UFO IP-01 Specification sheet

PRODUCT USER GUIDE
IP-01 Weatherproof Enclosure
PLEASE READ THIS USER GUIDE BEFORE INSTALLING, OPERATING
OR PERFORMING MAINTENANCE ON THE ENCLOSURE.
Rev: C1

INTRODUCTION
IP-01 WEATHERPROOF ENCLOSURE USER GUIDE
2
Thank you for purchasing this UFO weatherproof enclosure which is fitted with an LED light
source unit.
To ensure the enclosure is mounted and connected correctly please read this user guide before
installing and operating or performing any maintenance on the enclosure. To ensure that the
light source within the enclosure is set up optimally and gives a long service life, please read the
light source user guide supplied with the enclosure before installing operating or performing
any maintenance on the unit.
Please keep both these guides for future reference.
This user guide is laid out in 3 sections:
Introduction - information on the enclosure and its light source.
Installation - details on how to install and power up the enclosure
(supplements the light source guide).
Maintenance - maintenance log, troubleshooting guide, technical specification.
IMPORTANT
This product must be installed in accordance with the applicable installation code, by a person
familiar with the construction and operation of the product, and the hazards involved. When
used in the USA or Canada, cables connected to this enclosure must be UL listed and not only
suitable for functional purposes but also for the environment/location in which the enclosure is
installed.
Type Y Attachment: If the external flexible cable or cord of this luminaire or associated
PSU/driver is damaged, it shall be exclusively replaced by the manufacturer or his service agent
or a similar qualified person to avoid a hazard.
Location: This enclosure must be located out of direct sunlight and away from areas prone to
flooding.
Circulation: It is imperative that a gap of at least 300mm is le around the unit and it is located
away from any other heat source. This is to allow air to circulate and prevent overheating. The
location must have free ventilation and must not have an ambient temperature higher than
that specified for the unit.
Mounting: This enclosure should be fixed upright to a vertical surface only, with suicient gap
at the front to allow the enclosure lid to be opened the full 130° for internal access.
Seal Integrity: Always close and secure the enclosure door aer access.

MODEL VARIATIONS
The UFO IP-01 enclosure is available in two power source variants:
1. DC supply (12V DC) denoted by the model number having the suix DC. This version has the
light source 12V DC PSU mounted remotely external to the enclosure and the unit is powered
from the DC supply to a terminal block inside the enclosure. For this version, the PSU can be
supplied by UFO or the customer. For the USA and Canada, if supplied by the customer the PSU
must be UL listed and not only suitable in terms of correct voltage and wattage but also suitable
for the environment/location in which the PSU is to be installed. (See figure 1 below.
2. Mains supply (240V 50Hz) denoted by the model number having the suix AC. This version
has the light source 12V DC PSU mounted inside the enclosure and the unit is powered from a
mains supply to a fused terminal block inside the enclosure. (See figure 2 on next page).
INTRODUCTION
3
UFO LIGHTING
FIGURE 1- DC POWERED VARIANT

INTRODUCTION
4
FIGURE 2- AC POWERED VARIANT
IP-01 WEATHERPROOF ENCLOSURE USER GUIDE

MODEL INFORMATION
INTRODUCTION
5
UFO LIGHTING
Ordering Code Light Source Model Power Variant Max Waage
UFO IP01MIC1000AC MicroLED 1000 240VAC 50Hz 5W
UFO IP01MIC1000DC MicroLED 1000 12V DC 5W
UFO IP01MIC4000AC MicroLED 4000 240VAC 50Hz 5W
UFO IP01MIC4000DC MicroLED 4000 12V DC 5W
DIMENSIONS
Note that dimensions are shown in mm.

MOUNTING THE ENCLOSURE
INSTALLATION
6
The IP55 certification of these weatherproof enclosures is only valid if the enclosure is
wall mounted in the orientation detailed below.
The enclosure must be located out of direct sunlight and there must be a minimum of
300mm (12”) of space around all sides to allow for air circulation and to prevent
overheating.
Mounting the enclosure in any other way will invalidate the IP rating and the product
warranty.
UFO will accept no responsibility for any loss or damage that occurs due to incorrect
mounting.
IP-01 WEATHERPROOF ENCLOSURE USER GUIDE

INSTALLATION
7
UFO LIGHTING
MOUNTING THE ENCLOSURE
The diagram below shows the mounting hole positions on the rear face of the enclosure.
Mount as follows:
1. Support the enclosure against the mounting surface and use a spirit level to ensure
that it is level. As detailed opposite, the glands must be facing downwards.
2. Mark the 4 mounting hole positions and remove the enclosure from the surface.
3. Choose appropriate fixings for the surface that the enclosure is being mounted to. Note
that unless UFO are installing the unit then we do not supply fixings. This is due to the
large variance of surface types the enclosure may be mounted to.
4. Follow the instructions for the chosen fixings and use them to secure the enclosure to
the mounting surface.
Outside/Rear
of enclosure
MOUNTING THE REMOTE PSU
For remote DC enclosures (suix
DC) the remote PSU should be
mounted in a suitable location
considering the following to
minimise voltage drop between
PSU and enclosure:
1. Distance between PSU and
enclosure.
2. Size (AWG) of interconnecting DC
cable between PSU and enclosure.
NOTE: Maximum distance of 10m of
interconnecting cable based on a
minimum cable size of 16AWG.

