manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TrueFlame
  6. •
  7. Burner
  8. •
  9. TrueFlame TFSB2-NG User manual

TrueFlame TFSB2-NG User manual

1
030323
TrueFlame Gas Side & Power Burner User Manual
Models: Side Burner: TFSB2-NG; TFSB2-LP
Power Burner: TFPB-NG; TFPB-LP
Remove
ATTENTION:
INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH THE CONSUMER.
CONSUMER: PLEASE READ & RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE AND BEFORE INSTALLING OR OPERATING.
This appliance is designed as an “ATTENDED APPLIANCE”.
DO NOT leave this appliance burning when unattended.
2
WARNINGS
READ THIS MANUAL CAREFULLY AND COMPLETELY
BEFORE USING YOUR SIDE BURNER TO REDUCE THE
RISK OF:
Fire, burn hazard, personal injury or property damage,
improper installation or servicing electric shock.
THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read this manual thoroughly before installation, use, or
servicing of this product.
CODE AND SUPPLY REQUIREMENTS:
This Side Burner must be installed in accordance with local
codes and ordinances, or, in the absence of local codes,
with the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), or Natural Gas and Propane Storage and Handling
Installation Code (CSA-B149.1)
IF YOU SMELL GAS:
󰀨


from the Side Burner and immediately call your gas suppli-

EXPLOSION HAZARD:
DO NOT-
ble materials. Keep area clear and free from combustible



stored in the vicinity of this or any other appliance.
The outdoor cooking gas appliance and its dedicated
󰀨
piping system during pressure testing of that system at test

The outdoor cooking gas appliance must be isolated from
the gas supply piping system by closing its dedicated
󰀨
supply piping system at test pressures equal to or less than
.5 psi (3.5kPa).
WARNING
NEVER cover slots, holes, or passage in the oven bottom
or cover an entire grate with material such as aluminum foil.



CALIFORNIA PROPOSITION 65
WARNING
This product is designed to operate with one of the
following fuel sources: Liquid Propane or Natural Gas.
The fuel used to operate this product, and the products of
combustion of such fuel, can expose you to chemicals
including Benzene which is known to the State of California
to cause cancer, birth defects and other reproductive harm
and Carbon Monoxide which is known to the State of
California to cause birth defects or other reproductive harm.
(For more information go to: www.p65Warnings.ca.gov.)
This appliance is designed as an “ATTENDED
APPLIANCE”. DO NOT leave this appliance
burning when unattended.
3
030323
TABLE OF CONTENTS
To view on your phone, scan the QR
code on your smart phone’s camera app.
(For Android devices, use Google Lens.)
PART #: Side Burner: TFSB2-NG; TFSB2-LP
Power Burner: TFPB-NG; TFPB-LP
THANK YOU
Thank you for your purchase. We’d like to welcome
you to the TrueFlame family of luxury outdoor kitchen
products, and we look forward to being a part your
home for years to come. As a family business with
over 30 years of industry experience, we aim to deliver
exceptional quality and personal service.
Welcome to the TrueFlame family and we hope you
love your new Side Burner!
FOR YOUR RECORDS
Please record the following information and refer to it when
contacting TrueFlame or an authorized dealer. The serial
number is located on the rating plate. The rating plate is
located on the underneath side of the drip tray.
INSTALLER
Please leave this manual for the owner
Serial Number:
Serial Number located underneath Drip Tray
Model:
Date of Purchase:
Place of Purchase:
For warranty information and to register your Side Burner
visit, amddirect.com/register

Warnings 2 & 4
Before Using the Side Burner 5
Installation 6-7
Gas Requirements 8-10
Custom-Built Enclosures/Island 11
Operation & Maintenance Tips 12-14
Maintenance Tips/ Optional Accessories 14
Side & Power Burner Illustrations 15
Illustrated & Replacement Parts 16-17
Warranty 18
Notes 19
4
SAFETY AND INSTALLATION WARNINGS
• Please read all instructions before installation or operating your gas Side Burner to prevent injury and appliance dam-
age
•
• Do not touch hot surfaces.
• Never use dented, rusty or damaged propane cylinders. Never store additional or empty propane cylinders in the Side
Burner cabinet or in the vicinity of this or any other appliance
• Close supervision is necessary when this or any appliance is used near children. Keep children away from the Side
󰀨
• Children should never be left alone or unattended in an area where a Side Burner is located. Place your Side Burner
well away from areas where children play. Do not store items that may interest children in or around the Side Burner,
in the cart, or in the masonry enclosure
• Never move the Side Burner when hot. When in use, portions of the Side Burner are hot enough to cause severe
burns.
• Always maintain the required clearances from combustibles as detailed. The Side Burner is designed for outdoor use
only. Never use in a garage, building, shed, breezeway, or other enclosed area. Do not use this Side Burner under
any unprotected overhead combustible construction
•
trailers, boats or any other moving installation
•
liquids
• Storing your Side Burner: Store your Side Burner in a well-ventilated area. If stored indoors, detach and leave L.P.
cylinder outdoors in a well-ventilated area away from heat and away from where children may tamper with it
• Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Electrical cords should be
placed away from walkways to avoid tripping hazard
•

