INSTALLER'S
GUIDE
IMPORTANT —ThisDocumentiscustomerpropertyandistoremainwiththisunit.Pleasereturntoserviceinformation
packuponcompletionofwork.
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
18-AH14D10-2A-EN
Comfort Coil™ Door Kit
Model:
KIT06654
KIT06655
KIT06656
A. GENERAL
B. INSPECTION
Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Check to be sure all major com-
ponents are in the container. Any missing parts should
be reported to your supplier at once, and replaced with
authorized parts only.
Parts List:
C. INSTALLATION
The kits allow for retrot of an updated coil into an older
coil case. The updated coil has three tubing extensions
from the front panel of the coil case.Parts List:
1. Place the front panel of the coil case on a at sur-
face.
2. Align the template to the upper left corner of the
front panel. See Figure 1.
3. Peel the backing from the template material and
stick the template to the panel as aligned in Step #2.
NOTE: There are two templates for the KIT06656.
The second template (B) is aligned to the line on the
bottom of the rst template (A) and attached as previ-
ously stated.
4. Place the new panel section on top of the template.
5. Mark the screw holes on the coil front panel and
then place the new panel to the side.
6. Drill a pilot hole for each of the marked screw holes.
7. Cut along the edge of the template as marked with
metal shears (aviation snips).
These instructions should be used only by quali-
ed individuals. These individuals should be
specically trained and experienced in the installa-
tion of furnaces, related accessories, and comfort
conditioning components. Improper installation
can create a hazard which could result in property
damage, personal injury, or death.
These instructions do not cover all variations in sys-
tems or provide for every possible contingency. Further
information may be desired or particular problems arise
which are not covered suciently by these instructions.
Contact your local distributor or the manufacturer as
listed on the furnace nameplate.
s
WARNING
APPLICATION TABLE
MODEL CASE
HEIGHT MODELS USED ON
KIT06654 17.5 TXC018,24,25,31-C-A,B
CCB18,24,30,36-A-A,B,C
KIT06655 22.5
TXC030,035,036,037,042,043-C-A,B
TXC031-E/S-A,B
CCB36,42,48-A-A,B,C
KIT06656 30.0
TXC048,049,050,060,061-C-A,B
TXC036,037,054,065-E/S-A,B
CCB60-A-A,B,C
Item Description Qty.
1 Front Panel Section 1
2 Drill Screws
8
3 Grommets. 3
4Template
(KIT06656 requires 2 templates) 1 or 2
Figure 1