Cables Connection between damper motors and C210 controller.
The damper motor connects direct to the controller with RJ45 type cable,
10 Feet (3 M) long. Be careful to enter the plug into the socket at the motor and
the C210 controller side till the end, to enable good electrical connection.
It is NOT allowed to extend this cable.
Dry Contact = Air Condition Connection = BMS
The BMS output is a Dry contacts one.
Connect it to the air condition control system to allow the A/C operation.
When first damper opens, A/C should start operation.
When last damper closes A/C should turn OFF.
Find at the A/C control box the input to allow BMS operation and select
between N.O. or N.C. outputs according the A/C control operation.
Bypass connection
The Bypass motor connects direct to the C210 controller to the plug marked
B.P (Bypass).
Use RJ11-4 cable between the C210 Controller and the Bypass damper
motor.
General instructions:
Follow the local electrical installation codes and regulations.
Warning!
Do not extend any cables in the system.
System must be installed per the instruction in this document.
In case system elements will be used not according to the instruction written
in this document, warranty will be not valid.
Unprofessional installation and/or damage to the system elements will cancel
any warranty.
No field repair allowed to any of the system elements.
System elements repair are not allowed.
Repair done by unauthorized personal will cancel warranty.
Operating from line power which is not standard and approved by the power
company, such as operation from generator or building that was not connected
by the power company will cancel warranty.
Thermostat Location Consideration
• The thermostat should be mounted no more then 100 Feet (30 M) from the
C210 Controller.
• It is recommended to mount the thermostat were room temperature is
normal.
• Do not mount the thermostat at outside wall and not at hot air drift
locations.