UNIT STARTUP AND PRINCIPAL OF OPERATION:
1. Connect power cord to input receptacle. Plug cord into 120V outlet to power up unit.
2. Display will show 0.0A, while green status LED for channel 1-4 will illuminate in sequence indicating the outlets
1-4 are active and available to charge.
3. Connect loads to the outlets. If a load draws power (like a battery that needs a charge), the active LED for that
channel will display red.
4. As loads draw current, the display will indicate total load drawn through the PDM.
5. As loads are attached, if the load for the last channel connected results in total unit draw to exceed 16A, the
relay for that channel will open. This will be evident by both the green and red LEDs for the channel going off.
6. Continue to plug in loads to the outlets as needed.
7. As charging is completed and the overall unit current level draw drops sufficiently, open relays will close to allow
charging for channels previously opened.
8. Note: All loads can be connected to outlets at anytime prior to or during unit startup. Procedure outlined above
is suggested only to illustrate principal of operation.
CONNECTING UNITS TOGETHER TO EXPAND SYSTEM CAPABILITY
NOTE: 4-channel units can be connected to expand power management from 4 to 8, 16 up to 32 loads off a
single 120V line.
1. Identify PDMs to be combined under a single power management. Units under single power management are
limited to a total current draw of 16A no matter the total number of units that are connected.
2. Select a convenient PDM and connect it to a second PDM via an RJ545 patch cable. Connect the cable into the
first unit at the LINE port. Connect the other end of the ethernet cord to the second unit at the LINE port.
The first 2 PDMs are in a daisy chain control configuration and will manage 16A of power across the 8 total
outlets available between the 2 units.
3. Additional PDMs can be attached to the first 2 units buy connecting the LINE port of the last unit connected
in the daisy chain to the LINE port of the next unit.
4. As indicated in the figure below, connect one of the PDMs to input power. Using the Daisychain port of the
first unit, connect power from the first unit to the second unit input port. Daisychain input power to all
digitally connected unit as indicated in figure below.
5. Once daisychained units are digitally connected and powered up, all LED current displays will show 0.0A to
0.3A on the total load display and the ACTIVE green leds will illuminate in sequence running channel 1-4 for
the first unit connected, then channels 5-8 for the second unit, etc.
6. Loads can be connected anytime during the startup to any of the connected PDMs.
7. The connected PDMs will limit overall current draw to 16A. Switching operation for connected units is the
same as for independent PDMs.
Towa
Industries,
Inc
/
480
E
McGlincy
Ln,
Campbell
CA
95
008
/
650.204
.0019
/
[email protected]Indicated presence of potentially harmful
electrical shock hazards. De-Energize circuit
and consult instruction prior to operation.
Specifications:
Input –120V 50/60 Hz NEMA 5-20P 20A
Output –120V / 16A total, NEMA 5-20R
Dimensions – 12” x 7” x 2” Ver –October 11, 2022
Plug into input power
from 120V/20A here
Use expansion port
to daisy chain input
power to connected
units.
Input port
Expansion port
Daisychain
Daisychain
Daisychain