6.Remounting covers,and lockit.
3.Pushoutthe frontcoverfrombackcover.
5.Placefrontcoverintothe mounting holeof
backcover.
Installation structions
SelectWide lensmode
1.Unlocktheswitch.
2.Prizeup the jointline bet-
ween frontand back cover
withablade screwdriver.
4.1preventreflectorfromdustofdrilling hole,
pleaseremovereflectorwhenmounting back
cover,avoidyourhandscontactingreflector’s
surfacewhenremovingormountingreflector,
onlyblowoff themorwipe off themslightly
withsoft clothafterfounding dustnotother
thingsforkeeping betterdetection effect.
4.2connectthe wirestoterminal,observe
connection polarity
4.3Don’tletyourhandscontactinfrared
sensor.
EL-208 can useinCurtainlens
detection mode,butascurtainlens
mode,mustchange singlewide
lensintocurtainlensanglelens.
Removing the curtainreflector,pleaseholdreflector’stop .pull emissivemirror
outwards.
When uninstalling,holdon theuppertwosidesofthe mirror,pull the mirrorout,following phaseofright
figureinoppositedirection.Installation:pushcurtainreflecting mirrordownintobottomrind.Pleaserefer
torightfigure.Notice:makesurethe position ofbottomofthe
curtainreflecting mirrormustabsolutelyfitintothe bottomrind.
Pleaserefertopartofthe figure.Horizontallypushcurtainreflect-
ing mirrorintothe detector.Pleaserefertorightfigure
Notice:afterinstallation,makesurethe curtainreflecting mirror
isstable,don’ttouchthe mirrorwhen installing.
Installation
Note:Onlyapplypowerafterall connectionsaremade and inspected.And makesurethe power
polarityiscorrect14-22AWGwireisrecommended.
Note:Donotleavetoo long wireinthe detector.
TerminalsV+&V-: Powerinput, Voltage:9-16V.The max
distanceisupto250m/750feetbetweenthedetectorandpower
sourceifusing wire#22AWG.
TerminalsC&NC:Alarmoutput. 30VDC/150mA.Max
TerminalsT1&T2:Tamperoutput, N.C,24VAC/500mA.
12V/DC
Zoom
Input
ControlPanel
V+
C
GND
30cm
60cm
80cm
Note:pleaseinstall the
detectoron wall,the
placeshouldbe one
meterorhigher.
For curtain lens For PatioFor wide lens