Toa IP-1000 Series User manual

Operation Manual
IP PoE Horn Speaker
SC-PE630IP1
Thank you for purchasing TOA IP-1000 series products.
Please carefully read the instructions in this manual to ensure long-term and fault-free operation of the equipment.
TOA Corporation

Chapter 1
Safety Precautions

1-1
Chapter 1 Safety Precautions
Please observe the warnings and safety instructions.
After reading this manual, please properly place it for easy access and reference in the future.
Warning
This sign indicates that potential safety hazards would occur if the equipment is opened for operation
and serious injury or death would be caused to non-professionals who do not operate the equipment
properly.
This sign is used to alert users that the information attached to the equipment includes important
instructions of operation and maintenance (repair).
At setup and installation
(1) Preventing from water
Do not expose the equipment to rain or environment possibly contaminated by water or other liquids, or a
fire or electric shock may be caused.
(2) Applying the specified supply voltage
Be sure to apply the voltage indicated on the equipment.
If a voltage higher than the indicated voltage is applied, a fire or electric shock may be caused.
(3) Protecting the power cord
Do not scratch, cut or twist the power cord.
In addition, the power cord should be away from heating bodies. Do not place heavy objects (including the
equipment itself) on the power cord, or it may cause a fire or electric shock.
At operation
(1) In case of exceptions
Immediately cut off the power supply in case of the following exceptions during operation and contact the
dealer. If it continues to be used, a fire or electric shock may occur.
• Smoke or smell.
• Water or foreign bodies intrusion.
• Fall or case damage.
• Power cord damage (core is exposed or cord is broken).
• Unable to access to network or free of sounds, etc.
(2) Do not open the equipment or transform it.
Do not drop foreign bodies into the equipment.
Do not drop foreign bodies like metal or flammable objects into the equipment, or a fire or electric shock
may be caused.
(3) No touch at lightning
Do not touch the equipment and plugs at lightning to avoid electric shock.
(4) Do not place containers containing liquid or small metal objects above the equipment.
If a container is accidentally knocked over and the liquid flows into the equipment, a fire or electric shock
may be caused.

1-1
(5) Do not open the equipment or transform it.
High-voltage parts are installed in the equipment. If the equipment is uncovered or transformed, a fire or
electric shock may be caused. All maintenance and internal transformation of the equipment should be
performed by professionals.
(6) Precautions when maintenance or not used for a long time
When maintenance is performed or the equipment is not used for 10 days or more, shut off the power and
pull out the plug to ensure safety. If failing to observe this provision, a fire or electric shock would occur.

Chapter 2
Product Description

2-1
Chapter 2 Product Description
2.1 Overview
2.1 Overview
SC-PE630IP1 is an IP PoE horn speaker and can receive the broadcast from other terminals or servers supporting
the setting of functions through browser. It can detect circuit faults and operating state of the speaker and
display them on the server software.
(1) Receiving broadcast sounds
SC-PE630IP1 can receive broadcast sounds from servers or other terminals.
(2) Time program broadcasting
It can upload the sounds required to be broadcast at various periods each day to the server and prepare
plans for broadcast. SC-PE630IP1 can achieve automatic broadcast according to the tasks scheduled by the
server.
(3) System setup through browser
Users can set up network,audio parameters and modify login password of the speaker through browser to
achieve personalized settings.
(4) External Power Supply Input
SC-PE630IP1 can be powered via PoE or external DC24V power.
(5) Audio check
SC-PE630IP1 has a self-detection function and can detect the operating state of the speaker through circuit.
(6) Indicator light of operating status
SC-PE630IP1 is equipped with indicator lights of operating status and can quickly detect the operating state
of the speaker by recognizing the color and flashing of indicator lights.

3-2
Chapter 2Product Description
2.2 Terminal description
Open the back-box cover, the relevant interface meaning is as follows:
①Power Input connector: DC24V/2.7A is required, power supply input for network wall speaker. (Note: This
equipment supports POE power supply. If the network interface is connected to POE switch, no power supply is
needed)
"+" indicates the positive pole of DC24V, and "-" indicates the negative pole of DC24V power supply.
②Not used: There is no function.
③Network connector: The connector is RJ-45 standard, insert the network cable to connect the switch, so that
the equipment can login to the server normally. The network interface is equipped with two-color (green, orange)
indicator light, which can indicate the working status of the network wall-mounted loudspeaker. (Note: This
equipment supports POE power supply. If the network interface is connected to POE switch, no power supply is
needed)
Operating state
Indicator light
Power
-
on
The Orange light is ON
.
Network connection successful
The Green light is ON.
Receiving broadcast
The green light
is flashing.
Note: The Power Supply Input and Extended Speaker output interface are connected through 3.5-4P
terminal-block. The wiring steps are as follows:
Orange
Green
Power Input
Not used
Rear view
①
Loo
sen
-
up
③Tighten
②Insert cables
Terminal
-
block
(3.5
-
4P)

3-2
Chapter 3
Wiring

3-2
Chapter 3 Wiring
3.1. Installation instructions
Note: This product only guarantees the waterproof performance of wiring when using POE power supply.
If the power adapter is used for power supply, please wrap the power cord and the mesh wire with
waterproof tape to connect after passing through the waterproof plug. This wiring mode may affect the
waterproof performance of the equipment.
3.2 Reference dimensions
Step1: First a network cable is to be put through a
water-proof cover before an RJ-45 plug is assembled.
Network
cable
Water-proof
cover
Step2: ①The water-proof cover is set to a back case
②An RJ-45 plug is connected to the connector.
Touching an RJ-45 plug may
damage a water-proof cover.
Step
3
:
Fix a back case to the back
-
box.
Step
4
:
Install SC
-
PE630IP
1 to a proper place.
Adjust a proper angle, then
fix a bracket with proper
bolts.
(Bolts are to be prepared.)
Rear view
Front view
Side
view
Bracket’s installation dimensions:

Chapter 4
System Setup Through Browser

4-1
Chapter 4 System Setup Through Browser
4.1 Access to browser
Step 1 Enter the IP address of SC-PE630IP1 (the default IP is 192.168.1.101) in the address field of IE
browser and press ENTER.
Step 2 Enter user name and password (the defaults are admin) in the login window on the Web page.
Note: User name and password are case sensitive.
Step 3 Press the OK button and then enter the Web page of SC-PE630IP1.