• If the Side Burner is installed by a professional installer or technician, be sure that he/she shows you where your gas
󰀨󰀨
check for gas leaks immediately. Check only with a soap and water solution. Never check for gas leaks with an open

• Do not twist the gas supply hose
•
wear, or the hose is cut, it must be replaced before using the Side Burner
• The use of accessories, regulators, or components not recommend by the appliance manufacturer may cause injuries
and will void warranty
• Never light the Side Burner while the lid is on. Be certain the burners are positioned and seated over the gas valves
and on the burner support
• Never lean over the cooking surface when lighting or operating the Side Burner
• Use proper cooking tools with wood handles and insulated oven mitts when operating the Side Burner
• Be sure the gas supplied to the Side Burner conforms to the model you purchased. A natural gas Side Burner requires
natural gas to operate; a liquid propane Side Burner requires liquid propane to operate
• Never connect the appliance to an unregulated gas supply line. Side Burners operated without a regulator are unsafe
and will not be serviced until installed properly and safely. Unsafe operation without a gas regulator will void the war-
ranty
• Side Burners operating with natural gas must be installed with the NG regulator supplied with the unit and set to 4.0”
of water column pressure
• Side Burners operating with Liquid Propane must be installed with an LP regulator and set to 11” of water column
pressure
WARNINGS
5
030323
CHECK FOR SHIPPING DAMAGED:
VISIBLE DAMAGE

carton, be sure the damage is noted on the bill of freight

delivery. File claim for damages immediately, regardless of

CONCEALED DAMAGES
If damages are unnoticed until the Side Burner is un-
packed, notify the transportation company or carrier

This should be done within (5) days of the delivery date. Be

assume
responsibility for damage or loss incurred in transit.
IMPORTANT NOTES:
BE MINDFUL OF WIND DIRECTION
Using your Side Burner in windy conditions may disrupt

for. If wind pushes the heat into the control panel, then the

Side Burner pulls air in through its front and vents hot gas-
es up through the grate. If the control panel or knobs are
󰀨
GAS LINE LENGTH
Keep all gas supply lines as short as possible. Gas lines
lose pressure over distance and with each elbow or “T”
󰀨
performance.
PROPER LEVELING
PROPER LEVELING DURING INSTALLATION IS
CRITICAL. A SIDE BURNER THAT IS OUT OF LEVEL
WILL CAUSE ERRATIC BURNER COMBUSTION AND
INEFFICIENT, UNEVEN HEATING. THE SIDE BURNER
SHOULD BE LEVEL IN ALL DIRECTIONS. ADJUST-

MOVING A FREESTANDING UNIT.
CONSTRUCTION ZONES
Keep all stainless steel products away from construction
zones. Construction debris such as (but not limited to)
stone dust, stucco, and lime dust could damage or
permanently discolor stainless steel products. Keep all
caustic chemicals including chlorine and pool cleaning
products away from stainless steel at all times.
BEFORE USING THE SIDE BURNER
UNPACKING YOUR SIDE BURNER
Included with your TrueFlame Side Burner are the following
loose items:
Cooking Grates: TFSB2(1), TFPB(2)
Drip Tray: TFSB2(1), TFPB(1)
Lid: TFSB2(1), TFPB(1)
Lid Handle: TFSB2(1), TFPB(1)
Manual: TFSB2(1), TFPB(1)
Transformer: TFSB2(1), TFPB(1)
Set of orices
•
included
•
included
• The drip tray will be at the bottom of the unit and will
slide into the drip tray support brackets.
6
INSTALLATION
N
on
-
C
o
m
b
usti
b
le
En
s
l
o
s
u
r
e
A
B
C
A
M
eta
l
S
t
u
d
s
Ventilation
Ventilation
Figure 1
Side Burner
MODEL A: WIDTH B: HEIGHT C: DEPTH
TFSB2  
TFPB 14”  18 3/4”
Side Burner
MODEL A: WIDTH B: HEIGHT C: DEPTH
TFSB2  
TFPB   
ISLAND CUT OUT DIMENSIONS
OVERALL PRODUCT DIMENSIONS
ALL BBQ ISLANDS MUST BE MANUFACTURED
FROM “NON COMBUSTIBLE” MATERIALS.
TrueFlame Side Burners are a “built-in” gas unit that re-
quires a non-combustible island/enclosure. Use Figure 1
and Table 1 as a guide.
It is recommended to use cement board with steel studs
and proper ventilation per local codes. A minimum 4-inch
vent size is required, one at the top and one at the

