Trace Engineering 2500 Series User manual

Model
2500 Series
For Homes, Boats or RVs
2,500 Watts of continuous power.
Many inverters produce “rated power” for only 15 to
30 minutes. Trace’s 2500 Series inverters are certified by ETL Testing Laboratories to produce
2,500 watts continuously. They also conserve battery energy by consuming only 1/3 watt under no-
load conditions, and by running at 85% to 96% efficient for any load over 50 watts.
The convenience of automatic operation
.
Combination inverter/charger (StandBy)
models include a built-in battery charger and automatic mode switching that provides true “set it
and forget it” operation. These units sense the availability of AC from any source (shore power,
generator or grid), and automatically switch to battery charger mode. When AC is no longer
available, they switch back to battery power (inverter mode) in less than 40 milliseconds. Best of
all, you don’t lift a finger!
Maximum battery performance.
The powerful and advanced multi-stage battery charger
built into StandBy models ensures rapid and complete charging without the risk of over-charging.
Easily adjustable controls allow you to tailor the charge program to your battery type and bank size.
Battery charge can be maintained indefinitely without the electrolyte “boil-off” problems inherent to
ordinary chargers. All models feature “smart” protection circuitry that frees all the energy your
battery bank can safely deliver, but shuts down the inverter if your battery approaches dangerous
discharge levels.
Certified for residential, commercial installation and
photovoltaic power systems.
The independent, nationally recognized
testing labs of ETL have certified the 2500 Series to Underwriter Laboratories’
specification UL1778 and UL1741, so you can easily comply with National Electric
Code (NEC) requirements.
Certified for RV installation.
All 12- and 24-volt 2500 Series inverters are ETL certified to
UL458 for RV installation, and meet Recreational Vehicle Industry Association (RVIA) guidelines.
Certified for marine installation.
Trace also offers
a marine 2500 (in the U.S. only) that meets
American Boat and Yacht Council standards
and is ETL certified to UL1236 for marine
installation. The 2500M comes standard with
all features of the 2500, plus a built-in battery
charger, four-function digital meter, and neutral switching
circuitry. Neutral switching follows ABYC standards in
providing maximum protection from electrical hazards unique
to the marine environment, whether operating from shore,
generator or battery power.
Options make Trace inverters more flexible
.
Trace’s Stacking Interface (SIB) enables two inverters to operate
as one for up to 5,000 watts of continuous power, 12,000 watts
of surge, and battery charging that’s twice as fast. A Remote
Control Panel (RC-2000) may be dash-mounted up to 50 feet
away, and has a digital readout of battery voltage, charge rate (amps), and the AC source’s line
frequency (hertz) and peak voltage. An on/off remote control (RC2) allows the inverter to be
monitored and controlled from up to 50 feet away.
The bottom line:
Trace 2500 Series inverters provide low cost, quiet, dependable AC power
wherever and whenever you need it. Contact your local Trace dealer to learn more.
ENGINEERING
2,500 watts continuous
power output
Readily handles surges
up to 8000 watts
Automatically turns on
on demand
Stand-by mode draws
less than 1/3 watt
Built-in, automatic
battery charger
Special version for
marine use
ETL certified to UL
specifications
Available in 5 battery
voltages: 12,24,32,36,
and 48.
Trace Engineering
winner of Editor’s
Choice Powerboat
Reports Magazine for
the 2500 Series
THE POWER COMPANY
INVERTER/CHARGER
®
L
I
S
T
E
D
C67664
®
