ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
6 of 12
Make sure that wall plate (K) is level, use it as a
template to mark four mounting holes. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (65 mm).
Insert anchors (H) in holes flush with wall as shown
(right).Placewall plate over anchors and secure with
four #14 x 2.5" screws (G) and fender washers (V).
Level,thentightenallfasteners.
Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breakingout the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Makesure that the supporting surface will safely support the combined load of the equipment and all attached hard-
wareand components.
WARNING
CONCRETE
SURFACE
1
3
2
H
Drill holes and insert anchors (H).
Place plate (K)over anchors (H) and secure with screws (G)
and fender washers (V).
Tighten all fasteners.
KH
G
CUTAWAYVIEW
INCORRECT
CORRECT
wallplate
plaster/
drywall
concrete
wallplate concrete
plaster/
drywall
• Always attach concrete anchors directly to load-
bearingconcrete.
• Neverattach concrete anchorsto concrete covered
withplaster,drywall, or other finishing material. If
mountingto concrete surfaces coveredwitha finishing
surfaceis unavoidable, the finishing surfacemust be
counterboredas shown below.Be sureconcrete
anchorsdo not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
• Tighten screws so that wall plate is firmly attached,
butdo not overtighten.Overtightening candamage
screws,greatly reducing their holdingpower.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
G
K
V
SOLIDCONCRETE
CINDERBLOCK
H
V
• Always attach concrete anchors directly to load-
bearingconcrete.
• Neverattach concrete anchorsto concrete covered
withplaster,drywall, or other finishing material. If
mountingto concrete surfaces coveredwitha finishing
surfaceis unavoidable, the finishing surfacemust be
counterboredas shown below.Be sureconcrete
anchorsdo not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
2