during operation of the Side Burner.
Table 1
Table 2
The Side Burner must have a minimum of 14” clearance
from the right side, left side and rear (back) of the Side
Burner from a protected combustible wall. Refer to Figure
3.
IMPORTANT NOTE:
Clearance from the Side Burner and a non-combustible
wall
(i.e. brick wall, see Figure. 2). The Side Burner requires a
minimum of 4” clearance from the right side, left side and
rear (back) of the Side Burner from any non-combustible
wall. This allows for proper ventilation and helps prevent
dangerous overheating.

minimum of a 4” clearance from the rear of the Side Burner
(to allow for proper ventilation and help prevent dangerous
overheating. Clearance Figure 2).
MINIMUM SIDE BURNER CLEARANCES:
Minimum clearances between the Side Burner and any
side wall or rear wall must fall within one (or more) of the
following:
Min. 4”
Non-Combustible Wall
Open Hood
Side View Grill Body
Non-Combustible
Backsplash
Figure 2 *Shown with grill*
IMPORTANT NOTE:

any non-combustible walls beginning behind it.
Note: Refer to page 10 for Custom Built-In Enclosures/
Islands when building.
7
030323
Clearance from the Side Burner and protected combus-
tible wall (i.e. A non-combustible wall in front of a combus-
tible wall to serve as a barrier. This can be accomplished by
-
strate. See Figure 3). The Side Burner must have a mini-
mum of 14” right, left and rear clearance from the protected
combustible wall. ( 4” non-combustible material clearance,
plus an additional 10” clearance between the Side Burner
and protected wall.)
INSTALLATION
Min. 14”
Non-Combustible Brick
Open Hood
Side View Grill Body
Non-Combustible
Substrate
Min. 4”
Combustible Wall
Figure 3 *Shown with grill*
Clearance from the Side Burner and combustible wall
(Clearance Figure 4). The Side Burner must have a mini-
mum clearance of 18” from the right side, left side and rear
of the Side Burner to any combustible wall.
Min. 18
”
Combustible Wall
Open Hood
Side View Grill Body
Combustible
Back Wall
Figure 4 *Shown with grill*
OVERHEAD CONSTRUCTION AND EXHAUST HOOD
REQUIREMENTS
This Side Burner is designed for outdoor use only.
DO NOT use this Side Burner inside a building, garage, or
enclosed area.
DO NOT use this Side Burner in or on a recreational vehi-
cle or boat.
When installing this Side Burner in a combustible surround,
an TrueFlame insulating jacket/Side Burner liner must be
used.

countertop and the overhead construction.
When the Side Burner is installed under a combustible
overhead construction, the area above the cooking sur-
face of the Side Burner must be used with an exhaust
hood.
combustible overhead construction. See Figure 5.
IMPORTANT NOTE:
• DO NOT use this appliance under unprotected
combustible overhead construction.
• When installed under overhead non-combustible

