OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends
referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2019 Unified Brands.
All Rights Reserved.
888-994-7636, fax 888-864-7636
unifiedbrands.net
PART NUMBER PP MNL1702, REV. E (08/19)
This manual provides information for:
9550/52-290 DROP-IN SERIES
FREEZER/PLATE CHILLER
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation,operating and maintenance
instructions thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Unified
Brands suggests that if you are suspicious of damage to make a notation
on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Unified Brands
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODELNUMBER_________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
The serial number is located in the cabinet left side
under the electrical box. An example is shown here.
EQUIPMENT DESCRIPTION
MODEL LENGTH DEPTH HEIGHT NO. OF
OPENINGS STORAGE
(CUBIC FEET)
GALLON
CAPACITY COUNTER
CUTOUT
POWER
USAGE KW
(PER DAY) COMPRESSOR VOLT AMPS NEMA SHIP WT
(LBS)
9550-290 28.375” 17.1875” 27” 11.8 626" x 15.75" 0.95 1/4 115/60/1 2.0 5-15P
125
9552-290 28.375” 28.375” 27” 13.36 11.2 26" x 26" 1.34 1/4 115/60/1 2.0 5-15P
165
INSTALLATION
CAUTION:
THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT. USE CAUTION WHEN
HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER. AVOID
DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK.
WARNING:
FAILURE TO FOLLOW INSTALLATION GUIDELINES AND
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.
WARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE.
CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE
FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON
THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.
WARNING: THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL,
INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE
SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15.
SELECTING A LOCATION FOR YOUR NEW UNIT
The following conditions should be considered when selecting a location for your
unit:
1. Floor & Countertop Load: The area on which the unit will rest must be level,
free of vibration, and suitably strong enough to support the combined weights
of the unit plus the maximum product load weight. NOTE: If there is a question
pertaining to weight load limits, consult the factory at 1-888-994-7636.
2. Secure & Seal: Once the drop in unit is installed into the counter it can be
secured to the countertop by using the brackets supplied from the factory.
a. Secure unit to top and seal with “NSF” approved silicone.
b. Install inside duct with thumb screws and adjust outside duct to fit
between condenser coil and counter’s louvered cutout
c. Secure outside duct in place with screws through pre-punched holes.

2 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
3. Clearance: See installation diagrams for minimum compartment dimension.
Do not place any object that can block the ventilation exhaust from the
machine compartment register. 10 inch clearance at each of the louvered
ends of the unit.Area of equipment must be free of all combustible materials.
4. Ventilation: The air cooled self contained unit requires a sufficient amount
of cool clean air. Avoid surrounding your unit around other heat generating
equipment and out of direct sunlight. Also, avoid locating in an unheated
room or where the room temperature may drop below 55°F (13°C) or rise
above 86°F (32°C).
INSTALLATION CHECKLIST
WARNING: IT ISIMPORTANT THAT AVOLTAGE READING BE MADEAT THE COMPRESSOR
MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION
TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS
BEING SUPPLIED. LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT
OPERATION AND THEREBY VOID ITS WARRANTY.
CAUTION:
UNIT MUST BE INSTALLED INTO IT’S OWN COMPARTMENT TO PROPERLY
CONTAIN ANY REFRIGERANT LEAK. IT IS RECOMMENDED THAT NO ARCHING
POTENTIAL COMPONENTS BE IN THIS COMPARTMENT WITH THE EXCEPTION
OF A SINGLE GFCI OUTLET TO POWER THE UNIT.
After the final location has been determined, refer to the following checklist prior
to start-up:
1. Units must be installed in a minimum compartment size as indicated in the
installation drawing. Provided louvers must be installed in accordance with
the installation drawings to ensure proper ventilation for system operation
or in the event of a refrigerant leak. NOTE: It is recommended that ONLY a
single GFCI outlet be located in the compartment where the unit is installed.
No other arching potential components are allowed.
2. Follow cut out dimensions provided for specific models to properly size the
opening for your drop in.
3. Check cord and plug of unit to assure no damage has occurred to these
components.
4. Check all exposed refrigeration lines to ensure that they are not kinked,
dented, or rubbing together.
5. Check that the condenser and evaporator fans rotate freely without striking
any stationary members.
6. Plug in unit and turn on main on/off power button on the controller.
7. Allow unit time to cool down to temperature. If temperature adjustments are
required, the control is located on the front panel. Confirm that the unit is
holding the desired temperature.
8. Refer to the front of this manual for serial number location. Please record
this information in your manual on page 3 now. It will be necessary when
ordering replacement parts or requesting warranty service.
9. Confirm that the unit is holding temperature. Set control to desired
temperature for your particular ambient and altitude.
10. Before putting in product, allow your unit to operate for approximately two
(2) hours so that interior of the unit is cooled down to storage temperature.
9550-290 INSTALLATION
COMPARTMENT
IMPORTANT - READ FIRST - IMPORTANT
INTERIOR EVAPORATOR COVER
EXTERIOR OF UNIT
NEAR EXPOSED REFRIGERANT TUBING
NEAR MACHINE COMPARTMENT AND NAMEPLATE

3 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
9552-290 INSTALLATION
COMPARTMENT
ELECTRICAL SUPPLY
Any wiring should be done by a qualified electrician in accordance with all
national and local electrical codes. A properly wired and grounded outlet will
assure proper operation. Please consult the data tag attached to the compressor
to ascertain the correct electrical requirements. Supply voltage and amperage
requirements are located on the serial number tag.
OPERATION
Allow unit to operate for approximately two (2) hours before placing in food.
AMBIENT CONDITIONS
Unit is designed for normal operating temperatures between 70° F (21°C) - 86°F
(32°C). Operating outside of those temperatures may cause premature product
wear or failure.
Unified Brands has attempted to preset the temperature control to ensure that
your unit runs at an optimum temperature, but due to varying ambient conditions,
including elevation, food type and your type of operation, you may need to alter
this temperature using control adjustment until desired temperature is reached.
It is normal for the refrigerated cold well to develop an even layer of frost during
operation. NOTE:Keeping the hinged cover closed as much as possible will prevent
excessive frost buildup.
MORNING STARTUP
1. Cold pan cleaning may be performed at this time.
2. Turn on unit with switch located in the mechanical compartment.
3. Allow 30 minutes for the cold pan to cool down before loading product.
4. Load the product and proceed with food preparation. NOTE: Product entering
the cold pan must be at 40°F or less.
EVENING SHUT DOWN
Remove product from the cold pan at the end of the day’s preparation. The product
may be discarded or stored in any commercial refrigerator.
1. Turn off unit with switch located in the mechanical compartment. This will
allow unit to thaw which allows for better operation when starting up unit for
next day operation.
2. Unit cleaning may be performed at this time once the frost has melted off the
surface. NOTE:Water may form small pools and have to be pushed to the drain
for 100% draining.
DANFOSS CONTROLLER OPERATION
LED FUNCTION
Compressor energized & Evaporator fan de-energized
Defrost in progress
Fans delay after defrost completion
Evaporator fan energize
An alarm is occurring
ºC / ºF Temperature unit
POWER ON / OFF
MANUAL DEFROST
CHANGE SET POINT
POWER ON / OFF: Press and hold the power button until LED display turns On / Off
MANUAL DEFROST: Press and hold “Defrost” Button
CHANGE SET POINT: To raise temperature
1. Press and hold “ ” to access set point.
2. When set point start flashing, Press “ ” to adjust set point.
3. After 30 seconds, the display automatically reverts to showing the current
temperature.
CHANGE SET POINT: To lower temperature
1. Press and hold “v” to access set point.
2. When set point start flashing, Press “v” to adjust set point.

