8 Port 10/100Base-TX Switch
with 100Base-FX
Smart-Switch/801
USER’S MANUAL
SC/MM FEP-30109T-C
ST/MM FEP-30109T-T
SC/SM FEP-30109T-C-SM
Model shown: FEP-30109T-C
Smart-Switch/801
1
Features
 Conforms to IEEE 802.3, 802.3u, and 802.3x Ethernet Standards
 Eight auto-sensing 10/100 bps Ethernet RJ-45 ports
 Automatic DI/ DIX crossover for each 10/100Base-TX port
 One Fixed 100 bps Fiber port (SC/ST- ulti- ode, SC-Single
ode)
 Back-Pressure-Base flow control on Half-duplex mode
 Pause-Frame-Base flow control on Full-duplex mode
 Store-and-forward architecture for abnormal packet filtering
 2K-entry AC address table
 96Kbytes memory buffer sharing
 Non-blocking and Full wire speed forwarding rate
 One console port for VLAN configuration and Port Setting
 LED-indicators for Power, 10/100, LK/ACT, and FD/COL
 10" Desktop size design
Smart-Switch/801
2
Package Contents
Unpack the contents of the Smart-Switch/801 and verify them against the
checklist below.
 Smart-Switch/801 Fast Ethernet Switch
 Power Cord
 Four Rubber Feet
 RS-232 console management cable
 User Guide
Smart-Switch/801 Power Cord
Rubber Feet RS-232 cable ser Guide
Figure 1-2. Package Contents
If any item is missing or damaged, please contact your local dealer for
service.
Smart-Switch/801
3
Hardware Description
This section describes the hardware of the Smart-Switch/801.
The physical dimensions of the Smart-Switch/801 are 250mm x 132mm x
37mm (L x W x H)
Front Panel
The Front Panel of the Smart-Switch/801 consists of eight auto-sensing
10/100 bps Ethernet RJ-45 ports with automatic DI/ DIX, one 100Base-
FX fiber port, and the LED indicators.
 Smart-Switch/801 with SC Connector
Figure 2-2. The Front Panel of the Smart-Switch/801 with SC connector
 Smart-Switch/801 with ST Connector
Figure 2-3. The Front Panel of the Smart-Switch/801 with ST connector
 RJ-45 Ports (Auto MDI/MDIX): Eight 10/100 auto- sensing for
10Base-T or 100Base-TX connections.
 100Base-FX Fiber Port: The operating range for the ulti- ode
fiber option is up to 2Km while the SC Single ode fiber variant can
support up to 30Km.
Smart-Switch/801
4
LED Indicators
Figure 2-4. LED Indicators
There are three LED Indicators (10/100 , LNK/ACT, FDX/COL) for each
UTP port and two LED Indicators (LNK/ACT, FDX/COL) for the fiber port.
The following table provides descriptions of the LED status. They provide
a real-time indication of systematic operation.
TP Ports
LED Status Color Description
Power On Green Power On
On Green The port is operating at 100 bps.
10/100
Off The port is operating at 10 bps
or no device attached
On Green The port is successfully connecting
with the device.
Blinks Green The port is receiving or transmitting
data.
LK /ACT
Off No device attached.
On Orange The port is operating in Full-duplex
mode.
Blinks Orange Collision of Packets occurring within
the port.
FDX /COL
Off The port is operating in Half-duplex
mode or no device attached.
Smart-Switch/801
5
Fiber Port
LED Status Color Description
On Green The port is successfully connecting with
the device.
Blinks Green The port is receiving or transmitting
data.
LK /ACT
Off No device attached.
On Orange The port is operating in Full-duplex
mode.
Blinks Orange Collision of Packets occurring within the
port.
FDX /COL
Off The port is operating in Half-duplex
mode or no device attached.
Table 2-1. Descriptions of LED Indicators
Smart-Switch/801
6
Rear Panel
The Console port and 3-pronged power plugs are located at the Rear
Panel of the Smart -Switch/801 as shown in Figure 2-8. This Switch will
work with AC in the 100-240V AC, 50-60Hz. Range.
Figure 2-5 The Rear Panel of the Smart-Switch/801
Console Port: Configuration is done through the console port connector.
This requires a direct connection between the switch and a device such
as a PC or terminal using the supplied RS-232 cable.
Desktop Installation
Set the switch on a sufficiently large flat space with a power outlet
nearby. The surface should be clean, smooth, level, and sturdy.
ake sure there is enough clearance around the Switch to allow air
circulation and the attachment of cables and the power cord.
Smart-Switch/801
7
Attaching Rubber Feet
A_ ake sure mounting surface on the bottom of the Switch is grease
and dust free.
B_ Remove adhesive backing from the Rubber Feet.
C_ Apply the Rubber Feet to each corner on the bottom of the Switch.
These footpads protect the Switch from shock and vibration.
Figure 2-6. Attaching Rubber Feet to each corner on the bottom of the Switch
Power On
