Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: SU3000RTXL3UHV
SmartOnline 3kVA On-Line Double-Conversion UPS, 3U Rack/Tower, 208/240V NEMA outlets
Highlights
3000VA / 3kVA / 2400 watt on-line double-conversion 3U rack/tower UPS
208/240V +/-2% output at 50/60Hz
Expandable runtime, Hot-swappable battery modules
RS232 port; support for SNMP/WEB card options
Front panel status LEDs with detailed load and battery metering
NEMA L6-20P input; 6-15/20R & L6-20R outlets
Description
3000VA / 3kVA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor
with an installed depth of 20 inches (50.8cm). Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT3U (multi-pack
compatible) external battery packs. Full time sine wave 200/208/220/230/240V AC output with +/-2% voltage regulation. Online, double-conversion
Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered
AC output. Operates continuously without using battery power during brownouts to 130V and overvoltages to 275V. NEMA L6-20P input plug.
NEMA 6-15/20R & L6-20R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery
operation. Network management interfaces support simultaneous communications via DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port
offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. Supports simultaneous detailed monitoring of
equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete
cabling. Integrated two bank PDU switching supports load shedding and remote-reboot of connected equipment. Multi-stage metered current
monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. 4
post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rackmount accessories available. Field replaceable, hot
swappable internal batteries and external battery packs. Attractive all-black UPS design. $250,000 connected equipment insurance
Package Includes
SU3000RTXL3UHV Rack-Tower UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post rackmount enclosures/tower stands included
Warranty information
Instruction manual
Features
True on-line, double conversion UPS provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 160 and 275 (130 to 275 at loads under 70%), regulating output to selectable 200/208/220/230/240V +/-2%
3000VA/2400 watt power capacity with 8 total outlets (6 NEMA6-15/20R & 2 NEMAL6-20R)
Standard internal battery set provides 14 minutes runtime at half load
Expandable runtime with multiple external battery packs (part# BP72V15-2U limit 1/BP72V28-3U multi-pack compatible)
Innovative design makes unit adaptable for rackmount, tower, or stacking applications
Uses only 3 rack spaces (3U) in standard 19 inch rack
DB9 serial port for network interface; SNMP compatible
Slot for optional SNMP/web card (part# SNMPWEBCARD)
PowerAlert unattended shutdown software and 6 ft. network cable included
Compatible with Tripp Lite's Watchdog Service Monitoring/Reboot Software