Please read the instructions before installing!
•Movement sensors should be preferably installed by a trained electrician who can understand the
installation procedure and guidelines.
•Ensure wires are properly connected with reference to phase, neutral and load.
•Concentrated Light from IR emitting fluorescent lamps should not fall on the sensor window, which
may disturb the sensing operations. As such ensure a minimum distance of around 3 meters between
the florescent lamp and the movement sensor.
•Install the movement sensor only at the specified height
•Install the movement sensor in such a way that the detection range is angled across the movement.
•Use only transformers/Ballast made to IEC or equivalent standards by manufacturers of repute.
•If required connect 2.2uF/440V AC Fan Capacitor across CFL with electronic ballasts to avoid blinking
in OFF state.
•Connect upto specified wattage of load only. For higher loads suitable rated contactor of reputed make
can be used.
•Hindrance / moving object should not hide the detection window.
•Avoid installing in Bathrooms. Make sure air conditioners, central heating, etc.do not cloud IR window.
INSTALLATION OF MOVEMENT SENSOR– Steps:
1. Turn OFF power through a switch or MCB.
2. Remove the front plate and mounting screws.
3. Connect the movement sensor as per the wiring diagram shown below.
4. Form wires carefully into the metal box, mount and align the movement sensor.
Note: Standard metal box or surface mount plastic box of 2-module size (75mm X 75mm) to be used.
5. Carefully screw the unit on to the box and click the front plate.
6. Turn ON the power.
WIRING DIAGRAM OF MOVEMENT SENSOR:
NEUTRAL
PHASE
TO LOAD
LOAD
Note: Use 0.75 Sq.mm.flexible wires for connections (Phase, neutral & load)