Connect the power cord to the power socket on the rear panel of the
Switch. The other end of the power cord connects to the power outlet.
The internal power supply in the Switch works with AC in the 100-
240VAC, frequency 50~60Hz voltage range.
Check the power indicator on the front panel to ensure that power is
properly supplied.
Smart-Switch/801
8
Network Application
This section provides a few samples of network topology in which the
Switch is used.
Desktop Application
The Smart-Switch/801 can be used as a desktop switch, an ideal solution
for a small workgroup. Used as a standalone switch, personal computers,
servers, and printer servers are directly connected to form a small
workgroup.
Figure 3-1. Desktop Application
Smart-Switch/801
9
Segment Application
For enterprise networks where large data broadcast are constantly
processed, this switch is ideal for connecting workgroups or departments
to the corporate backbone.
Figure 3-2. Segment Applications
Connect PCs, workstations, and servers to each other by connecting
these devices directly to the Smart-Switch/801. All devices in this
network can communicate with one another as well as with central
servers.
The Switch automatically learns node addresses, which are subsequently
used to filter and forward all traffic based on the destination address. You
can interconnect each of your small, switched workgroups to form a
larger switched network through any of the RJ-45 ports of the Smart-
Switch/801.
Smart-Switch/801
10
Smart-Switch/801
PRINTERCOMPUTER
SERVER COMPUTER
Smart-Switch/801
Fiber Optic
Connection
(2km - MM)
(30km - SM)
200Mbps
Figure 3-3. Use fiber port (Smart-Switch/801) to extend the distance between workgroups
In the above illustration, two Smart-Switch/801 switches are used to
connect two small workgroups. By using fiber ports to connect switches,
the distance between the two switches can extend up to 2Km ( ulti-
ode) or 30Km (Single ode fiber).
Smart-Switch/801
11
Network Configuration
This Section explains how to configure VLAN features via a direct
connection to the console port on the rear panel of the Smart-Switch/801.
This port is a female DB-9 connector. From the main menu of the
console program, the user can configure various functions of the switch.
Connecting a Terminal or
PC to the Console Port
Figure 4-1. Connecting the Smart-Switch/801 to a terminal via RS-232 cable
Use the supplied RS-232 cable to connect a terminal or PC to the
console port. The terminal or PC to be connected must support a
terminal emulation program.
Once connected, turn on the PC and run a standard terminal emulation
program such as Hyper Terminal or Windows Terminal to match the
following default characteristics of the switch console port:
Smart-Switch/801
12
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow Control: None
Figure 4-2. The settings of
communication parameters
After you have finished parameter settings, press “OK“. The main
console management menu should appear. (You need to reboot the
Switch to show ain enu)
Smart-Switch/801
13
Console Management
Console Configuration enables use of a local console terminal or PC to
control ports and VLANs on the Smart-Switch/801.
Main Menu
The ain enu shows all available switch configuration options.
Figure 4-3. The ain enu of Console anagement
Per Port Setting
From the ain enu, choose the 1st Item by typing “ 1 “ into the blank.
The following screen appears (see fig 4-4). The default Per Port Settings
are all Auto Negotiation and the default fiber port setting is 100 / Full-
duplex mode.
To modify a port's status, first choose the port number. In the following
example, we choose Port 1 by typing “1". Five different port duplex
modes are available: Auto-Negotiation, Force to 100M and FDX mode,
Force to 10M and FDX mode, Force to 100M and HDX mode, Force to 10M
and HDX mode. The Fiber port also features four configurable modes.
(see Figure 4-5). Type in the required item number here to set the port
duplex mode.
Smart-Switch/801
14
Figure 4-4. The default Per Port Setting
Figure 4-5. Port statuses to configure
Setting VLAN
A VLAN (Virtual LAN) is a group of switch ports designated by the switch
as belonging to the same broadcast domain. This feature allows
workgroups to be defined on the basis of their logical location instead of
their physical location.
VLANs also help isolate broadcast traffic and increase security.
Smart-Switch/801
15
Grouping the switch ports into broadcast domains and assigning them to
the same VLAN increases performance and network capacity. oreover,
