can have 5 SIP Clients
4SIP device prole Password requirement, and a method of Authentication can
be set.
Registration command to a SIP server is executed right after starting this software up, and by every 140
seconds.
SIP Gateway Setting
<SIP Server>
IP address = 192.168.1.100 (e.g.)
Port for SIP = 5060 (e.g.)
SIP Server
IP address = 192.168.1.100 (e.g.)
Port for SIP = 5060 (e.g.)
Every 140 sec.

Chapter 3
Settings
Operating Instructions 3-4
1.5. SIP Client Setting
HereisforallaboutSIPsystem.
Step 1. Setting for SIP Server. The port number with 5060 is a default of SIP protocol.
Step 2. SIP virtual Client telephone number which is registered to SIP server.
Step 3. A password for a SIP virtual Client for an authentication.
Step 4. Settings of IP address and RTP port for each virtual SIP client.

Chapter 3
Settings
Operating Instructions 3-5
1.6. SIP Gateway Setting
Step 5. A location of N-8000 setting le which is <system name>.pi8 le.
Step 6. Waiting time for specic dialing from N-8000 or SIP telephone. After this time, SIP Gateway connects
automatically to a certain station which is set in 4 for calling from N-8000, or in 5 for calling from SIP
telephone.
Step 7. N-8000 equipment number, these should be matched to a setting of N-8000Next setting le selected
in 1.
Step 8. Connecting N-8000 number which is called from SIP telephone side. Each virtual SIP Client has an
individual target of N-8000 station.
Step 9. Connecting SIP telephone number which is called from N-8000 side. Each virtual N-8000 station has
an individual target of SIP telephone.

Chapter 3
Settings
Operating Instructions 3-6
1.7. Setting example of N-8000 SIP Gateway
The following is an example of a setting that N-8000’s call to SIP.
[System example]
[Setting example]
When N-8000 side calls 801, N-8000 SIP Gateway connects to 2001 and 3 speech paths are prepared for this
function, and when N-8000 side calls 804, N-8000 SIP Gateway connects to 2005 and 2 speech paths are
prepared for this function.
N-8000 station N-8000 setting content Setting of N-8000 SIP Gateway
801 802 is for “Group-hunting” virtual SIP client 1 has 2001 in SipGatewaySetting
802 803 is for “Group-hunting” virtual SIP client 2 has 2001 in SipGatewaySetting
803 virtual SIP client 3 has 2001 in SipGatewaySetting
804 805 is for “Group-hunting” virtual SIP client 4 has 2005 in SipGatewaySetting
805 virtual SIP client 5 has 2005 in SipGatewaySetting
When SIP telephone calls 3995, N-8000 SIP Gateway connects to 101 and 2 speech paths are prepared for
this function, and when SIP telephone calls 3997, N-8000 SIP Gateway connects to 102 and 2 speech paths
are prepared for this function, and when SIP telephone calls 3999, N-8000 SIP Gateway connects to 103.
SIP extension SIP client setting content Setting of N-8000 SIP Gateway
3995 3996 is for “Busy transfer” virtual N-8000MS 1 has 101 in SipGatewaySetting
3996 virtual N-8000MS 2 has 101 in SipGatewaySetting
3997 3998 is for “Busy transfer” virtual N-8000MS 3 has 102 in SipGatewaySetting
3998 virtual N-8000MS 4 has 102 in SipGatewaySetting
3999 virtual N-8000MS 5 has 103 in SipGatewaySetting

Chapter 3
Settings
Operating Instructions 3-7
[Example of N-8000 Setting software, N-8000 SIP Gateway software]
In the N-8000 Setting software, N-8000 SIP Gateway is set as N-8000EX. IP address and port is for a PC that
N-8000 SIP gateway software is installed.
Note: In the later step, equipment No. will be used.
The next is setting for virtual N-8000MS. Line 1 to 5 are used for N-8000 SIP Gateway, 801 to 805 are set
according to this example.

Chapter 3
Settings
Operating Instructions 3-8
This is for the function that calling to 801 in the N-8000 system has 3 speech paths that goes to 2001 in SIP
system.
The following example is a setting for 801 to add 802 in the box of “Group hunting to.”
Additionally a setting for 802 is needed to transfer to 803. While 804 in the N-8000 system connecting to 2005
in SIP system needs 2 speech paths, then a setting for 804 needs to have 805 in the box of “Group hunting to.”
After all setting, a setting le shall be exported. As shown below.

Chapter 3
Settings
Operating Instructions 3-9
The next step is a setting of N-8000 SIP Gateway.
N-8000 SIP Gateway uses a N-8000 Setting le that is <system_name>.pi8. Then the equipment No. that is
programmed in the N-8000 Setting software (in this example, it’s 3). In the left with “Transfer Number” requires
numbers that N-8000 SIP Gateway connects to N-8000 system side by a request from SIP system. The right
box for “Transfer Number” is for SIP telephone number that N-8000 SIP Gateway connects by a request from
N-8000 system.
A setting of SIP server is also needed.
All SIP server has a different way for the setting, therefore the following is just basic setting contents.
· 5 SIP clients for N-8000 SIP Gateway shall be prepared. Extension numbers shall be 3995 to 3999 for this
example.
· Passwords for each extension numbers are set.
Finally SIP server setting is needed for N-8000 SIP Gateway setting. That can be done by selecting from a
menu of “File/SipClientSetting.”
That’s all.
Other manuals for N-8000 SERIES
5
Table of contents
Other Toa Gateway manuals
Popular Gateway manuals by other brands

ZyXEL Communications
ZyXEL Communications Unified Security Gateway ZyWALL 300 user guide

IXXAT
IXXAT CME/PN Hardware manual

ZyXEL Communications
ZyXEL Communications P-662HW-D - V3.40 Support notes

InHand
InHand IG601 user manual

Zte
Zte zxmsg 5200 Technical manual

HMS Networks
HMS Networks Anybus Wireless Bolt CAN user manual