Tormach, Inc.
P: 608.849.8381 / F: 209.885.4534
tormach.com
TECHNICAL DOCUMENT
Page 2
©Tormach® 2019. All rights reserved.
Specicaons subject to change without noce.
TD10383_Touch_Screen_Kit_0919A
3. Line up VESA Mount Plate with Touch Screen
Monitor and aach as follows (see Figure 2):
• Use two M4 x 10 mm Machine Screws on
the upper two screw holes
• Use two M4 x 10 mm Thread-forming
Screws on the lower two screw holes
4. Connect USB, SVGA, and power cables to
monitor.
5. Route cables to Square Tube Arm (see Figure
3). Aach cables to Wire Tie Mounts with
Cable Ties (see Figure 3).
6. Connect power cable to monitor’s Power
Transformer.
7. Mount Power Transformer on clean machine
arm surface in locaon A as shown in Figure
3 using two Cable Tie Holders and two Cable
Ties.
8. Route USB, SVGA, and power cables through
cable slots in Square Tube Arm (see Figure 3).
9. Connect USB cable from monitor to USB
Extension Cable and SVGA cable from monitor
to exisng SVGA extension cable; route both
extensions to controller and connect.
NOTE: USB connecon can be made via any of the
USB connectors the controller.
10. Route and connect monitor’s power cable to
the machine.
Figure 3
Square
Tube Arm
Round
Monitor Post
Wire Tie
Mounts
and
Cable
Ties
Machine Arm for Enclosure
A
Figure 2