4 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
3. After 30 seconds, the display automatically reverts to showing the current
temperature.
CHANGE FROM ºF /ºC :
1. Press the up/down buttons simultaneously for 5 seconds to access the menu.
2. Password is requested. Password is 000.
3. Press the bottom left button to OK the password.
4. Using the up/down buttons, navigate to the “diS” level. Press the bottom left
button to OK the selection.
5. Using the up/down buttons, navigate to the “CFu” level. Press the bottom left
button to OK the selection.
a. “-F” designates Fahrenheit.
b. “-C” designates Celsius.
6. Press the top left button repeatedly to return to exit and return to the home
screen.
MAINTENANCE
WARNING: DO NOT USE SHARP UTENSILS AND/OR OBJECTS.
WARNING: DO NOT USE STEEL PADS, WIRE BRUSHES, SCRAPERS, OR CHLORIDE
CLEANERS TO CLEAN YOUR STAINLESS STEEL.
CAUTION: DO NOT USE ABRASIVE CLEANING SOLVENTS, AND NEVER USE
HYDROCHLORIC ACID (MURIATIC ACID) ON STAINLESS STEEL.
Unified Brands strongly suggests a preventive maintenance program which would
include the following monthly, weekly, and daily procedures:
If a failure of the equipment is a direct result of any of the Preventative Maintenance
guidelines being neglected, the repairs and parts replacements will not be covered
under warranty.
It is recommended that the customer contact the local Authorized Service Agent to
provide a quote to perform periodic Preventative Maintenance.
MONTHLY PROCEDURES
1. Cleaning of all condenser coils. Condenser coils are a critical component in
the life of the compressor and must remain clean to assure proper air flow and
heat transfer. Failure to maintain this heat transfer will affect unit performance
and eventually destroy the compressor. Clean the condenser coils with coil
cleaner and/or a vacuum cleaner and brush. NOTE: Brush coil in direction of
fins, normally vertically as to not damage or restrict air from passing through
condenser.
2. Clean fan blades on the condensing unit and evaporator assembly.
3. Clean and disinfect drain lines and evaporator pan with a solution of warm
water and mild detergent.
4. Clean all gaskets on a weekly if not daily basis with a solution of warm water
and a mild detergent to extend gasket life.
5. Lubricate door hinges with lithium grease.
RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE
FOLLOWING:
JOB CLEANING AGENT COMMENTS
Routine cleaning Soap, ammonia,
detergent Medallion Apply with a sponge or
cloth
Fingerprints and smears Arcal 20, Lac-O-Nu,
Ecoshine Provides a barrier film
Stubborn stains and
discoloration Cameo, Talc, Zud,
First Impression Rub in the direction of
the polish lines
Greasy and fatty acids, blood,
burnt-on foods Easy-Off, Degrease It,
Oven Aid Excellent removal on all
finishes
Grease and Oil Any good commercial
detergent Apply with a sponge or
cloth
Restoration/Preservation Benefit, Super Sheen Good idea monthly
Reference: Nickel Development Institute, Diversey Lever, Savin, Ecolab, NAFEM
Proper maintenance of equipment is the ultimate necessity in preventing costly
repairs. By evaluating each unit on a regular schedule, you can often catch
and repair minor problems before they completely disable the unit and become
burdensome on your entire operation.
For more information on preventive maintenance, consult your local service
company or CFESA member. Most repair companies offer this service at very
reasonable rates to allow you the time you need to run your business along with
the peace of mind that all your equipment will last throughout its expected life.
These services often offer guarantees as well as the flexibility in scheduling or
maintenance for your convenience. For a complete listing of current Unified Brands
ASA please visit www.unifiedbrands.net.
Unified Brands believes strongly in the products it manufactures and backs those
products with one of the best warranties in the industry. We believe with the
proper maintenance and use, you will realize a profitable return on your investment
and years of satisfied service.
REPLACEMENT PARTS
To order parts, contact your Authorized Service Agent. Supply the model
designation, serial number, part description, part number, quantity, and when
applicable, voltage and phase.
CONTACT US
If you have questions pertaining to the content in this manual, contact Unified
Brands at 888-994-7636.