Warranty 2 year parts and labor
Continuous Power* 2500 Watts 2600 Watts 2200 Watts 2500 Watts 2500 Watts
Surge Power** 8000 Watts 8000 Watts 6500 Watts 8000 Watts 8000 Watts
Efficiency 96% peak - greater than 85% from 50 watts to rated output
No Load Current
-Search Mode .030 amps .018 amps .016 amps .014 amps .012 amps
-Full Voltage .60 amps .36 amps .32 amps .28 amps .24 amps
Nominal Input Voltage 12 VDC 24 VDC 32 VDC 36 VDC 48 VDC
Input Voltage Range 8.8 - 15.6 14.9 - 30.7 19.9 - 42.9 19.9 - 47.0 22.4 - 62.6
Nominal Output Range 120 VAC (100, 220, 230, 240, VAC - 50 or 60 Hz models also available)
Voltage Regulation ±2% RMS
Frequency Regulation-60Hz ±.04% RMS
Waveform Modified Sine
Power Factor Power factor of load can vary from -1 to +1
Stacking Option Available YES
Load Sensing Sensitivity 5 to 80W
Inverter Protection Circuits:
with Auto Reset High battery, low battery, high temperature, instantaneous over-current with linear temp compensation.
with Manual Reset Extended over-current (more than 20 seconds), inverter output connected to grid or genset.
Battery Protection Circuit Load compensated, “smart” overdischarge protection
Cooling Thermally activated AC fan
Dimensions (HxWxD) 9.5 x 11.5 x 13.5
Weight Product weight: 42 - 44 lbs. Ship weight: 47 - 49 lbs.
Other Voltage/frequency specs for export are as follows: (Example 2512 /NE)
/A = 240VAC/50Hz /NE = 220VAC50Hz /J = 100VAC/50Hz /K - 100VAC/60Hz
/W = 220VAC/60Hz /E = 230VAC/50Hz /U = 240VAC/60Hz (Two wire output only)
Model
2500 Series
SPECIFICATIONS
ENGINEERING
THE POWER COMPANY
Available From:
Inverter Model Number 2512 2624 2232 2536 2548
* All power specifications based on 20°C ambient and resistive loads.
** Largest bank of incandescent light bulbs that inverter can start simultaneously and operate for at least one minute.
*** Marine/RV models (/M) standard with battery charger, digital meter and polarized AC output.
**** Specifications may change without notice.
NOTE: All Trace inverter/chargers can be made in export voltage configurations.
Automatic Transfer Relay 30 amp/1HP - switches from inverter to battery charger with 10 second delay for generator spinup
Maximum Charge Rate 120 amps 60 amps 45 amps 40 amps 30 amps
Battery Charger Program Three Stage: (1) Bulk (constant current), (2) Absorption & (3) Float (constant voltage)
Bulk Stage 0 - 120 amps 0 - 60 amps 0 - 45 amps 0 - 40 amps 0 - 30 amps
Absorbtion Stage-vdc 14.1 - 14.7 28.2 - 29.4 37.6 - 39.2 42.3 - 44.1 56.4 - 58.8
Float/ Maintenance Stage-vdc 12.8 - 13.5 25.8 - 27.0 34.4 - 36.0 38.7 - 40.5 51.6 - 54.0
Transfer to Float 0 - 20 amps 0 - 10 amps 0 - 7.5 amps 0 - 6.7 amps 0 - 5 amps
Temp Compensation Manual adjustment from 20° to 100° Farenheit
Equalize Function-vdc 15.5 - 16.1 31.0 - 32.2 41.3 - 42.9 46.5 - 48.3 62.0 - 64.4
Battery Charger (StandBy Option)***
BATTERY VOLTAGE
TIME
15
14
13
12
ABSORPTION
FLOAT/
MAINTENANCE
BULK CHARGE
100
90
80
70
% EFFICIENCY
POWER IN WATTS
0 500 1000 1500 2000 2500 3000
60
Safety Timer Limits time spent in Bulk or Equalize Mode — Adjustable 2 to 20 hours
Trace 2500 Series Inverters (60 Hertz Models)
Changing Profile Efficiency Curve
®
L
I
S
T
E
D
C67664
POWER CONDITIONING UNITS FOR
USE IN PHOTOVOLTAIC POWER
SYSTEMS STANDARD UL1741
POWER CONVERTERS AND POWER
CONVERTER SYSTEMS FOR
RECREATIONAL VEHICLES
STANDARD UL458
COMMERCIAL AND INDUSTRIAL
POWER SUPPLIES
CERTIFIED TO
CAN/CSA-C22.2 NO. 107.1-M1
ETL TESTING LABS. INC
CORTLAND, N.Y.
REV# 12/97
®
L
I
S
T
E
D
67664
POWER CONVERTERS AND POWER
CONVERTER SYSTEMS FOR
RECREATIONAL VEHICLES
STANDARD UL458
MARINE BATTERY CHARGES
STANDARD UL1236
ETL TESTING LABS. INC
CORTLAND, N.Y.
5916 195th St. N.E. ARLINGTON, WA. USA 98223 Phone (360) 435-8826 Fax (360) 435-2229 Web: www.traceengineering.com

