
. 0-2650-9925, 09-2246-5880
() 77 5 .. .18140
For more information
Please contact, Tel. 0-2650-9925, 09-2246-5880
TOTO MANUFACTURING(THAILAND) CO. LTD 77 Moo 5, Nong Plamor, Nong Khae, Saraburi 18140
271114
/
Air-in / Hand Shower Set (Air in Shower)
/ Model No.
TTSH103CK, TTSH103ECFK,TTSH103ECFUK
TTSH103C, TTSH103CF, TTSH103ECF,TTSH103ECFU
TTSH103CH, TTSH103CFH, TTSH103ECFH, TTSH103CFUH, TTSH103ECFUH
, Hand shower (Air in Shower) ,
Thanks for your recent purchase of the Hand Shower (Air in Shower). Please read the Manual thoroughly and follow
all instructions.
1. / Important Safeguards
() / (For your safety, please follow the instructions below.)
Read these important safeguards instruction thoroughly before using your product and follow the precaution instructions carefully.
In this instruction manual, the following symbols are shown for safe and proper use of your product and in order to alert you to the possibility of personal injury
and damage to your property. The symbols and their meanings are as follows
Ignoring these symbols may cause personal injury and/or property damage
Warning
. .
.
/ Warning
,
Do not modify this products or set up other parts. If the faction of product is damaged may be injured or damaged to property.
(60) 45
The shower not use hot water (Over 60°C ). Damaged to shower and injured while take a shower. Keep temperature not over
45°C.
, ,
Before cleaning the filter, please close the valve and check in the shower have hot water or not? If have hot water may be injured or
damaged to property.
, .
Before use hot water, check appropriate of temperature is ok or not? If hot water flow out may be injured. And beware change flow
from faucet to shower or change mode of shower.
/ Describe the isolation details to follow.
/ Some may have different components from the ones illustrated below
Prohibited
Mandatory
Over 60 °C
/
, .
Do not impact or dropped, if broken may be injured. In the cases the product is broken, change new products.
/ Plating type
,
Do not use in place can not specify the number of users. Such as compare the public bath with home, The number of usability and
install area a different. If broken may be injured.
-.
Do not use liquid cleaners with acid-base content. If use may be surface of product has been damage.
/ Beware
, ,
In the case that used in place a low temperature is expected to become ice. Take action to prevent damaged parts. Maybe damaged to property.
()
.
Do not the product about cosmetic stained shower.(Such as hair dyes, shampoo, styling gel or foam) If stained products about
plastic may be color change or damaged. In the case of stained, suddenly clean with water.
Mandatory
Do not
Do not
2. / How to use
Air in Shower,
Air in shower, Mixture of water and air at the channel of air suction. Although a little flow, watercourse is enough to take shower and feel comfortable .
After install the shower in hanger tightly and can change the angle.
In the case after close valve and water flow, Depending on the angle of the hang of the shower. In this case, adjust the appropriate.
. ,
Please set up water pressure appropriate for shower. If high pressure, may be shower move or angle move.
/ Bits of knowledge
/ Beware
Have sound of air inside the shower. Because of the conveying air into the mixture, not to damage of products.
If the high pressure water may be water drop from the channel of air suction during use. This case close valve and set pressure water to appropriate.
.
Because pending water in shower drain out. So after close valve drain out. If water drain very long time, check valve is closed end or not?
5-10
In the case need pending water in shower drain out. Shake carefully 5-10 times. Please see right picture.
.
Do not impact or dropped. Maybe parts in side of shower is damage and function of shower is unusual.
/
/ How to prevent a frozen
() / (In case used in place at risk for was frozen.)
3.
, .
The shower was frozen The parts will be damaged, causing water leakage.
, , ,
In cases where the risk for was frozen, Avoid the ambient temperature is below freezing. In case temperature is below freezing, proceed as follows.
Shower Head
Shower Hose Below
510
510 time
Minus screwdriver
Valve
Small Volume
Big Volume
Drainage the residual water
Shower Head
Shower Hose Below
5-10
5-10 Times
5-10
To avoid the pending water freezes into ice.
Shake carefully 5-10 times. Please see left picture.
/ Maintenance
4.
,
For performance, and for hygiene. Please clean regularly
4-1 / Cleaning the channel of air suction.
()
Ventilation hole
() ,
,
If the channel of air suction is clogged, Maybe performance is not fully or cause pending
water not drain. Cleaning by brooch.
/ Beware
AIR in shower,
-
Do not soak in water, whether it is a bathtub or basin.
-
Do not soak cleanser
Air in shower
If Air in shower is soak in water, Maybe sucked cleanser or hair or garbage into the channel of air suction. May cause
a clogging.
Ventilation hole
/
4-2 / Cleaning the filter.
Shower Head
Tighten
/Shower Side
/Shower Hose Side
Filter
Filter
Toothbrush
1.
Close Valve
2.
Take off the filter, by take of the shower head with
shower hose.
3.
Cleaning the filter be dirty by Toothbrush.
4.
In put the filter.
Beware about installation of the filter.
The product is a plastic
shower, Carefully drop may
cause damage thread.
4-3 / Cleaning the filter.
Nozzle
Water flow not completed, caused by a clogged of nozzle. Cleaning by
Warm clothes and beware scratch to nozzle. If use very strong may be
nozzle is damage or shape of nozzle damage and water flow clogged or
scatter.
/ Request
Please do not take things that damage.
・
TOTO
,
・If use the addition of a neutrality cleanser and cleanser of TOTO
Maybe surface plastic of shower is damage.
・,
・Solvents such as thinner, benzene may be made of plastic or rubber
parts that are damaged.
・,
・Cleaner, polish the rough powder.
・, ,
・Nylon, stiff brush, toothbrush can cause scratches to the shower.
5. ? / Indication is damage?
, .
The following case, not damaged. Before calling a technician to check active. "Instructions for use" of the product, and if not, please report. Repair to the shop
Dealer or customer service after the sale.
/ Before calling the technician. The following should be checked.
/ Problem / Check Point / Solution
/ Water is
run non stop
/ The water flow is not
Smooth
/ Low flow
rate
, .
Water retention in the shower, the water will out from inside shower. No problem.
?
The nozzle are clogged or not?
?
The filter are clogged or not?
Cleaning the Nozzle
/ Refer
4-3
4-2
0M310
/ Plating type
Beware about
installation of the filter.
Cleaning the Filter