5 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
TROUBLESHOOTING
This unit is designed to operate smoothly and efficiently if properly maintained.
However, the following is a list of checks to make in the event of a problem. Wir-
ing diagrams are found at the end of this manual. When in doubt, turn unit off
and contact service at 888-994-7636.
SYMPTOM POSSIBLE CAUSE PROCEDURE
Unit does not run
No power to unit Plug in unit
Control in OFF position Turn controller on
Faulty control Call for service at
888-994-7636
Unit too cold Incorrect set point Adjust control set point
Unit too warm
Lid open Ensure lid is fully closed
Gasket torn or out of place Inspect the gasket for wear
and position
Incorrect set point Adjust control set point
Warm product introduced
to cabinet Pre-chill product -3ºF
Unit noisy Vibration in the cabinet Inspect for loose parts
DANFOSS CONTROLLER CODES
DISPLAYED
ALARM CODE
ALARM ACTION
Hi High Temperature Alarm Inspect door/drawer sealing
Contact service
Lo Low Temperature Alarm Contact service
CON Condenser Temperature
High Limit
Clean condenser coil
Inspect coil for any objects
obstruction hindering airflow
Contact service
uHi Line Voltage Too High
Verify voltage of power source,
to be performed by qualified
technician
Contact service
uLi Line Voltage Too Low
Verify voltage of power source,
to be performed by qualified
technician
Contact service
LEA Continuous Compressor
Runtime
Inspect door/drawer sealing
Inspect condenser coil, clean if
necessary
Contact service
E01 S1 Sensor Failure Contact service
E02 S2 Sensor Failure Contact service
E03 S3 Sensor Failure Contact service
E04 S4 Sensor Failure Contact service
SERVICE
CAUTION: COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS.
SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE
PERSONNEL, SO AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO
INCORRECT PARTS OR IMPROPER SERVICE.
CAUTION: BEFORE MAKING ANY REPAIRS, ENSURE THE UNIT IS DISCONNECTED
FROM ITS POWER SOURCE.
This piece of equipment uses a R290 Refrigeration system. This equipment has
been clearly marked on the serial tag the type of refrigerant that is being used.
There is also a warning labels stating that the unit contains R290 refrigerant. R290
is safe to use as long as you follow these warning labels.
No smoking or open flames when servicing this equipment. If needed, use a CO2
or powder type fire extinguisher.
Replacement parts used on any R290 Refrigeration system cabinet must have
specific UL certification for non-sparking components.
Only authorized service technician, certified in R290 system should service this
equipment.
MANIFOLD SET
A R134A manifold set can be used for servicing this equipment.
REFRIGERANT RECOVERY
Follow all national and local regulations for R-290 refrigerant recovery.
LEAKING CHECKING AND REPAIR
Leak check an R-290 system the same way you would an R-134a or R-404A
system with the following exceptions.
1. Do not use a Halid leak detector on a R290 system.
2. Electronic leak detector must be designated specifically for combustible gas.
Use of a bubble solution or an ultrasonic leak detector are acceptable.
When repairing a leak, it is recommended using oxygen free dry nitrogen with a
trace gas not exceeding 200PSI.
When accessing an R290 system, piercing valves are not to remain on the
equipment in a permanent manner. After charge is recovered, Schrader valves
are to be installed on the process stubs. Proper charge is to be weighed into the
system and the system is to be leak checked afterwards.
The R290 equipment must have red process tubes and other devices through
which the refrigerant is serviced, such as any service port. This color marking
must remain on the equipment. If marking is removed, it must be replace and
extend at least 2.5 centimeters (1”) from the compressor.
CHARGING
Follow the charge amount specified on the data tag. It is recommended to use the
shortest hoses possible to prevent undercharging.
• Ensure the system is sealed and leak checked
• Evacuate system to a minimum 500 micron
• Weigh in correct charge
• Leak check the system again
• Bleed the refrigerant from the high side hose to the low side hose
• Disconnect the hoses
• Remove line taps

6 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
Parts List
ITEM PART NUMBER DESCRIPTION
1 RP CLP0102 HOLD DOWN CLIP COLD PANS AND PLATE CHILLERS
2 RP COV1703 COVER, REMOVABLE COND UNIT HOUSING, 9550,9552-290
3 RP DGH1701 DOGHOUSE, INNER PORTION, 9550&52-290 (T17-0049E-D14)
4 RP DGH1702 DOGHOUSE, OUTER PORTION, 9550&52-290 (T17-0049F-D17)
5 RP LVR0003 LOUVER, 14" X 26" DROP INS
6EL WIR461-90 POWER CORD, 9' 16/3 W/90* PLUG000461-RT (SJTO WIRE)
7EL WIR469A POWER CORD, 14/3 18" FEMALE
8 HD GRD1610 FAN GUARD, NICKEL CHROM FINISH , 116M RND
9 HD LID200 LID, 23.25" X 22.75", DLRS-200, 9552-290
10 RF CMP1606 COMPRESSOR, EMBRACO EM2X1121U, R290, 115V/60HZ
10a RF CMP1606SC COMPRESSOR START COMPONENTS
11 RP CNT1702 CONTROL, DANFOSS PRE-PROGRAMMED 9550/52-290
12 RF CNT1603 THERMISTOR, QTI, AIR SENSOR - BLACK, 10'
13 RF COI1606 COIL, COND. 3.46" X 9" X 5.9", 1/4" TUBE
14 RF FAN0601 FAN, AXIAL, 127MM X 38MM 120CFM, 115V CONDENSER
15 RF FLT9902 FILTER DRYER, 1/4x.042 FILTER, EKP-032 SC DBL INL CAP TUBE
16 RP CAP1702 WRAP, HEAT EXCHANGE, .026 X 13' CAP TUBE W/ 8' HEAT EXCHANGE
17 HD LID111 LID, 10.25" X 20.25" SLRS-111, 9550-290

7 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
Electrical Schematic

8 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
Service Log
Model No: Purchased From:
Serial No: Location:
Date Purchased: Date Installed:
Purchase Order No: For Service Call:
Date Maintenance Performed Performed By