VLAN groups can be modified at any time to add, remove, or change
users without any re-cabling.
From the ain enu, choose the second item “ Setting VLAN “ by typing
“ 2 “. Follow the VLAN Setup enu. The switch can support up to nine
VLAN groups.
Figure 4-6. VLAN Setup enu
First, type in the port number and the prompt displays “Enter VLAN ID
number ( 1..9 )”. Then choose the required VLAN group number by
typing the VLAN ID number. Type in “ 1 “ to add to this VLAN ID or “ 2 “
to remove from this VLAN. The display will now show the new setting.
Smart-Switch/801
16
Figure 4-7. The process of creating VLAN group
Continue to configure the other ports with another VLAN group. In the
following example, we create three VLAN groups (VLAN 1: Port 4, 5, 6;
VLAN 2: Port 1, 2, 3, 4; VLAN 3: Port 4, 7, 8, 9) and the 4th port may be
connected to an IS member.
Restore Factory Setup
If you make a mistake while setting up any of the menus, you can easily
restore the switch setting to the factory default by selecting the main
menu, choosing the 3rd item, “Restore Default Setup”, by typing “3”. The
switch will reset to the original factory settings.
Reset Device
If the switch performs improperly or if you want to reboot the switch, go
back to ain enu and select the 4th item by typing “ 4 “ to reboot the
Switch.
Smart-Switch/801
17
Troubleshooting
This section helps solve the most common problems on the Smart-
Switch/801.
Incorrect connections
 Faulty or Loose Cables
Look for loose or obviously faulty connections. If they appear to be OK,
make sure the connections are snug. If that does not correct the problem,
try a different cable.
 Non-standard cables
Non-standard and miswired cables may cause numerous network
collisions and other network problem and can seriously impair network
performance. A Category 5e cable tester is a recommended tool for
every 100Base-T network installation.
 Improper Network Topologies
It is important to make sure that you have a valid network topology.
Common topology faults include excessive cable length and too many
repeaters ( hubs ) between end nodes. In addition, you should make sure
that your network topology contains no data path loops. Between any two
end nodes, there should be only one active cabling path at any one time.
Data path loops will cause broadcast storms that will severely impact
your network performance.
Smart-Switch/801
18
LED Diagnostic Indicators
The Switch status can be easily monitored through panel indicators. If the
power indicator does not light when the power cord is plugged in, you
may have a problem with AC power outlet or power cord. However, if the
Switch powers off once running, Check for loose power connections,
power losses, or surges at the AC power outlet. If you still cannot resolve
the problem, contact your local dealer for assistance.
■ Improper Network Topologies
RJ-45 ports: Use unshielded twisted-pair (UTP) or shielded twisted-pair
(STP) cable for RJ-45 connections: Category 3, 5e or 6 cable for 10 bps
or Category 5e and 6 cable for 100 bps connections. Ensure that the
length of any twisted-pair connection does not exceed 100 meters ( 328
feet ).
100Base-FX fiber port: The ulti- ode Fiber connector type must use
50/125 or 62.5/125µm fiber cable. You can connect two devices over
a distance of up to 2km. However, the Single ode Fiber connector must
use 9/125µm Single ode fiber cable. You can connect two devices up
to 30 kilometers apart in full duplex operation, utlilizing Single ode
format.
Smart-Switch/801
19
Technical Specifications
Standards Compliance IEEE 802.3 10Base-T Ethernet,
IEEE 802.3u 100Base-TX/FX Fast Ethernet
IEEE 802.3x Flow Control
Protocol CS A/CD
Max Forwarding and
Max Filtering Rate
14,880 pps per Ethernet port,
148,800 pps per Fast Ethernet port
Packet size 64 ~ 1522 bytes
LED Diagnostic Indicators Per Port: (10/100 UTP ) :
10/100 , LK/ACT, FD/COL ( 3 LEDs )
Fiber Port: LK/ACT, FD/COL ( 2 LEDs )
Per Unit: Power
Copper Network Cables 10Base-T: 2-pair UTP/STP Cat5e/6 cable
EIA/TIA-568 100-ohm ( 100m )
100Base-TX: 2-pair UTP/STP Cat5e/6 cable
EIA/TIA-568 100-ohm ( 100m )
Fiber Link Max. Distance SC/ST, ulti-mode: 2km
SC, Single-mode: 30km
Dimensions 250mm x 132mm x 37mm (L x W x H)
Weight 1050 ±20 g
Storage Temp. -40ºC to 70ºC ( -40ºF to 158ºF)
Operational Temp. 0ºC to 45ºC ( 32ºF to 113ºF )
Operational Humidity 10% to 90% (Non-condensing)
External Power 100-240V AC, 50-60Hz
Power Consumption 10 Watts ( ax )
EMI FCC Class B, CE ark
Safety UL, cUL