INSTALLATION
8
CONNECTION - FOR DIRECT MAINS OPERATION (AC SUFFIX MODELS)
There may up to three connections required via the appropriate gland:
1. The fibre harness.
2. The DMX cables for the MicroLED 4000 when configured as Master/Slave
3. Mains supply cable.
The fibre harness should be connected first. Loosen the fibre optic gland in the gland
plate and carefully feed the harness through the gland, insert the common end connector
into the light source aperture and tighten the locking screw to hold it in place. Ensure
the fibre optic connector is fully inserted into the aperture before tightening the gland to
create a seal. Do not overtighten the nylon gland. Never run the luminaire with the fibre
optic harness out of the aperture.
Loosen the gland for the DMX cables and feed the cables carefully through the gland
leaving suicient slack inside the enclosure to reach the back of the light source. Tighten
the gland and fit RJ45 connectors to the cables as detailed in the light source user guide.
Plug the cables into the light source.
Loosen the gland for the mains cable and feed the cable carefully through the gland
leaving suicient slack inside the enclosure to reach the fused terminal block. Prepare
the cable end and wires for connection allowing suicient bare conductor to enter the
terminal fully.
Connect the incoming wires as follows:
• Green to earth
• Black to Live
• White to Neutral
IP-01 WEATHERPROOF ENCLOSURE USER GUIDE

CONNECTION - FOR REMOTE DC OPERATION (DC SUFFIX MODELS)
INSTALLATION
9
UFO LIGHTING
There may up to three connections required to be connected via the appropriate gland:
1. The fibre harness.
2. The DMX cables for the MicroLED 4000 when configured as Master/Slave
3. DC supply cable to the enclosure.
The fibre harness should be connected first. Loosen the fibre optic gland in the gland
plate and carefully feed the harness through the gland, insert the common end connector
into the light source aperture and tighten the locking screw to hold it in place. Ensure
the fibre optic connector is fully inserted into the aperture before tightening the gland to
create a seal. Do not overtighten the nylon gland. Never run the luminaire with the fibre
optic harness out of the aperture.
Loosen the gland for the DMX cables and feed the cables carefully through the gland
leaving suicient slack inside the enclosure to reach the back of the light source. Tighten
the gland and fit RJ45 connectors to the cables as detailed in the light source user guide.
Plug the cables into the light source.
Loosen the gland for the DC cable and feed the cable carefully through the gland leaving
suicient slack inside the enclosure to reach the terminal block. Prepare the cable end
and wires for connection allowing suicient bare conductor to enter the terminal fully.
Connect the incoming wires as follows:
• Red to DC positive
• Black to DC negative
COMPLETING THE CONNECTIONS AND POWERING UP
Once all the connections have been made as detailed in the Installation section of this
user guide and the same corresponding section of the light source user guide, connect
mains power to the enclosure (AC version) or the remote PSU (DC version). If no light is
produced consult the TROUBLESHOOTING section in this manual and the light source
manual.

Date Maintenance Undertaken
Note: A record of all maintenance MUST be kept in the table above, indicating what maintenance
was undertaken and when. This MUST be dated for warranty purposes.
MAINTENANCE
10 IP-01 WEATHERPROOF ENCLOSURE USER GUIDE
Problem Probable Cause Possible Soluon
AC & DC enclosure
model. Unit is dead
– no light output
power indicator on
PSU is out
Mains supply offCheck supply and reinstate
Loose connector(s) Check all required plugs and sockets are fully mated
Blown fuse or circuit tripped Check fuse/trip & replace/reset if necessary. If
problem persists, isolate mains and contact UFO
AC & DC enclosure
model. Unit is dead
– no light output,
power indicator on
Light source not connected correctly Refer to Troubleshoong secon in
light source user guide
Light source not set up correctly Refer to Operaon secon in light source user guide
DC enclosure model.
Unit is dead – no
light output, power
indicator on PSU is
lit
Voltage drop in DC cable too great
Check DC output at PSU and at terminal block
in the enclosure. Increase size of cable or
mount PSU closer to the enclosure
Wiring incorrect DC polarity reversed at
the enclosure
Check polarity at the enclosure terminal block.
Rewire the terminal block correctly.
AC & DC enclosure
model – light output
but some control
funcons not
working
Light source not set up correctly Refer to Troubleshoong and Operaon
secon in light source user guide
AC & DC enclosure
model – light output
but enclosure
running hot
Fan dust filters clogged Remove filters and clean.

MAINTENANCE
11
UFO LIGHTING
TECHNICAL INFORMATION
* Note that the IP protection category only applies when the enclosure is mounted as
specified by UFO - see page 2 for details. Mounting the enclosure in any other way
invalidates the IP rating and the product warranty. UFO will accept no responsibility for
any loss or damage that occurs due to incorrect mounting.
Port Connector Size 30mm
Fibre Type Glass or PMMA
Material & Finish Sheet Steel, RAL7035
Overall Dimensions 300mm x 250mm x 155mm
11.8” x 9.8” x 6.1”
Protecon Category* IP55
Min Ambient Temp. 10°C / 14°F
Max Ambient Temp. 45°C / 113°F
Mains Supply Voltage 240V AC, 50Hz
DC Supply Voltage 12V DC MicroLED 1000
24V DC MicroLED 4000
LED Power (Max.) 5W MicroLED 1000
5W MicroLED 4000
Control Opons MicroLED 1000 Manual
MicroLED 4000 DMX & Manual

DESIGN SPECIFY BUILD INSTALL
United Kingdom •United States •Germany •Europe •UAE
UFO Licht GmbH
Andreasstraße 20
93059 Regensburg \ Deutschland
+49 (0)9491 955880
www.ufo-licht.de
Universal Fiber Optics USA LLC
1749 Northgate Blvd
Sarasota \FL34234 \USA
941-343-8115
www.fiberopticlighting.com
Universal Fibre Optics Ltd
Home Place \Coldstream
TD12 4DT \UK
+44 (0)1890 883416
www.ufo.lighting
This manual suits for next models
4
Table of contents
Other UFO Enclosure manuals