Altinex UT240-600 User manual

UT240-600 Power + AV Distribution Plate, 1U User’s Guide
400-0832-001
1
Welcome!
Everyone at Altinex greatly appreciates your UT240-600
purchase. We are confident you will find it to be reliable and easy
to use. If you need support, do not hesitate to call at
714-990-2300.
We are committed to developing unique, state of the art Signal
Management Solutions® for demanding audiovisual installations.
Welcome to Altinex’s family of satisfied customers worldwide!
1. Precautions and Safety Warnings
Please read this manual carefully before using your
UT240-600 Power +AV distribution plate, 1U. Keep this
manual handy for future reference. These safety
instructions are to ensure the long life of your UT240-
600 and to prevent fire and shock hazards. Please read
them carefully and heed all warnings.
1.1 General
Qualified Altinex service personnel or their authorized
representatives must perform all service.
1.2 Installation
Place in a dry area away from dust and moisture.
To prevent fire or shock, do not expose unit to water or
moisture. Do not place in direct sunlight, near heaters or
heat-radiating appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm internal
components.
Handle carefully; dropping or jarring can damage the unit.
Do not pull any cables that are attached to the UT240-600.
Install all cables according with the instructions.
1.3 Cleaning
Clean surfaces with a dry cloth. Never use strong
detergents or solvents such as alcohol or thinner. Do not
use a wet cloth or water to clean the unit.
1.4 FCC Notice
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and if not installed and used in accordance with
instructions found herein, may cause harmful interference to
radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in
which case the user will be required to correct the
interference at his own expense.
Any changes or modifications to the unit not expressly
approved by Altinex, Inc. could void the user’s authority to
operate the equipment.
2. Installation Procedures
The UT240-600 is 1U high plate for use in 19” wide mounting rack, multimedia podium, wall-mount rack, etc.
Step 1. Locate position for the UT240-600, but do NOT install until cables are ready.
Step 2. Prepare cables/connectors for ports using high-quality components for
best results and durability. Make cables long enough to allow for service
and routing. Do NOT allow cables to just hang from the UT240.
Step 3. For XLR connectors/cables, remove keystone adapters
installed in the port openings by removing M3 nuts and
screws (two each) from the back of the plate.
Step 4. For USB charging ports, install the dual USB charger
provided with the unit into the rear AC socket. Connect
the two USB cables provided to the USB 2.0 couplers
installed in the plate.
Step 5. Secure the unit to the mounting rack using the four screws and
four washers provided with the unit.
Step 6. Make any necessary connections to the ports.
Step 7. Connect the unit's power cable to a power outlet.
Step 8. Use custom labels by writing name and applying it into recess above required port if needed.
3. Limited Warranty/Return Policies
Please visit the Altinex website at www.altinex.com for details on warranty and return policies.

UT240-600 User’s Guide
400-0832-001
2
4. Technical Specifications
Specifications are subject to change. See www.altinex.com for up-to-date information.
Features/Description UT240-600
Pass-Through (front to back)
AC Power 3x NEMA Receptacle to plug
3 ft. (0.9 m) cord
USB 2.0 USB bulkhead, F-F
connector (2pcs)
Audio/Video Six Empty ports for custom
cable/connectors
Agency Approvals
Ul/CUL Listed File E254082
Accessories Included
USB Wall Adapter Dual USB out charger
(5V, Total 3.4A)
USB Cable 2.0 USB A-M to A-M (1ft)
(2pcs)
Custom Label Blank labels
Cover Blank black snap-in cover
(6pcs)
Mounting Hardware 10-32 Screws (4pcs)
#10 Washer (4pcs)
Table 1. UT240-600 General
Mechanical UT240-600
Material Steel
Finish Black
Dimensions (W x D x H) 19 x 5.1 x 1.75 in
(483 x 130 x 44 mm)
Shipping Weight 2.1lb (0.95 kg)
T Operating [T Maximum] 10C-35C [50C]
Humidity 90% non-condensing
Table 2. UT240-600 Mechanical
Electrical UT240-600
Pass-Through AC
12 A max.
(total through all 3
receptacles)
Table 3. UT240-600 Electrical

UT240-600 User’s Guide
400-0832-001
3
5. About Your UT240-600
1U high, full rack wide
Black finish
Three AC sockets (12 amps total)
3 ft input power cable
Eight Keystone type ports
All ports are XLR compatible
Six blank covers for unused ports
Two port USB charger with US plug
Two 2.0 charging USB A/A Keystone couplers
Two USB A-M to USB A-M (1 ft) cables
Custom labels available with additional cost
Rack mounting hardware included
UL listed
The UT240-600 is a 1U high full rack wide power/charging plate for AV racks. There are three power sockets providing up to
12A total power. Two power sockets are located on the front side of plate for convenient access. One power socket and a
single power cord are located on the back side of the plate.
Two of the eight customizable ports are designed as USB charging ports. Just install the dual output USB charger (5V, Total 3.4A
Output) provided with the unit into the rear AC socket. Then, connect two USB 2.0 couplers to the USB charger using the USB cables
(USB A-M to USB -M) provided with the unit.
All eight ports can be easily customized in the field using different types of connectors and/or cables. Simply remove the blank covers
and then install Keystone ports. All port openings are compatible with XLR type connectors or Keystone snap-in connectors.
For XLR connectors, remove a keystone adapter connector installed in one the port openings. To do this, remove M3 nuts and screws
(two per each port) from the back side of the plate. The removed hardware can be used for installation of XLR connectors.
The UT240-600’s unique design allows users to reposition or remove the magnetic labels. There are 20 blank magnetic labels provided
with the unit. Write the name of your custom port on the label. Apply labels into the recessed areas above the snap-in ports. Preprinted
custom magnetic labels are available at an additional cost.
For your convenience, UT240-600 accessories include 4 size 10-32 screws and 4 size 10-32 washers for rack mounting the unit.
UT240-600 shown here.

UT240-600 User’s Guide
400-0832-001
4
6. Application Diagrams
Diagram 1: Typical Setup

UT240-600 User’s Guide
400-0832-001
5
Diagram 2: Dimensions
Top View
Front View
Side View

UT240-600 User’s Guide
400-0832-001
6
Diagram 3: Installation Diagram

UT240-600 User’s Guide
400-0832-001
7
7. Operation
The UT240-600 requires no adjustments for performance. Once set-up, the UT240-600 will work trouble-free without user intervention.
8. Troubleshooting Guide
We have carefully tested and found no problems in the supplied UT240-600; however, if you experience any problems or have
questions, call Altinex at (714) 990-2300.
Table of contents
Other Altinex Power Distribution Unit manuals
Popular Power Distribution Unit manuals by other brands

Eaton
Eaton ePDU G3HD Installation and connection manual

Synergy Global Technology
Synergy Global Technology RA5024-520-20A-L520 General information

Vertiv
Vertiv GEIST UU30009L Quick installation guide

Rockwell Automation
Rockwell Automation Trusted T8297 manual

DONGAH ELECOMM
DONGAH ELECOMM CPRS-1400 installation manual

Siemens
Siemens SIPROTEC 7XR81 manual