MANUEL DE L’USAGER
RENSEIGNEMENTS IMPORTANTS À L’INTÉRIEUR.
À CONSERVER POUR L’USAGER.
888-994-7636, fax 888-864-7636
unifiedbrands.net
NUMÉRO DE PIÈCE PP MNL1702, REV. E (09/19)
Ce manuel contient des informations sur l’installation,
l’utilisation, l’entretien, le dépannage et le remplacement
des pièces pour :
9550/52-290 MODÈLES ENCASTRÉS
CONGÉLATEUR / PLAQUE REFROIDISSANTE
CE MANUEL DOIT ÊTRE CONSERVÉ AFIN DE POUVOIR S’Y RÉFÉRER PLUS
TARD. VEUILLEZ LIRE, COMPRENDRE ET SUIVRE ATTENTIVEMENT LES
CONSIGNES ET AVERTISSEMENTS CONTENUS DANS CE MANUEL.
AVERTISSEMENT / POUR VOTRE SÉCURITÉ Ne pas ranger ou utiliser du
carburant ou autres vapeurs ou liquides inflammables à proximité de cet
appareil ou de tout autre appareil.
AVERTISSEMENT Le réfrigérant inflammable R290 est utilisé. Une
installation, ajustement, modification, service ou entretien inadéquat
peuvent causer des dommages matériels, des blessures corporelles, ou
entraîner la mort. Veuillez lire les consignes d’installation, d’utilisation et
d’entretien attentivement avant d’effectuer l’installation ou l’entretien de
cet appareil.
AVISEZ IMMÉDIATEMENT LE TRANSPORTEUR DE TOUT DOMMAGE
Le destinataire a la responsabilité d’inspecter le conteneur dès la
réception et de déterminer la présence de tout dommage, incluant
les dommages non apparents. Si vous pensez que l’appareil a
été endommagé, Unified Brands suggère de le mentionner sur le
bordereau de livraison. Il est de la responsabilité du destinataire
de présenter une demande d’indemnité au transporteur. Nous vous
recommandons de le faire sans délai.
Pour toutes questions sur la fabrication ou le service, 888-994-7636
IMPORTANT - À LIRE EN PREMIER
AVIS :À cause de son programme d’amélioration continue de produit, Unified Brands
se réserve le droit d’effectuer sans préavis des modifications à la conception et aux
caractéristiques.
AVIS : Veuillez lire attentivement ce manuel au complet avant l’installation. Si
certaines procédures recommandées ne sont pas suivies, les réclamations de
garantie seront refusées.
NUMÉRO DE MODÈLE _____________________
NUMÉRO DE SÉRIE _______________________
DATE D’INSTALLATION ____________________
Le numéro de série se trouve dans le meuble, du côté gauche, sous la boîte électrique.
Voir l’exemple ci-dessous.
DESCRIPTION DE L’ÉQUIPEMENT
MODÈLE LONGUEUR PROFONDEUR HAUTEUR NOMBRE
D’OUVERTURES
RANGEMENT
(PIED CUBE)
CAPACITÉ
(GALLON)
DÉCOUPAGE DU
COMPTOIR
CONSOMMATION
ÉLECTRIQUE (KW)
(PAR JOUR)
COMPRESSEUR VOLTS AMPS NEMA
POIDS À
L’EXPÉDITION
(LB)
9550-290 72,07 cm
(28,375 po)
43,66 cm
(17,1875 po)
68,58 cm
(27po) 1 1,8 6 66 x 40 cm
(26po x 15,75po) 0,95 1/4 115/60/1 2,0 5-15P
125
9552-290 72,07 cm
(28,375 po)
72,07 cm
(28,375 po)
68,58 cm
(27po) 1 3,36 11,2 66 x 66 cm
(26po x 26 po) 1,34 1/4 115/60/1 2,0 5-15P
165
INSTALLATION
MISE EN GARDE !
CET APPAREIL CONTIENT DU RÉFRIGÉRANT INFLAMMABLE R290.
SOYEZ PRUDENT LORSQUE VOUS MANIPULEZ, DÉPLACEZ OU UTILISEZ
LE RÉFRIGÉRATEUR OU LE CONGÉLATEUR. ÉVITEZ D’ENDOMMAGER
LE TUYAU RÉFRIGÉRANT OU D’AUGMENTER LE RISQUE DE FUITES.
AVERTISSEMENT:CETAPPAREILESTCONÇUPOURÊTREUTILISÉDANSLESLABORATOIRES
D’ÉTABLISSEMENTS COMMERCIAUX, INDUSTRIELS OU INSTITUTIONNELS,
TEL QUE DÉFINI DANS LES NORMES DE SÉCURITÉ POUR LES SYSTÈMES
DE RÉFRIGÉRATION, ASHRAE 15.
AVERTISSEMENT: NE PAS RESPECTER LES DIRECTIVES ET RECOMMANDATIONS
LORS DE L’INSTALLATION POURRAIT INVALIDER LA GARANTIE DE VOTRE
APPAREIL.
AVERTISSEMENT: IL EST IMPORTANT QUE VOTRE APPAREIL AIT UNE LIGNE SPÉCIFIQUE.
LE GROUPECOMPRESSEUR-CONDENSEUR ESTCONÇU POUR FONCTIONNER
AVEC UNE FLUCTUATION DE TENSION DE PLUS OU MOINS 10% DE LA
TENSION INDIQUÉE SUR L’ÉTIQUETTE DE DONNÉES DE L’APPAREIL. LA
GARANTIE SERA INVALIDÉE SI LE GROUPE COMPRESSEUR-CONDENSEUR
EST ENDOMMAGÉ PARCE QUE LES LIMITES DE TENSION ONT ÉTÉ
DÉPASSÉES.
LA COMMANDE DANFOSS EST MUNIE D’UNE PROTECTION CONTRE
LES BAISSES DE TENSION ET NE DISTRIBUERA PAS DE TENSION AU
COMPRESSEUR SI ELLE EST INFÉRIEURE À 104V.
Les renseignements contenus dans ce document sont reconnus comme étant à jour et exacts au moment de la rédaction et de l’impression.
Unified Brands recommande de consulter le site Web de nos gammes de produits, unifiedbrands.net, pour obtenir les renseignements et
spécifications les plus à jour. © 2019 Unified Brands.Tous droits réservés.