4-2
Chapter 4 System Setup Through Browser
4.2 Net options
Terminal IP
IP address of
SC
-
PE
630
IP1
(the default is 192.168.1.101)
Subnet mask
Used to set the subnet mask (the default is 255.255.255.0).
Default gateway
Used to set the gateway of
SC
-
PE630
IP1 (the default is 192.168.1.1).
DNS
1 (Optional)
Used to set the IP address of preferred DNS server of
SC
-
PE630
IP1.
DNS
2 (Optional)
Used to set the IP address of alternate DNS server of
SC
-
PE630
IP1.

4-3
Chapter 4 System Setup Through Browser
4.3 Server Options
Terminal ID
This must be a unique number in the same system
,
do
not duplicate with
any
other terminals even for other models. The factory default ID number is 1.
Local Port
The default
terminal
port number is 2046. Do not modify it without special
circumstances.
Primary
Server
IP address of
a
primary
broadcasting server,
the
default port
is
2048
.
Secondary Server
When the
primary
server is unable to connect,
the
terminal
can login to the
secondary server. After the primary server can be connected, the terminal
login to the primary server again.
Login Interval (s)
Set the interval
time
in seconds
that
SC
-
PE630
IP1 requests to log
i
n to the
server.

4-4
Chapter 4 System Setup Through Browser
4.4 SIP options
SIP
Select
for this activation.
SIP Server
The SIP server address where the
terminal
is located, please fill in the IP
address or domain name of the SIP server correctly. The port should not be
modified, except in special cases (default is 5060).
Account
The SIP account of the
terminal
. This
should
not be duplicated with
any
other
terminals. This account number has to be set in the SIP server side.
Password
The
terminal
login
to a
SIP server
with this
password
. This password has to
be matched to the password which is set in the SIP server side.
Local Port
Configure the local port according to the actual situation.
Audio Port
Configure the audio port according to the actual situation.
Multicast
Contact
Select for this activation.
Multicast Address
In the case of mult
iple
servers in LAN, different servers must
use
different
addresses and port numbers for escaping any interference.

4-5
Chapter 4 System Setup Through Browser
4.5 Audio options
Broadcast Volume
The total volume of the audio output of the
terminal
during broadcasting
.
The value is from 0 (smaller) to 15 (louder).
Buffer time
This is for stable broadcasting output adjustment. When this value is small,
audio latency is small and it’s better for a live paging however if the network
is unstable, its audio would be so choppy. When this value is big, audio
latency is longer and it’s probably acceptable for a live paging in case that a
speaker (who makes announcement) is in a different location and this
situation is normal. And this big buffer makes its audio more stable.
Audio check
When the real
-
time noise of the
terminal
is less than or equal to the average
noise, the server will display the fault information by bouncing window.
Disabled for not enabling Audio check function;
Dynamic volume
adjust
When dynamic volume adjustment is enabled, the
terminal
will adjust the
output volume of broadcasting according to the noise level.
When disabled, the dynamic volume adjustment function is invalid, and the
"running status" page of the web page displays the real-time volume level.
Noise detect adjust
(dB)
Setting the noise detection
adjustment
value (default is 16 dB), the larger
the value, the larger the real-time noise value detected.
Note: The noise detection adjustment value = the noise decibel value
measured by the decibel meter when the calibration value is 0 - the average
noise decibel value detected by the terminal.
Noise
Reference(dB) Normal environment, noise average decibel value, default to 60 dB
Noise
detect
interval (s)
Set the average noise detection interval time
in second
, default is 30
sec
.
.
The average noise varies according to the setting time.

4-6
Chapter 4 System Setup Through Browser
4.6 Password Setting
Users can modify login account and password in the web management parameters.
Original usern
ame
Confirm the current account name.
Original
p
assword
Confirm the current password.
New
usern
ame
Set the new account name, even this isn’t needed,
this should be set.
New
p
assword
Set the new password.
Password
Confirm
Confirm the new password.

4-7
Chapter 4 System Setup Through Browser
4.7 Language Setting
The language of the web page can be switched between Chinese and English.
If the language setting is set to Chinese, the following is a position of “Language Setting”.

4-8
Chapter 4 System Setup Through Browser
4.8 Update firmware
Press the "Update" button. Firmware upgrade mode will be entered in 15 seconds. Click "Browse", select
the upgrade file provided by the manufacturer, and press "Update" to start firmware update.
Note: Do not turn off the power during upgrading the terminal, otherwise it may lead to the failure of the
upgrade and the failure of the equipment.

4-9
Chapter 4 System Setup Through Browser
4.9 Restore factory settings
Restore factory settings: All parameters are restored to factory settings.
Factory reset

4-10
Chapter 4 System Setup Through Browser
4.10 Reboot
Users can click the menu "Reboot" to restart SC-PE630IP1.
Other manuals for IP-1000 Series
4
This manual suits for next models
1