NONCOMBUSTIBLE WALL
OVER HEAD CONSTRUCTION
EXHAUST
HOOD
Min.
5’
Figure 5 *Shown with grill*
When using an exhaust hood, the area
above the cooking surface of the Side
Burner must be covered with a hood
larger than the cooking area of the Side
Burner, AND the blower must produce
a minimum of 1200 CFM (cubic feet per
minute) for proper exhausting outdoors.
8
GAS REQUIREMENTS
GAS LINES
Never connect a gas line directly to the Side
Burner. A pressure regulator must be installed
on all gas equipment. Removing or failing to

and serious personal injury and will void the
warranty
WARNING
Ensure the gas supplied meets the minimum pressure
requirements. See Table 3 for gas requirements measure in
Water Column (W.C.) pressure.
GAS PRESSURE REQUIREMENTS
Pressure Natural Gas Propane Gas
Min. Inlet 4.0” WC (1.00.kPa) 10.0” WC (2.49 kPa)
 7.0” WC (1.74 kPa) 14.0” WC (3.48 kPa)
Table 3
IMPORTANT:
All electrical outlets in the vicinity of the Side
Burner must be properly grounded in accor-
dance with local codes, or in the absence of
local codes, with the National Electrical Code,
ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1, whichever is applicable.
Keep all electrical supply cords and fuel supply
hoses away from any heated surface.
NOTE:

󰀨
kit. Conversion kits are included with this Side Burner and
located with the manual. Converting gases may require
additional parts not included with this Side Burner. (See
Gas Conversion section for details).
NATURAL GAS REQUIREMENTS
•-
als perform the required plumbing on this product.
• Check the Rating Plate to make sure the gas
supply you are hooking up to is the gas type the Side
Burner is manufactured for.
• To ensure satisfactory performance, the gas supply
line must be sized to accommodate the total BTU

connected to that line.
• In no case should pipe less than 1/2” inside diameter
or 1” outside diameter ever be used to connect this
product.
NOTE: DO NOT use any tape, pipe dope or threading

in the regulator and prevent your Side Burner from
functioning properly.
CONNECTING TO THE NG REGULATOR
Figure 6
9
030323
Figure 7
GAS REQUIREMENTS
SAFE USE AND MAINTENANCE OF PROPANE GAS CYLINDERS
IMPORTANT FOR YOUR SAFETY
READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE GAS CYLINDER.
When operating a Propane gas cylinder, these instructions and warnings MUST be observed.
FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION
CYLINDER/CONNECTOR REQUIREMENTS
a. Propane gas cylinders, valves and hoses must be
maintained in good condition and inspected before
each use of an appliance. They must be replaced if
there is any visible damage. If the hose is cut or shows

before using the appliance. (See section e.)
b. This unit, when used with a cylinder, should be
connected to a standard 5-gallon (20 lb.) propane gas

device.
c. 
(30.5cm) in diameter and 18” (45.7cm) high. Cylin-
ders must be constructed and marked in accordance
with the U.S. Department of Transportation (D.O.T.)

for Cylinders, Spheres, and Tubes for Transportation of
Dangerous Goods and Commission, CAN/CSA-B339,
as applicable.
d. The cylinder used must include a collar to protect the
cylinder valve, and the cylinder supply system must be
arranged for vapor withdrawal.
e. The pressure regulator and hose assembly used must

1.6 (See Figure 7)
f. The propane gas cylinder valve must be equipped with
a cylinder connection device, described as Type I in the

is commonly describes as an Acme thread coupler.
g. If the propane gas cylinder comes with a dust cap,
place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use.
COUPLER OPERATION
To connect the regulator/hose to the Propane gas
cylinder valve tting:
Press the hand nut on the regulator over the Acme thread

to engage the threads and tighten until snug. The pliers of
a wrench should not be necessary. Only cylinder marked
“Propane” may be used.
To Disconnect:
Turn the hand nut counterclockwise until detached. See
Figure 7.
IMPORTANT: Before using the unit, and after each time
the cylinder is removed and reattached check the hose for
wear (See section “a”) and check all connections for leaks.
Turn OFF the unit valves and open the main cylinder valve,
then check connections with soapy water. Repair any leaks
before lighting the unit.
CAUTION: Always turn the Propane cylinder main valve
OFF after each use, and before moving the unit and
cylinder or disconnecting the coupling. This valve must
remain closed and the cylinder disconnected while the

by a safety feature when the coupler is disconnected.
Carefully inspect the hose assembly each time before
the gas is turned ON. A cracked or frayed hose must be
replaced immediately.
If the appliance is stored indoors, the cylinder must be
disconnected and removed. Disconnected cylinders must
be stored outdoors, out of reach of children, with threaded
valve plugs tightly installed, and must not be stored in a
building, garage, or any other enclosed area.
FOR YOUR SAFETY
• DO NOT store a spare Propane gas cylinder under of
near this appliance.
•
• IF THE INFORMATION IN SECTIONS “a” AND “b”