10 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
SÉLECTIONNER UN EMPLACEMENT POUR VOTRE NOUVEL APPAREIL
Les facteurs suivants doivent être considérés lorsque vous sélectionnez un
emplacement pour votre appareil :
1. Charge sur le plancher et le comptoir : La surface sur laquelle l’appareil va
être installé doit être au niveau, ne doit pas être sujette aux vibrations, et
assez résistante pour supporter le poids de l’appareil et le poids maximum
de produits qui peuvent être rangés à l’intérieur.
2. Fixer et sceller : Une fois que l’appareil encastré est installé dans le comptoir,
il peut être fixé à l’aide des attaches fournies par Unified Brands.
a. Fixer l’appareil au comptoir et le sceller avec un silicone homologué
« NSF ».
b. Installer le conduit intérieur avec les vis de serrage et ajuster le conduit
extérieur pour qu’il soit placé entre le serpentin du condenseur et les
fentes découpées dans le comptoir.
c. Fixer le conduit extérieur en vissant les vis dans les trous poinçonnés.
3. Dégagements : Voir les schémas de montage pour les dimensions minimum
du compartiment. Ne placez pas d’objet qui pourrait obstruer les évents du
compartiment de l’appareil. Un espacement de 25,4 cm (10 po) à chaque
extrémité des persiennes de l’appareil. La zone autour de l’appareil doit être
exempte de matières combustibles.
4. Ventilation : L’unité indépendante refroidie à l’air demande une quantité
suffisante d’air frais. Évitez de placer votre appareil près d’autres appareils
qui génèrent de la chaleur et placez-le à l’abri de la lumière directe du soleil.
De plus, évitez de le placer dans une pièce qui n’est pas chauffée ou une
pièce dont la température peut descendre sous 55°F ou s’élever au-dessus
de 86°F.
LISTE DE VÉRIFICATION POUR L’INSTALLATION
AVERTISSEMENT: IL EST IMPORTANT D’EFFECTUER LES LECTURES DE TENSION À LA
HAUTEUR DES RACCORDS DU MOTEUR ÉLECTRIQUE DU COMPRESSEUR
ALORS QUE L’APPAREIL FONCTIONNE POUR S’ASSURER QUE LA
BONNE TENSION EST ALIMENTÉE AU COMPRESSEUR. LES BASSES ET
HAUTES TENSIONS PEUVENT AVOIR DES EFFETS NÉFASTES SUR LE
FONCTIONNEMENT, ANNULANT PAR LE FAIT MÊME LA GARANTIE.
MISE EN GARDE !
L’APPAREIL DOIT ÊTRE INSTALLÉ DANS SON PROPRE COMPARTIMENT
POUR CONTENIR EFFICACEMENT UNE FUITE DE RÉFRIGÉRANT. IL EST
RECOMMANDÉ DE NE PAS INSTALLER DES COMPOSANTS QUI POURRAIENT
CAUSER UN ARC ÉLECTRIQUE DANS LE COMPARTIMENT, À L’EXCEPTION
D’UN DISJONCTEUR DE FUITE DE TERRE POUR ALIMENTER L’APPAREIL.
Après avoir déterminé l’emplacement de l’appareil, référez-vous à la liste de
vérification suivante avant de commencer :
1. Les appareils doivent être installés dans un compartiment en respectant
les dimensions minimum indiquées dans le schéma d’installation. Les
persiennes fournies doivent être installées conformément aux indications
sur les schémas d’installation pour assurer une ventilation adéquate lors du
fonctionnement du système ou lors d’une fuite du réfrigérant. REMARQUE :
Il est recommandé d’utiliser UN seul disjoncteur de fuite de terre, placé
dans le compartiment où l’appareil est installé. Il n’est pas permis d’utiliser
d’autres composants qui pourraient causer un arc électrique.
2. Suivre la découpe des dimensions indiquées pour un modèle particulier pour
bien découper l’ouverture pour encastrer l’appareil.
3. Vérifier le cordon et la prise de l’appareil pour s’assurer que les composants
n’ont pas été endommagés.
4. Assurez-vous que les conduites de réfrigération apparentes ne sont pas
déformées, bosselées, et qu’elles ne frottent pas les unes contre les autres.
5. Assurez-vous que les ventilateurs du condenseur et de l’évaporateur
tournent librement, sans heurter des pièces fixes.
6. Brancher l’appareil et mettre l’appareil sous tension en utilisant le bouton
marche/arrêt sur la commande.
7. Laissez l’appareil refroidir à la température désirée. Si vous devez ajuster
la température, la commande se trouve sur le panneau avant. Assurez-vous
que la température de l’appareil est constante.
8. Le numéro de série se trouve au début du manuel. Veuillez enregistrer
l’information à la page 23 de votre manuel avant de continuer. Il est
nécessaire pour commander des pièces de remplacement ou demander un
service de garantie.
9. S’assurer que la température de l’appareil est constante. Régler la
commande à la température désirée pour les conditions ambiantes et
l’altitude où vous vous trouvez.
10. Avant de placer des aliments, laissez l’appareil fonctionner pour environ
deux (2) heures pour permettre à l’intérieur de l’appareil d’atteindre la
température de rangement.
IMPORTANT - À LIRE EN PREMIER
INTÉRIEUR DU PANNEAU DE L’ÉVAPORATEUR
EXTÉRIEUR DE L’APPAREIL
PRÈS DU TUYAU RÉFRIGÉRANT APPARENT
PRÈS DU COMPARTIMENT DE LA MACHINE ET DE LA PLAQUE SIGNALÉTIQUE