This manual suits for next models

5

Other Uni-Com Switch manuals

Uni-Com GEP-32005T User manual

Uni-Com

Uni-Com GEP-32005T User manual

Uni-Com SmartPoE/2402M User manual

Uni-Com

Uni-Com SmartPoE/2402M User manual

Uni-Com POE-35055T User manual

Uni-Com

Uni-Com POE-35055T User manual

Uni-Com SmartGST-900GM GEP-66109T User manual

Uni-Com

Uni-Com SmartGST-900GM GEP-66109T User manual

Uni-Com DynaGST/2402G GEP-33224T-1 User manual

Uni-Com

Uni-Com DynaGST/2402G GEP-33224T-1 User manual

Uni-Com MicroGST/5 GEP-32005T User manual

Uni-Com

Uni-Com MicroGST/5 GEP-32005T User manual

Uni-Com Dyna-Switch/24 fep-31024t-2 User manual

Uni-Com

Uni-Com Dyna-Switch/24 fep-31024t-2 User manual

Uni-Com FEP-32008T-3 User manual

Uni-Com

Uni-Com FEP-32008T-3 User manual

Uni-Com SmartGST-2600M User manual

Uni-Com

Uni-Com SmartGST-2600M User manual

Uni-Com SmartGST-2404GM GEP-66424T User manual

Uni-Com

Uni-Com SmartGST-2404GM GEP-66424T User manual

Uni-Com SmartPoE/802M User manual

Uni-Com

Uni-Com SmartPoE/802M User manual

Uni-Com SmartGST-2402 GEP-31124T-1 User manual

Uni-Com

Uni-Com SmartGST-2402 GEP-31124T-1 User manual

Uni-Com GST-2402 User manual

Uni-Com

Uni-Com GST-2402 User manual

Uni-Com Smart-Switch/801M FEP-60109T-C User manual

Uni-Com

Uni-Com Smart-Switch/801M FEP-60109T-C User manual

Uni-Com 8 User manual

Uni-Com

Uni-Com 8 User manual

Uni-Com DynaGST/1602G GEP-33216T User manual

Uni-Com

Uni-Com DynaGST/1602G GEP-33216T User manual

Uni-Com MicroGST/5 GEP-32005T User manual

Uni-Com

Uni-Com MicroGST/5 GEP-32005T User manual

Uni-Com Pro-Switch 8F User manual

Uni-Com

Uni-Com Pro-Switch 8F User manual

Uni-Com Smart GST-900M User manual

Uni-Com

Uni-Com Smart GST-900M User manual

Uni-Com fep-31024t-2 User manual

Uni-Com

Uni-Com fep-31024t-2 User manual

Uni-Com DynaGST/1602G GEP-33216T User manual

Uni-Com

Uni-Com DynaGST/1602G GEP-33216T User manual

Uni-Com FEP-31024T-3 User manual

Uni-Com

Uni-Com FEP-31024T-3 User manual

Uni-Com Smart-Switch/801 FEP-30109T-C User manual

Uni-Com

Uni-Com Smart-Switch/801 FEP-30109T-C User manual

Uni-Com FEP-32024T User manual

Uni-Com

Uni-Com FEP-32024T User manual

Popular Switch manuals by other brands

Goobay 58971 user manual

Goobay

Goobay 58971 user manual

Southern States ESD63 Installation instructions manual

Southern States

Southern States ESD63 Installation instructions manual

StarTech.com IES51000POE Spec sheet

StarTech.com

StarTech.com IES51000POE Spec sheet

Pickering 40-193 user manual

Pickering

Pickering 40-193 user manual

Hama 00011576 user manual

Hama

Hama 00011576 user manual

Vimar Eikon manual

Vimar

Vimar Eikon manual

Korenix JetNet 3808G Series user manual

Korenix

Korenix JetNet 3808G Series user manual

ATEN VanCryst VS0801A Quick start guides

ATEN

ATEN VanCryst VS0801A Quick start guides

Kramer VP-443 user manual

Kramer

Kramer VP-443 user manual

DeLOCK 87729 user manual

DeLOCK

DeLOCK 87729 user manual

StarTech.com ST7300U3M instruction manual

StarTech.com

StarTech.com ST7300U3M instruction manual

Zamel TWILIGHT SWITCH WZM-02 instruction manual

Zamel

Zamel TWILIGHT SWITCH WZM-02 instruction manual

Niles IPC-6 install guide

Niles

Niles IPC-6 install guide

Cerio HS Series user guide

Cerio

Cerio HS Series user guide

H3C S3610series Operation manual

H3C

H3C S3610series Operation manual

Viessmann VITOPLANAR operating instructions

Viessmann

Viessmann VITOPLANAR operating instructions

Synology S7210-8P-130W user manual

Synology

Synology S7210-8P-130W user manual

Planet Networking & Communication IGS-5225 Series user manual

Planet Networking & Communication

Planet Networking & Communication IGS-5225 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.