For proper ventilation and enclosure requirements,
see the Enclosure Installation and Ventilation
Requirements on pages 6 and 10.
10
PROPANE GAS TANK REQUIREMENTS
FILLING AND REFILLING LP GAS CYLINDERS
All purging and relling of LP gas cylinders must be
performed by qualied personnel in the LP gas
industry. Never store a spare LP gas cylinder under or
near this appliance.
Never ll the LP gas cylinder beyond 80 percent full.
Failure to follow these instructions may result in
explosion, personal injury or death.
LP gas Side Burner models are designed for use with a
standard 20 lb. liquid propane gas (LP) tank with type (1)
valve connections. (Not included)
A dented or rusty LP tank may be hazardous and should be
avoided. If in doubt, have it checked by your LP supplier.
Always check for leaks after every LP tank change. (See
Checking For Leaks)
LP Tanks must be stored outdoors in a well-ventilated area
out of the reach of children. If your Side Burner is stored
indoors, the LP tank must be stored outside, in upright posi-

IMPORTANT:
All installation and all installation parts must conform to
local codes with the National Electrical Code,
ANSI Z223.1/ NFPA 70 latest edition and the National
Fuel Gas Code ANSI Z223.1/NFPA 54 in the U.S. and
CGA-B149.1/.2 in Canada
CONNECTING TO A SIDE BURNER

connection to connect a single gas line to both a grill and
a Side Burner. We recommend a licensed gas technician
install all gas lines. See below Figure 8 for

From Side Burner
To Propane Tank or
Natural Gas Connection
3/8” Fittings
From Grill
To grill, located underneath
and behind grill
To side burner, located underneath
and behind burner
3/8” threaded “T” adapter
LIQUID PROPANE INSTALLATION
IMPORTANT:
Ventilation is require in the enclosure on opposite sides
to create cross-ventilation. Liquid propane is heavier than
natural gas and vents should be located near the bottom of
the enclosure.
TESTING FOR LEAKS
Create a soapy water solution of 1 part soap and 3 parts
󰀨
Turn on the fuel supply.
For Natural Gas, turn the valve handle ¼ turn to align with

clockwise one full rotation. Apply the soap solution
generously by paint brush or squirt bottle on all connections


󰀨
and dry. Tighten the loose joint or replace the faulty part
with manufacturer-recommended replacement parts.
DO NOT attempt to repair the L.P. cylinder valve if it is
damaged. The only way to safely resolve a damaged
cylinder is to replace it by calling an authorized gas
appliance service technician or an LP gas dealer. Repeat
the leak test to ensure that no leaks are present. Do not
use the appliance until the leak is corrected.
GAS REQUIREMENTS
11
030323
CUSTOM-BUILT ENCLOSURES/ ISLANDS
VENTILATION REQUIREMENTS
FOR ALL ENCLOSURES
FOR ALL GAS TYPES:
Natural Gas, Household Propane or LP Cylinder/Tanks
FOR YOUR SAFETY, you must provide the openings
listed below for replacement air and ventilation of the
Side Burner enclosure (i.e. in case of possible gas
leaks from connections or LP tanks/cylinders). Failure
to do so may result in a re or explosion causing prop-
erty damage, bodily injury or death.
One side of the enclosure shall be kept completely
open to the outside OR four (4) minimum ventilation
openings MUST be provided:
• Each opening must have a minimum of 10 sq. in. of
free area. The openings must be equally sized, provid-
ing a total of 40 sq. in.
• Two openings must be in the side walls of the
enclosure, at the top and spaced a minimum of 90º
from each other. The openings must begin 1” or less
below the countertop edge and end no more than 5”
below the countertop edge. See Figure 9.
• Two openings must be in the side walls of the

minimum of 90º from each other. The openings must


• The openings must remain unobstructed:
The clearance between the openings and any items
outside of the enclosure is a minimum of 6”. The
clearance between the openings and any items withing
the enclosure is a minimum of 2”. This provides free