11 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
9550-290 INSTALLATION
HAUTEUR
MINIMUM
68,58 CM (27 PO)
64,77 CM
(25 1/2 PO)
40 CM
(15 3/4 PO)
26 CM
(26 PO)
38 CM (15 PO)
30,5 CM (12 PO)
35,56 CM (14 PO)
60,33 CM
(23 3/4 PO)
CIRCULATION D’AIR
RÉGLAGE DE
10 – 20 CM
(4 - 8 PO)
PANNEAUS À PERSIENNE
(POUR LES ENDROITS ÉTROITS,
LES PERSIENNES PEUVENT
ÊTRE TOURNER DE 90°)
10 CM (4 PO)
MINIMUM
DIMENSIONS MINIMUM DU
COMPARTIMENT 76 CM (30 PO) DE
PROFONDEUR X 51 CM (20 PO) DE
LARGEUR
66 CM
(26 PO)
72,07 CM
(28,375 PO)
43,66 CM (17,188 PO)
39 CM (15,375 PO)
68,26 CM
(26,875 PO)
37,15 CM
(14,625 PO
38,74 CM
(15,25 PO)
29,21 CM (11,5 PO)
20 CM
(8 PO)
CONDUIT D’AIR RÉGLABLE
RÉGLAGE DE 10 – 20 CM
(4 – 8 PO)
PANNEAUX D’ACCÈS
AMOVIBLES SUR LES CÔTÉS
GAUCHE ET DROIT DU
CONDENSEUR
THERMOSTAT
ÉLECTRONIQUE
64,77 CM
(25,5 PO)
9552-290 INSTALLATION
64,77 CM
(25 1/2 PO)
40 CM
(26 PO)
66 CM
(26 PO)
HAUTEUR
MINIMUM
68,58 cm (27 PO)
CIRCULATION D’AIR
RÉGLAGE DE
10 – 20 CM
(4 - 8 PO)
LE COUVERCLE PEUT ÊTRE
TOURNÉ DE 90°, SELON LE BESOIN
PANNEAUS À PERSIENNE
(POUR LES ENDROITS
ÉTROITS, LES PERSIENNES
PEUVENT ÊTRE TOURNER
DE 90°)
DIMENSIONS MINIMUM DU
COMPARTIMENT 76 CM (30 PO)
DE PROFONDEUR X 76 CM (30 PO)
DE LARGEUR
66 CM
(26 PO)
38 CM (15 PO)
30,5 CM (12 PO)
35,56 CM (14 PO)
60,33 CM
(23 3/4 PO)
10 CM (4 PO)
MINIMUM
72,07 cm
(28,375 PO)
72,07 cm
(28,375 PO)
59 CM
(23,25 PO)
68,26 CM
(26,875 PO)
39 CM
(15,375 PO)
29,21 CM
(15,375 PO)
1 37,15 CM
(4,625 PO)
64,77 CM
(25,5 PO)
64,77 CM
(25,5 PO)
57,8 CM
(22,75 PO)
CONDUIT D’AIR RÉGLABLE
RÉGLAGE DE 10 – 20 CM (4 – 8 PO)
PANNEAUX D’ACCÈS
AMOVIBLES SUR LES
CÔTÉS GAUCHE ET DROIT
DU CONDENSEUR
THERMOSTAT
ÉLECTRONIQUE
20 CM
(8 PO)
ALIMENTATION ÉLECTRIQUE
Lecâblagedoitêtreeffectuéparunélectriciencompétent,conformémentauxcodes
nationauxetlocauxd’électricité.Uneprise de courant correctement câblée etmise
à la terre assure un bon fonctionnement.Voir l’étiquette de données apposée sur
le compresseur pour déterminer les besoins électriques. Les besoins en tension
d’alimentation et d’intensité de courant sont situés sur l’étiquette du numéro de
série.
UTILISATION
Laissez l’appareil fonctionner pendant environ deux (2) heures avant de ranger de
la nourriture.
CONDITIONS AMBIANTES
L’appareil est conçu pour fonctionner à des températures entre 0° F (21°C) -
86°F (32°C). S’il n’est pas utilisé dans les limites de ces températures, l’appareil
pourrait s’user ou tomber en panne prématurément.
Unified Brands a tenté de prérégler la commande de température pour s’assurer
que votre appareil fonctionne à la température optimale, cependant, en raison des
conditions ambiantes, incluant l’altitude, le type d’aliments et l’utilisation, il est
possible que vous deviez ajuster la température requise en utilisant le réglage de
la commande.
FONCTIONNEMENT DE LA COMMANDE DANFOSS
DEL FUNCTION
Compresseur en marche & ventilateur de l’évaporateur
hors tension
Dégivrage en cours
Ventilateurs hors tension jusqu’à la n du cycle de dé-
givrage
Ventilateur de l’évaporateur en marche
Une alarme est activée
ºC / ºF Unité de température
TOUCHE
MARCHE /
ARRÊT
DÉGIVRAGE MANUEL
CHANGER LA VALEUR DE
RÉGLAGE
TOUCHE MARCHE / ARRÊT : Appuyer sur la touche de mise en marche jusqu’à ce
que l’écran DEL s’allume ou s’éteigne.
DÉGIVRAGE MANUEL : Appuyer sur la touche « Dégivrage »
CHANGER LA VALEUR DE RÉGLAGE : Pour augmenter la température
1. Appuyer sur « » pour accéder la valeur de réglage
2. Lorsque la valeur clignote, appuyer sur « » pour ajuster la valeur désirée
3. Après 30 secondes, l’écran affiche automatiquement la température actuelle

12 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
CHANGER LA VALEUR DE RÉGLAGE : Pour abaisser la température
1. Appuyer sur « v » pour accéder la valeur de réglage
2. Lorsque la valeur clignote, appuyer sur « v » pour ajuster la valeur désirée
3. Après 30 secondes, l’écran affiche automatiquement la température actuelle
CHANGER DE ºF / ºC :
1. Appuyer sur les touches haut / bas en même temps pendant 5 secondes pour
accéder au menu.
2. Un mot de passe est nécessaire. Le mot de passe est 000.
3. Appuyer sur la touche inférieure gauche pour Confirmer le mot de passe.
4. En utilisant les touches haut / bas, naviguer jusqu’au niveau « diS ». Appuyer
sur la touche inférieure gauche pour Confirmer la sélection.
5. En utilisant les touches haut / bas, naviguer jusqu’au niveau « CFu ». Appuyer
sur la touche inférieure gauche pour Confirmer la sélection.
a. « -F » indique les degrés Fahrenheit.
b. « C » indique les degrés Celsius.
6. Appuyer sur la touche supérieure gauche à plusieurs reprises pour quitter et
retourner à l’écran d’accueil.
ENTRETIEN
AVERTISSEMENT: NE PAS UTILISER D’USTENSILES ET / OU D’OBJETS TRANCHANTS.
AVERTISSEMENT: NE PAS UTILISER DES TAMPONS À RÉCURER, DES BROSSES
MÉTALLIQUES, DES GRATTOIRS,OU DES NETTOYANTS AU CHLORURE POUR
NETTOYER L’ACIER INOXYDABLE.
MISE EN GARDE ! : NE PAS UTILISER DE SOLVANTS DÉTACHANTS ABRASIFS, ET NE
JAMAIS UTILISER D’ACIDE HYDROCHLORIQUE (ACIDE MURIATIQUE) SUR
L’ACIER INOXYDABLE.
AVERTISSEMENT: NE PAS UTILISER UNE MACHINE DE LAVAGE À HAUTE PRESSION,
VOUS POURRIEZ ENDOMMAGER LES COMPOSANTS ÉLECTRIQUES.
Unified Brands recommande fortement un programme d’entretien préventif qui
comprend les procédures Mensuelles suivantes :
MONTHLY PROCEDURES
1. Nettoyage des serpentins du condenseur. Les serpentins sont des composants
essentiels pour la durée de vie du compresseur et doivent rester propres pour
assurer une circulation d’air et un transfert thermique adéquats. À défaut
de maintenir le transfert thermique va affecter le rendement de l’appareil
et éventuellement endommager le compresseur. Nettoyer les serpentins
du condenseur avec un nettoyant pour serpentins et/ou un aspirateur
et une brosse. REMARQUE: Brosser le serpentin dans le sens des ailettes,
normalement verticalement, pour ne pas endommager ou restreindre l’arrivée
d’air à travers le condenseur.
2. Nettoyer les pales de ventilateur du groupe compresseur-condenseur et de
l’évaporateur.
3. Nettoyer et désinfecter les conduits de drainage et le bac de l’évaporateur
avec une solution d’eau tiède et un détergent doux.
4. Nettoyer tous les joints d’étanchéité au moins une fois par semaine (tous les
jours de préférences) avec une solution d’eau tiède et d’un détergent doux
pour prolonger la vis des joints.
5. Lubrifier les charnières de porte avec de la graisse au lithium.
LES PRODUITS NETTOYANTS SUIVANTS SONT RECOMMANDÉS POUR L’ACIER
INOXYDABLE :
JOB PRODUIT NETTOYANT COMMENTS
Nettoyage périodique Savon, ammoniac,
détergent Medallion
Utiliser une éponge ou
un linge
Les empreintes et les taches Arcal 20, Lac-O-Nu,
Ecoshine
Procure une couche
protectrice
Taches tenaces et
décoloration
Cameo, Talc, Zud,
First Impression
Frotter dans la direction
des lignes de polissage
Acides graisseux, sang,
aliments brûlés
Easy-Off, Degrease It,
Oven Aid
Excellent détachant pour
tous les nis
Graisse et huile Tout bon détergent
commercial
Utiliser une éponge ou
un linge
Restauration / protection Benet, Super Sheen Utilisation mensuelle
recommandée
Référence: Nickel Development Institute, Diversey Lever, Savin, Ecolab, NAFEM
Un bon entretien de l’appareil est essentiel pour éviter des réparations coûteuses.
En vérifiant chacun des appareils de façon régulière, vous
pouvez souvent déceler et réparer des petits problèmes, avant
qu’ils ne causent une panne importante et engendrent des
coûts supplémentaires pour votre entreprise.
Pour plus d’information sur la maintenance préventive, consultez une entreprise
locale ou un membre du CFESA. La plupart des entreprises de réparation
offrent ce service à un prix raisonnable, cela vous permet de concentrer
plus de temps à votre entreprise tout en sachant que votre appareil sera
en bonne condition tout au long de sa durée de vie prévue. Ces services
offrent souvent des garanties et une plus grande souplesse pour s’adapter
à votre horaire pour effectuer l’entretien. Pour une liste complète des ASA de
Unified Brands, veuillez visiter notre site www.unifiedbrands.net.
Unified Brands croit en la qualité des produits qu’il fabrique, c’est pourquoi il offre
une des meilleures garanties de l’industrie. Nous croyons qu’avec un entretien et
une utilisation appropriés, votre investissement sera rentable et que vous allez
pouvoir en profiter pendant plusieurs années.
PIÈCES DE RECHANGE
Pour commander des pièces, contactez votre agent de service autorisé. Fournir
la désignation du modèle, le numéro de série, la quantité de numéro de pièce de
description et, le cas échéant, la tension et la phase.
CONTACTEZ-NOUS
ISi vous avez des questions concernant le contenu dans le contact manuel
Unified Brands à.

