trentios PC15-BCB User manual

MOBILE AIR CONDITIONER
User Manual
PC15/20/26-BCB

1
VERY IMPORTANT
Please read this instruction guide before install and using your mini
portable type air conditioner unit.
This instruction manual is the universal-purpose version for the units
that you purchase, it might be slightly different from the ones
described in the manual, but it does not affect your proper
operations and usage.
CAUTION
1. " PLEASE MAKE SURE THE PRODUCT VENTILATES ALL THE TIME !”
Please make sure the inlet and outlet ventilation is not blocked at all times.
2. Operate this unit on a horizontal surface to avoid water leakage.
3. Do not operate this unit in an explosive or corrosiveatmosphere.
4. Operate this unit in an ambient of 17~32 degree centigrade when the unit is in the
cooling function.
5. Clean air filter periodically to enjoy the most efficient cooling.
6.When the unit is shut down, please wait at least 3.5 minutes before restarting
this is to prevent the compressor from being damaged.
7. This unit needs at least 10 Amps of electricity to have its compressor
operational. To avoidthe household electricity block out, please do not use
any extension cord for this unit.
8. This unit is for indoor cooling only.
9. When the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid hazard.
10.In order to dispose the appliance safely, please remove the batteries from the unit
before scrapping it.

2
11. The air-conditioner can be connected only to a supply with systemimpedance no
more than 0.219Ω.In case necessary, please consult your supply authority for
system impedance information.
12. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
13. Drain out the water befor moving the unit.
ATTENTION
For effective cooling function, please ensure that the
following steps are undertaken:
1) Extend the exhaust hose to a length of not more
than 400mm. The exhaust hose must be kept
paralleland must not be bent up or down.
2) Aminimum distance of 500 mm must be kept
between the filter side of the unit and wallor any
other obstacles.

3
PORTABLE AIR CONDITIONER
This Air Conditioner has been designed and manufactured to the
highest standards of modern engineering.
- Moves easily from room to room on easy glide castors
- No installation required-just plug into any household
power outlet.
-Dehumidified and filtered air cycle improve breathing
environments effectively.
-220-240 Volt 50Hz operation
-1.8 meter cord with plug
UNPACKING INSTRUCTIONS
1. Place the unit in the correct upright position before unpacking.
2. Cut the two packing straps.
3. Slide the carton in anupwards motion and it will release from the base.
4. Grip the carry handles located on either sides of the unit and carefully lift until it
slides out of the foambase.
5. Lift and lean the unit slightly to take out exhaust hose
from unit’s bottom as picture.
6. Install the exhaust hose on the unit before operating the
unit.
CONTENTS
1 /Airconditioner unit

4
NAME OF THE PARTS
1. Control knob
2. Cool air-outlet
3. Exhaust hose’s connector
4. Exhaust tube
5. Hot air-inlet
6. Downside drain hole
7. Remote control’s location
8. Hot air-outlet’s joint part
9. Hot air-outlet
10. Upside drain hole
11. Cool air-inlet

5
CONTROL PANEL & DESCRIPTION
OF FUNCTION
Starting the unit
1. Turn the control knob to the “OFF” position.
2. Plug the unit into anappropriate power supply.
3. Turn the control knob to “COOL”, the cooling light is on while the unit is in operation.
Turning off the unit
1. Turn the control knob to the “OFF” position and the power supply is cut off, the unit
stops operation.
a. Low Fan Speed: Turn the control knob to the “ ” position, the unit
operates at lowfan speed.
b. High Fan Speed: Turn the control switch to the “ ” position, the unit
operates at high fan speed.

6
c. HI Cool Speed: Turn the control switch to the “ ” position, the unit
operates at high cool speed.
d. Low Cool Speed: Turn the control switch to the “ ” position, the unit
operates at high cool speed.
e. FULL:When the water tank is full, the full light is on.
f. COOLING:When the unit operates at high cool or low cool, the cooling light is on.
Self Evaporative System.
Self evaporative system –no drip tray or hose required. Condensation is recycled
into the system creating increased cooling efficiency.
Excess moisture is evaporated on the condenser turning into steam this steam is then
pushed out the exhaust hose creating a cooler dryer room. Please make sure that the
rubber cap is stocked on drain hose, when the unit is running.
Inextreme humidity the water tank may full signaling the tank full alarm.
※When the water tank is full, the "FULL" light is on. To resume operation, please
unplug the unit before removing the rubber cap“②” of the drain hole to drain out the
water.After the drainage is completed, please plug the unit and restart it.

7
MAINTENANCE
PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING.
AIR FILTER
The air filter located on the left hand side of the unit can be removed
simply by pulling the frame up.
Clean the air filter with a vacuum cleaner ensuring all dust is removed.
CONDENSER/EVAPORATOR
Use a brush attachment with a vacuum cleaner.
CABINET
Wipe with a damp cloth and polish with a soft cloth.
To remove the air filter, please follows the arrow direction and pull the
filter lightly, and then take out the filter for cleaning.

8
POWER SUPPLY
(1) Confirm the correct power supply before use.
(2) Insert the plug into the outlet firmly.
(3) Do not disconnect the power plug by pulling on the cord.
PLACE FOR USE
(1) Because the machine distributes hot air, please don’t place or operate in a
narrow place.
(2) In case of dangerous leak, don’t work the machine in a humid place.
(3) Don’ t place the machine in a sunlit corner otherwise the unit might shut
down due to the overheat and the color of the machine may soon fade out.
HELPFUL HINTS
Please ensure the unit is not placed against objects which will obstruct air
intake e.g. furniture or curtains as this will affect its performance dramatically.

9
EXHAUST TUBE INSTALLATION
1. Follow the instruction of arrowhead ①to Install the Hot air-outlet’s joint part
2. Follow the arrowhead ②to circumrotate the exhaust hose, and then the exhaust
hose can be installed firmly on the unit.
3. Follow the arrowhead ○
3to circumrotate the exhaust hose, then the exhaust
hose can be loosen and take out from the unit

10
SPECIFICATIONS
Model No.
PC15-BCB
PC20-BCB
PC26-BCB
Power Source
220-240V~50Hz
Rated Power
(EN60335)
Cooling
650W
900W
1100W
Cooling Capacity
1500W
2000W
2600W
Moisture Removed
25 L/DAY
30 L/DAY
50 L/DAY
Refrigerant
R410A
Dimensions (mm)
300Wx455Dx630H
(CE) N 842/2006:
R410A is a kind of fluorinated greenhouse gases covered by
the Kyoto Protocol Its total global warming potential (GWP) is 2088
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible
hazards to the environment or human health fromuncontrolled waste
disposal, please recycle it to prove the sustainable reuse of material
resources. Please ask return and collection systems or contact the
retailer where the product was purchased to return your used device,
they can recycle products safely.
This manual suits for next models
2
Table of contents
Other trentios Air Conditioner manuals