island cool during operation of the Side Burner. See
Figure 9.
IMPORTANT:
Ventilation is require in the enclosure on opposite sides
to create cross-ventilation. Liquid propane is heavier than
natural gas and vents should be located near the bottom of
the enclosure.
Min. 90˚
1” Min.
5” Max.
Min. (4) Openings
10 sq.in. of free
area min. (each)
Total= 40 sq. in.
Countertop
Ventilation Requirements
• Minimum 4 openings (2 per side wall
spaced at 90°)
• Top openings: within 5” of countertop
• Bottom openings: within 5” of floor
• Each vent opening: Min. 10 sq. in of
free area (Total to = 40 sq. in.)
Vent openings must be kept
clear and free at all times.
5” Max.
1” Min.
Enclosure Side View
Vent Opening
2” Min.
6” Min.
• 6” Minimum clearance in front of all
vent openings to any items outside
the enclosure
• 2“ Minimum clearance in front of all
vent openings to any items inside
the enclosure
UNOBSTRUCTED VENT OPENINGS
VENTILATION REQUIREMENTS
Figure 9
Figure 10
12
OPERATION & MAINTENANCE TIPS
READ INSTRUCTIONS
BEFORE LIGHTING
SPARK IGNITION
CAUTION: Keep your face and body away from
the Side Burner top when lighting
Always remove the stainless steel lid before light-
ing; do not attempt to ignite burners while the lid
is on.
Make sure gas supply is turned ON.
Make sure burner control knobs are in the “OFF”
position. DO NOT turn on more than one valve at
a time for initial ignition.
1. Press in the control knob then slightly turn
the knob counterclockwise while still pressing
inward.
2. Hold in the above position for 5 seconds
allowing the gas to reach the manifold.
3. Turn the knob counterclockwise past the

hear the one time clicking sound of the spark
ignition.
4. If ignition does not occur in 5 seconds, turn
the burner control OFF, wait 5 minutes, and
repeat the lighting procedure.
5. After ignition, set the knob to the desired
setting.
1. Place either a burning long-barrel butane
lighter or a burning long-stem match near


against the surface of the back burner.
2. 


appropriate control knob and while pressing
turn it counterclockwise to the HI position.
Remove the lighter or match when the burner
lights and release the control knob.
3. If ignition does not occur in 5 seconds, turn
the burner control OFF, wait 5 minutes, and
repeat the lighting procedure.
4. After ignition, set the knob to the desired
setting.
MANUAL (MATCH LIGHT) IGNITION
READ INSTRUCTIONS
BEFORE LIGHTING
CAUTION: Keep your face and body away from
the Side Burner top when lighting
Always remove the stainless steel lid before light-
ing; do not attempt to ignite burners while the lid
is on.
Make sure gas supply is turned ON.
Make sure burner control knobs are in the “OFF”
position. DO NOT turn on more than one valve at
a time for initial ignition.
SHUT OFF INSTRUCTIONS
1. To shut OFF the Side Burner, depress each valve control knob and
while pressing turn clockwise to the “OFF” position.
2. Always close the valve from the gas supply after each use of the
Side Burner.
This appliance is designed as an “ATTENDED APPLIANCE”.
DO NOT leave this appliance burning when unattended.
13
030323
OPERATION & MAINTENANCE TIPS
SHUT OFF INSTRUCTIONS
1. 󰀨
and while pressing turn clockwise to the “OFF” position.
2. Always close the valve from the gas supply after each
use of the unit.
NOTE:
When using a portable Propane tank: Propane tanks are
equipped with a safety shutdown device that may cause


ADJUSTING YOUR BURNER TO A LOWER SETTING
• Make sure the Side Burner is cool.
•
adjusting the burners.
• Light the burner.
• Turn the burner to “LOW”.
•󰀨
•

MAINTENANCE TIPS
Stainless steels need to be cleaned for aesthetic
considerations and to preserve corrosion resistance.
Stainless steel is protected from corrosion by a thin layer of

with the chromium in the stainless steel to form this passive

SIDE BURNER EXTERIOR


SIDE BURNER INTERIOR
•󰀨
minutes after cooking.
• Use an approved stainless-steel oven cleaner to
remove grease build up.
• Routinely have a professional barbecue cleaning
company detail the Side Burner for best results and
longevity.
STAINLESS STEEL MAINTENANCE

remove grease and splatters. Use a commercially available
-
faces. Doing these things on a regular basis minimizes the
󰀨
When removing stubborn stains:
• Do not use metallic abrasives and always rub in the
direction of the grain.
• Some household cleaning products are not suitable for
stainless steel; be sure to read the label before using
on the Side Burner.
•-
bing in the direction of the grain.
• Specks of grease may gather in the grain of the
stainless steel and bake on to the surface, giving the
appearance of rust.
•
grit non-metallic abrasive pad (Scotch Brite is good) in
conjunction with a stainless steel cleaner.
• Solutions used for cleaning concrete and masonry can