13 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
DÉPANNAGE
Cet appareil est conçu pour fonctionner de façon optimale et efficace s’il est
convenablement entretenu. Cependant, si vous rencontrez des problèmes, voici
une liste de vérification à effectuer. Les schémas de câblage se trouvent à la fin
du manuel. En cas de doute, éteindre l’appareil et appeler le 888-994-7636 pour
obtenir du service.
SYMPTOM CAUSE POSSIBLE PROCÉDURES
L’appareil ne
fonctionne pas
L’appareil n’est pas
alimenté Brancher l’appareil
Commande à la position
ARRÊT Allumer la commande
Commande défectueuse Appelez le 888-994-7636
pour du service
Appareil trop froid Valeur de réglage incorrecte Régler la valeur de réglage de
la commande
Appareil trop chaud
Couvercle ouvert Assurez-vous que le couvercle
est complètement fermé
Joint d’étanchéité déchiré
ou déplacé
Vérifier l’usure et la position
du joint d’étanchéité
Valeur de réglage incorrecte Régler la valeur de réglage de
la commande
Des produits chauds sont
rangés dans le meuble
Refroidir les aliments à une
température de -3ºF pour le
congélateur
Appareil bruyant Vibration dans le meuble Assurez-vous qu’il n’y a pas
de pièces desserrées
DANFOSS
ALARM CODE ALARM ACTION
Hi Alarme à haute température
Vérifier l’étanchéité de la porte
/ du tiroir
Contact service
Lo Alarme basse température Contact service
CON Limite élevée de
température condensateur
Nettoyer le serpentin du
condenseur
Inspecter la bobine pour
détecter toute obstruction
empêchant la circulation de l’air
Contact service
uHi Tension de ligne trop élevée
Vérifier la tension des sources
d’alimentation, à effectuer par
un technicien qualifié
Contact service
uLi Tension de ligne trop basse
Vérifier que la tension de source
d’alimentation, à être effectuée
par un technicien qualifié
Contact service
LEA Runtime continu du
compresseur
Vérifier l’étanchéité de la porte
/ du tiroir
Inspecter le serpentin du
condenseur, nettoyer si
nécessaire
Contact service
E01 S1 défaillance du capteur Contact service
E02 S2 défaillance du capteur Contact service
E03 S3 défaillance du capteur Contact service
E04 S4 défaillance du capteur Contact service
ENTRETIEN
MISE EN GARDE ! : LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES
COMPOSANTS IDENTIQUES. LES TRAVAUX D’ENTRETIEN DOIVENT ÊTRE
EFFECTUÉS PAR DU PERSONNEL D’ENTRETIEN AUTORISÉ POUR MINIMISER
LES RISQUES D’INFLAMMATION CAUSÉE PAR DES PIÈCES DE MAUVAISE
QUALITÉ OU UN MAUVAIS ENTRETIEN.
MISE EN GARDE ! : AVANT D’EFFECTUER DES RÉPARATIONS, ASSUREZ-VOUS QUE LES
UNITÉS SONT DISONNECTED DE SES SOURCES D’ÉNERGIE.
Cet appareil utilise un système de réfrigération R290. Le type de réfrigérant utilisé
est clairement indiqué sur l’étiquette du numéro de série de l’appareil. De plus, des
étiquettes de mise en garde indique que l’appareil contient du réfrigérant R290.
R290 est sûr à utiliser tant que vous suivez ces étiquettes d’avertissements.
Ne pas fumer ou utiliser une flamme nue lors de l’entretien de l’appareil. Au
besoin, utiliser un extincteur à CO2 ou à poudre chimique
Seul un technicien d’entretien autorisé, certifié pour le système R290, doit
effectuer l’entretien sur cet équipement.
ENSEMBLE DE JAUGE DE RÉFRIGÉRATION
Un ensemble de jauge de réfrigération R134A peut être utilisé pour l’entretien de
l’appareil.
RÉCUPÉRATION DES RÉFRIGÉRANTS
Suivre la réglementation nationale et locale pour la récupération du réfrigérant
R290.
VÉRIFIER POUR ET RÉPARER LES FUITES
Vérifier pour des fuites du système R290 de la même façon que pour les systèmes
R134A ou R404A, avec les exceptions suivantes.
1. Ne pas utiliser une lampe haloïde pour le système R290.
2. Le détecteur électronique de fuites doit être spécialement conçu pour le gaz
combustible.
Vous pouvez utiliser une solution à bulles ou un détecteur de fuites par ultrasons.
Lorsque vous réparez une fuite, il est recommandé d’utiliser un azote sec exempt
d’oxygène avec une trace de gaz inférieure à 200 PSI.
Lorsque vous accédez au système R290, les robinets vannes ne doivent pas
être installés sur l’appareil de façon permanente. Après avoir récupéré le
gaz réfrigérant, des vannes Schrader doivent être installées sur les montants
d’entretien. La quantité de gaz doit être mesurée avant d’être insérée dans le
système, vous devez ensuite vérifier le système pour des fuites.
Les tubes d’entretien de l’équipement du R290, et les autres dispositifs utilisés
pour l’entretien du gaz réfrigérant,comme les ports de service,doivent être rouges.
Ce marquage de couleur doit demeurer sur l’appareil. Si le marquage est effacé,
il doit être remplacé et prolongé au moins jusqu’à 2,5 cm (1 po) du compresseur.
REMETTRE DU GAZ
Utiliser la quantité de gaz précisée sur l’étiquette de données. Il est recommandé
d’utiliser les tuyaux les plus courts possible pour vous assurer d’utiliser la bonne
quantité.
• S’assurer que le système est étanche et qu’il n’y a pas de fuites
• Vidanger le système à un minimum de 500 micromètres
• Mesurer la bonne quantité de gaz
• S’assurer que le système de fuit pas
• Purger le gaz réfrigérant de la partie supérieure du tuyau vers la partie
inférieure tuyau
• Débrancher les tuyaux
• Enlever les prises de ligne

