3
FIELD UPGRADE INSTRUCTIONS
REQUIRED PARTS AND TOOLS
TOOLS REQUIRED 2 x #2 Phillips screwdriver (Stubby and standard)
7/16 open end wrench
Small needle nose pliers
ESD wrist strap with grounding cord
KIT 06200-00252 EMV ICM330 Card Reader Upgrade Kit for 9600 - US Only
Description Qty
Sankyo 330 EMV Card Reader 1
Sankyo ICM330 Card Reader Data Cable 1
8 inch Braid Ground Cable 2
#6 x 3/8 Phillips Drive Pan Plastite Mounting Screw 4
#8 x 32 - 3/8 Long Standoff 1
Threaded #8 - 32 Thread Snap-in Insert 1
#8 x 32 - 3/8 Long Screw 1
Sankyo EMV Installation
** IMPORTANT **
If the unit intended for upgrade has a Quad-Port Module
with one of the following part numbers, the module is NOT
compatible with the EMV upgrade and must be upgraded.
09600-02030
09600-01013
These boards do not have a +12v port available.