• Be sure your TrueFlame products are well protected
before using these products.
POWER FRONT PANEL LED

prong connection) into the transformer. Plug the transform-
er into an electrical outlet rated for the transformer.
Any contamination of the surface by dirt, or other
material, hinders this passivation process and traps
corrosive agents reducing corrosion protection. Thus,
routine cleaning is necessary to preserve the
appearance and integrity of the surface.
14
IMPORTANT NOTE: FOR LOCATIONS NEAR COASTAL AREAS AND POOLS:
#304 stainless steel materials used in the construction of your TrueFlame Side Burner are highly rust
resistant, however, chlorine in the air from swimming pools or the salt from sea air may cause surface
rust to appear and even create some pitting if left on the product. Here are a few tips to avoid this if

•
• Allow the surfaces to dry before installing the cover. Do not cover a damp Side Burner.
•
Side Burner.
• For seasonal storage use the product referred to above, ensure the Side Burner is dry, then cover
and secure the cover to minimize the amount of damp air getting to the surfaces.
OPERATION & MAINTENANCE TIPS
󰀨
󰀨󰀨-
ent stainless; steel cleaners available.
15
030323
POWER BURNER: TFPB
SIDE & POWER BURNER ILLUSTRATIONS
SIDE BURNER: TFSB2
16
ILLUSTRATED & REPLACEMENT PARTS
TFSB2
Double Side Burner
17
030323
ILLUSTRATED & REPLACEMENT PARTS
TFPB
Power Burner
18
WARRANTY
GOLD STANDARD
LIFETIME
WARRANTY
GOLD STANDARD
WARRANTY
AMD DIRECT GAS APPLIANCES
(GRILLS, SIDE/POWER BURNERS,
GAS GRIDDLE & OVEN)
Your investment in AMD Direct products is backed
by the strongest warranty in the industry. In
addition to precision engineering and outstanding
performance, AMD Direct products include our
GOLD STANDARD LIFETIME WARRANTY with all
replacement parts 100% non-prorated. Eective
with purchases as of 8/1/21.
• Gold Standard Lifetime Warranty on construction and manufacturer defects
• Gold Standard Lifetime Warranty on Stainless Steel Construction
• Gold Standard Lifetime Warranty on Cooking Grates, Burners, Burner
Covers, Valves, Flame Tamers, and Heatzone Separators, Temperature
Gauges, & Hood Springs
• Gold Standard Lifetime Warranty on Briquette Systems
• 3 YEAR Warranty on all other Parts, Components, & Electrical, including:
LED Bulbs, Wire Harness, & Switches; Power Source Wire; Transformer;
Interior Halogen Light Wire & Bulb
DRAWERS, DOORS, GRILL LINERS, & CARTS
• Gold Standard Lifetime Warranty on Construction,
Workmanship and Materials for all Stainless Steel parts,
Including Doors, Drawers, Grill Liners, & Carts
• 3 Year Warranty on Electrical (Warming Drawers)
COVERS
• Gold Standard Lifetime Warranty on Covers, including Grills,
Carts, Side/Power Burners, Gas Griddle & Oven
COMMERCIAL APPLICATIONS
GAS GRILLS
• Gold Standard Lifetime Warranty on Workmanship, Construction,
& manufacturer defects for all commercial and/or hospitality
applications
• Warranty is void upon misuse, including lack of regular cleaning,
vandalism, or theft
• Warranty is valid only if regular maintenance is exercised. Due to
the nature of commercial applications (multiple users, lack of
control of use, etc.) regular maintenance is mandatory
VER 2.21.23
VENT HOODS, REFRIGERATION,
COLD STORAGE & SINKS
VENT HOODS
• 5 Year Warranty on all Stainless Steel Construction
• 3 Year Warranty on Blowers, LED Lighting, Wiring Harness and Switches
15" & 24" REFRIGERATION MODELS
• 3 Year Warranty on all construction including Compressors
• 1 Year Warranty on Transformer, LED Bulbs, LED Harness, Power Source
Wire, LED Switches, Interior Halogen Light Wire/Bulbs
21" REFRIGERATION MODELS
• 1 Year Warranty on all Construction & Electrical components including
Compressor, Transformer, LED Bulbs, LED Harness, Power Source Wire,
LED Switches, Interior Halogen Light Wire/Bulbs
COLD STORAGE & SINKS
• Gold Standard Lifetime Warranty on Ice Chest
• Gold Standard Lifetime Warranty on Drains & Faucets
AMD Direct Warranty is valid for original purchaser
at original site of delivery with proof of purchase
and photo documentation only. Registration form
must be submitted online within 30 days of the
purchase date to validate the warranty. Warranty is
void upon transfer of ownership. Warranty does not
apply to products installed in any commercial,
rental, or nonresidential application (exception of
the Resort Grill, Alturi, & TRL). Warranty covers
replacement parts only. Manufacturer is not
responsible for labor or labor-related costs.
Warranty does not cover discoloration, surface rust,
corrosion, or oxidation, which may occur due to
harsh environments, chemicals, or overheating.
Warranty will not apply for damage resulting from
improper installations, abuse, extreme
environments, grease fires, or misuse. Proof of
regular and proper maintenance is required.
Coastal, humid, and/or salt environments are
subject to manufacturer review. All out-of-box
claims must be made within 30 days of purchase
and must be made prior to installation. Any product
installed damaged will be considered damaged
during installation and not covered under warranty.
Warranty and registration forms are available at
www.amddirect.com/register. Please be advised -
all display models are sold “as is” and the warranty
covers the following items only: main burners (Gold
Standard Lifetime Warranty), grates (Gold Standard
Lifetime Warranty), burner covers (Gold Standard
Lifetime Warranty). All warranties are subject to the
review and approval of the manufacturer.
14520 DELTA LANE SUITE 105,
HUNTINGTON BEACH, CA 92647
800.966.8126
AMDDIRECT.COM
19
030323
NOTES
20
030323
For more information call
Customer Care at 800-966-8126
Hours: 7am - 5pm PST
14520 DELTA LANE SUITE 105
HUNTINGTON BEACH, CA 92647
800.966.8126
VER 2.21.23