14 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
Liste des pièces
ITEM NUMÉRO DE PIÈCE DESCRIPTION
1 RP CLP0102 PINCE DE RETENUE POUR LES RÉCIPIENTS FROIDS ET LES PLAQUES REFROIDISSANTES
2 RP COV1703 COUVERCLE AMOVIBLE DU BOÎTIER DU CONDENSEUR, 9550,9552-290
3 RP DGH1701 PARTIE INTERNE DE LA HOUSSE, 9550&52-290 (T17-0049E-D14)
4 RP DGH1702 PARTIE EXTERNE DE LA HOUSSE, 9550&52-290 (T17-0049F-D17)
5 RP LVR0003 PERSIENNE À GLISSIÈRE, 35,56 CM X 66 CM (14 PO X 26 PO)
6EL WIR461-90 CORDON D’ALIMENTATION, 9 PI 16/3 W/90* PLUG000461-RT (FIL SJTO)
7EL WIR469A CORDON D’ALIMENTATION FEMELLE, 14/3 45,7 CM (14/3 18 PO)
8 HD GRD1610 GRILLE DE PROTECTION, FIL EN NICKEL-CHROME, ROND, 116M
9 HD LID200 COUVERCLE, 59 CM X 57,8 CM (23,25 PO X 22,75 PO), DLRS-200, 9552-290
10 RF CMP1606 COMPRESSEUR EMBRACO EM2X1121U, R290, 115V/60HZ
10a RF CMP1606SC COMPOSANTS DE DÉMARRAGE DU COMPRESSEUR
11 RP CNT1702 COMMANDE PRÉPROGRAMMÉE DANFOSS, 9550/52-290
12 RF CNT1603 THERMISTANCE DE LA SONDE DE TEMPÉRATURE QTI, NOIRE, 10 PI
13 RF COI1606 TUYAU DU SERPENTIN DU CONDENSEUR. 8,8 CM X 22,86 CM X 15 CM, 0,64 CM (3,46PO X 9PO X 5,9PO, 1/4 PO)
14 RF FAN0601 VENTILATEUR AXIAL DU CONDENSEUR, 127MM X 38MM 120CFM, 115V
15 RF FLT9902 FILTRE DE SÉCHOIR, 1/4 X 0,042, EKP-032 SC, AVEC TUYAU À DOUBLES OUÏES
16 RP CAP1702 ENVELOPPE DE L’ÉCHANGEUR DE CHALEUR, 0,026 X 13 PI AVEC TUYAU
D’ÉCHANGEUR DE CHALEUR DE 8 PI
17 HD LID111 COUVERCLE, 26,04 CM X 51,44 CM (10,25 PO X 20,25 PO) SLRS-111, 9550-290

15 OM-9550/52-290 MODÈLES ENCASTRÉS CONGÉLATEUR / PLAQUE REFROIDISSANTE
Schéma électrique
TOUCHE DIRECTE
16FLA(72RLA)
16(10)A
240V-
16A 10A 10A
1 2 3 4 5
LIGNES D’ALIMENTATION
120V 50-60hz
BLANC
BRUN
BLANC
BLANC
COMPRESSEUR
VENTILATEUR DU CONDENSEUR
PROTECTION CONTRE LES SURCHARGES
COMPRESSEUR
CONDENSATEUR DE MARCHE PTC
PRISE
NEMA
5–15
VERT
BLANC
BLANC
COMP
BRUN
NOIR
BLANC
ALIMENTATION
115V–60HZ–1PH
CORDE AVEC MISE À LA TERRE
NEMA # 5–15P
NOTE :
NOIR (AIR) = S1

16 OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER
Journal d'entretien
N° de modèle: Acheté de:
N° de série: Emplacement:
Date d'achat: Date d'installation:
N° du bon de commande: Pour un appel de service:
Date Entretien effectué Effectué par
This manual suits for next models
1
Table of contents
Languages:
Other Unified Brands Commercial Food Equipment manuals

Unified Brands
Unified Brands power soak INTRO Manual

Unified Brands
Unified Brands Randell RAN SCA-2 User manual

Unified Brands
Unified Brands INTEK XS Series User manual

Unified Brands
Unified Brands Groen EE Series User manual

Unified Brands
Unified Brands Randell 2300 Series User manual

Unified Brands
Unified Brands Randell DPM Series User manual

Unified Brands
Unified Brands groen ECLIPSE BPM-15 User manual

Unified Brands
Unified Brands Power Soak SILVER SOAK User manual