This manual suits for next models

5

Other Trace Engineering Inverter manuals

Trace Engineering DR Series User manual

Trace Engineering

Trace Engineering DR Series User manual

Trace Engineering SW2612E User manual

Trace Engineering

Trace Engineering SW2612E User manual

Trace Engineering SW Series User manual

Trace Engineering

Trace Engineering SW Series User manual

Trace Engineering LEGEND I User manual

Trace Engineering

Trace Engineering LEGEND I User manual

Trace Engineering Mariner User manual

Trace Engineering

Trace Engineering Mariner User manual

Trace Engineering TS - User manual

Trace Engineering

Trace Engineering TS - User manual

Trace Engineering PS Series User manual

Trace Engineering

Trace Engineering PS Series User manual

Trace Engineering TS - User manual

Trace Engineering

Trace Engineering TS - User manual

Trace Engineering LEGEND II User manual

Trace Engineering

Trace Engineering LEGEND II User manual

Trace Engineering ST1000 Setup guide

Trace Engineering

Trace Engineering ST1000 Setup guide

Trace Engineering SW II - REV 4.01 User manual

Trace Engineering

Trace Engineering SW II - REV 4.01 User manual

Trace Engineering UX User manual

Trace Engineering

Trace Engineering UX User manual

Trace Engineering POWER MODULE SYSTEM User manual

Trace Engineering

Trace Engineering POWER MODULE SYSTEM User manual

Trace Engineering MICROSINE User manual

Trace Engineering

Trace Engineering MICROSINE User manual

Trace Engineering LEGEND I Owner's manual

Trace Engineering

Trace Engineering LEGEND I Owner's manual

Trace Engineering Mariner User manual

Trace Engineering

Trace Engineering Mariner User manual

Popular Inverter manuals by other brands

Briggs & Stratton 10000 Watt Operator's manual

Briggs & Stratton

Briggs & Stratton 10000 Watt Operator's manual

Siemens micromaster 410 operating instructions

Siemens

Siemens micromaster 410 operating instructions

DUALSUN FLASH Installation, operation and maintenance instructions

DUALSUN

DUALSUN FLASH Installation, operation and maintenance instructions

Pentair CD-15G Installation and user guide

Pentair

Pentair CD-15G Installation and user guide

Victron energy Phoenix 12/225 user manual

Victron energy

Victron energy Phoenix 12/225 user manual

SOLIS S5 Series user manual

SOLIS

SOLIS S5 Series user manual

Goodwe SBP SERIES user manual

Goodwe

Goodwe SBP SERIES user manual

Dometic TEC 40D Operation operating manual

Dometic

Dometic TEC 40D Operation operating manual

Sunways REVO-II Series user manual

Sunways

Sunways REVO-II Series user manual

DUROMAX XP10000E-06052018 user manual

DUROMAX

DUROMAX XP10000E-06052018 user manual

Saftronics FP5/GP5 Series Technical manual

Saftronics

Saftronics FP5/GP5 Series Technical manual

Sunways NT 10000 user manual

Sunways

Sunways NT 10000 user manual

wattsonic 4.0KW-3P Series user manual

wattsonic

wattsonic 4.0KW-3P Series user manual

brennenstuhl SES P4033 V3 manual

brennenstuhl

brennenstuhl SES P4033 V3 manual

Clenergy PV-ezRack PostMount 4-A installation guide

Clenergy

Clenergy PV-ezRack PostMount 4-A installation guide

Pyle PINV5 owner's manual

Pyle

Pyle PINV5 owner's manual

Yiyuan Electric AP Series user manual

Yiyuan Electric

Yiyuan Electric AP Series user manual

Telwin Superior240 CE Troubleshooting and repair manual

Telwin

Telwin Superior240 CE Troubleshooting and repair manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.