This manual suits for next models

3

Popular Burner manuals by other brands

baltur TBG 80 LX PN V Manual user instructions

baltur

baltur TBG 80 LX PN V Manual user instructions

Riello DB 4 SE FGR Installation, use and maintenance instructions

Riello

Riello DB 4 SE FGR Installation, use and maintenance instructions

Megatherm MPB 90 Pro Installation & user manual

Megatherm

Megatherm MPB 90 Pro Installation & user manual

IKEA MOJLIG manual

IKEA

IKEA MOJLIG manual

Ecoflam MAX GAS 350 P manual

Ecoflam

Ecoflam MAX GAS 350 P manual

Riello RRS 68/E O2 BLU Installation, use and maintenance instructions

Riello

Riello RRS 68/E O2 BLU Installation, use and maintenance instructions

Riello 40 BIO Installation, use and maintenance instructions

Riello

Riello 40 BIO Installation, use and maintenance instructions

Ecoflam BLU 500.1 PR manual

Ecoflam

Ecoflam BLU 500.1 PR manual

Napoleon B35NTL Installation and operating instructions

Napoleon

Napoleon B35NTL Installation and operating instructions

baltur TBG 800 MC Instruction manual for installation, use and maintenance

baltur

baltur TBG 800 MC Instruction manual for installation, use and maintenance

Riello 40 Series Installation, use and maintenance instructions

Riello

Riello 40 Series Installation, use and maintenance instructions

Viessmann VITOSOL 200 Service instructions

Viessmann

Viessmann VITOSOL 200 Service instructions

Riello Bio RLS 68/M Installation, use and maintenance instructions

Riello

Riello Bio RLS 68/M Installation, use and maintenance instructions

Ecoflam MAX GAS 350 PAB TC manual

Ecoflam

Ecoflam MAX GAS 350 PAB TC manual

Riello F5 Installation, use and maintenance instructions

Riello

Riello F5 Installation, use and maintenance instructions

Enertech Nu-Way MG1190-LN T3D Installation & maintenance manual

Enertech

Enertech Nu-Way MG1190-LN T3D Installation & maintenance manual

WLD-TEC Flame 100 instruction manual

WLD-TEC

WLD-TEC Flame 100 instruction manual

baltur GI 1000 DSPN-D Instructions for use

baltur

baltur GI 1000 DSPN-D Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.