Unilamp VOLGA 7411-O-2-561-91 User manual

1/4
INSTALLATION MANUAL
PRODUCT NAME : VOLGA - CV Wall Recess Under Water
1
Light Emitting Diodes
(LED)
1-6
2
Gel-Filled IP68 Connector Cable Diameter 4.8-6mm.
Available separately.
Ordering Code/ÃËÑÊÊÑè§«×éÍ : 9-0906-00
Cable size : 2x0.75 mm.
Ø
4.8-6mm.
¢¹Ò´ÊÒÂä¿
74
2
Torque/áçºÔ´ : 1 Nm.
2.1 2.2
2.3
2.4
1
2
3
PVC pipe 1"
¢¹Ò´·Í PVC 1 ¹ÔéÇ
FR-DM-17 REV.03 EFF 15/09/17
Apply PVC glue to
prevent water leakage.
·Ò¡ÒÇPVCà¾×èͻͧ¡Ñ¹¹éíÒÃÑèÇ
·ÕèÃÐËÇÒ§¡ÅͧPVC
Last Revised On : 21/06/2021 REV.01
û1"
û70
108
112
141
-
+
VOLGA - CC Wall Recess Under Water
IP68
lll
No.
Ordering Code
1.
2.
3.
7411-0/A/B/C/H-2-561-91
Input
7411-0/A/B/C/H-2-562-91
7411-0/A/B/C/H-2-563-91
7412-0/A/B/C/H-2-561-91
7412-0/A/B/C/H-2-562-91
7412-0/A/B/C/H-2-563-91
4.
5.
6.
(CV)Constant Voltage-remote
driver/12Vdc
(CC)Constant Current 1200mA
remote driver
2 Meters cable pre-wired
from the factory.
ÊÒÂä¿ÂÒÇ2àÁµÃ»ÃСͺÁÒ
¾ÃÍÁ¡ÑºµÑÇâ¤Á¨Ò¡âç§Ò¹
141
105

2/4
4
FR-DM-17 REV.03 EFF 15/09/17
5
Installation complete
¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó
3
For OD-7411
PRISEC
InputOutput
Output/ÍÍ¡
L N
Please prepare the space for installation.
¤ÇÃàµÃÕÂÁ¾×é¹·Õèà¼×èÍÊíÒËÃѺ¡ÒõԴµÑé§äÇ´ÇÂ
DIstance from the luminaire to transformer /Driver should not exceed 10 meters.
ÃÐÂÐËÒ§ÃÐËÇÒ§µÑÇâ¤Á¶Ö§ËÁÍá»Å§ËÃ×Íä´ÃàÇÍÃäÁ¤ÇÃà¡Ô¹ 10 àÁµÃ
Accessory available separately./ÍØ»¡Ã³ àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡
Ordering Code Product Name
Maximum quantity of luminaire
parallel connection
0448-0-9-000-00 LED Constant Voltage Driver 12Vdc 30W.
Driver IP67 without GFR Polymer Box 1-5 luminaires
0276-0-9-000-01 LED Constant Voltage Driver 12Vdc 12W.
In IP67 GFR Polymer Box 1-2 luminaires
Input/à¢Ò
220-240V
to Luminaires
Input/à¢Ò
Distance from the luminaire to transformer /Driver should not exceed 10 meters.
ÃÐÂÐËÒ§ÃÐËÇÒ§µÑÇâ¤Á¶Ö§ËÁÍá»Å§ËÃ×Íä´ÃàÇÍÃäÁ¤ÇÃà¡Ô¹ 10 àÁµÃ
RED
BLACK
Please prepare the space for
installation.
¤ÇÃàµÃÕÂÁ¾×é¹·Õèà¼×èÍÊíÒËÃѺ
¡ÒõԴµÑé§äÇ´ÇÂ
For OD-7412
220-240V
Output/ÍÍ¡
to Luminaire
L N
LN
Accessory available separately./ÍØ»¡Ã³ àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡
Ordering Code Product Name
Maximum quantity of luminaire
Series Circuit connection
0426-0-9-000-00 LED Constant Current Driver 1200mA 6W.
In IP67 GFR Polymer Box 1 luminaire
Control box
µÙ¤Çº¤ØÁÃкºä¿¿Ò
Max
¤ÇÒÁÅÖ¡ÁÒ¡ÊØ´
1.5 m
.
L1
L2
L1+L2 =
Max 10 meters.
ÃÐÂÐÁÒ¡ÊØ´ 10 àÁµÃ
Distance from the luminaire to transformer should not exceed 10 meters.
ÃÐÂÐËÒ§ÃÐËÇÒ§µÑÇâ¤Á¶Ö§ËÁÍá»Å§äÁ¤ÇÃà¡Ô¹ 10 àÁµÃ
3
6
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 21/06/2021 REV.01

3/4
Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm.
Ø 4.8-6 mm.
2
The luminaire should be positioned so that prolonged staring into the luminaire at
a distance closer than 0.5m in not expected.
µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢Ò´Ç§µÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹
ÃÐÂйÍ¡ÇÒ 0.5 Á.
Any damaged safety glass cover must be replaced only with the original
spare part.
àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹
FR-DM-17 REV.03 EFF 15/09/17
Not using chemical compounds and aggressive agents such as , weed repellents
fertilizers , acid solvent and contaminated irrigation water near the Luminaires.
ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ
ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿
1.
2.
Warning :
¢Í¤ÇÃÃÐÇѧ
The manufacturer will not be liable or held responsible
for any incorrect installation, misuse or improper use
and unauthorised modification to the fittings. Failure
to comply with mentioned warning may cause serious
damage or serious injury to persons, animals or
objects. If any modification is required please consult
your dealer for the details.
·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒÃ
µÔ´µÑé§äÁ¶Ù¡ÇÔ¸Õ, 㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ
«Öè§ ÊÔè§¼Ô´»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãË à¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ
ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡Òûà ѺᵧµÑÇâ¤Á
ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµ ͵ÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ
Where damage has occured to the fittings, please
make the replacement with standard parts before use.
㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒÂ¡ÃØ³Òà»ÅÕ蹪Ôé¹Êǹ
ãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑÂ
1.
2.
3.
4.
5.
Remark :
ËÁÒÂà˵Ø
Installation should be carried out by a qualified
electrician in accordance with appropriate national
wiring regulation.
¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò
·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò ã¹¡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò
â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò
Disconnect the power before changing the lamp.
»´ÊÇÔ·ªä¿·Ø¡¤ÃÑé§·Õèà»ÅÕè¹ËÅÍ´ä¿
This is class 3 luminaire fixture.
â¤Á俪¹Ô´¹Õé¨Ñ´ÍÂÙã¹ »ÃÐàÀ· 3 ( CLASS III ) ¤×Íãªä¿âÇÅ·µèíÒ
Do not exceed the maximum wattage.
ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ·
Don't touch LED while maintaining or cleaning.
ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃØ§ÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 21/06/2021 REV.01
LED
Our products are installed with electronic components with the protection against
overvoltage according to IEC 61547. The customers have to install the additional
overvoltage protection devices (against surge, transients, etc) in their electrical
system to avoid the risk of damage. Failing to do so can cause the end
of products warranty.
¼ÅÔµÀѳ±¢Í§àÃÒä´ÃѺ¡ÒõԴµÑé§Ãкº»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547
ÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹à¾ÔèÁàµÔÁ(હ »Í§¡Ñ¹ä¿¡ÃЪҡ ÏÅÏ )
ã¹Ãкºä¿¿Òà¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕÂËÒ·ÕèÍÒ¨¨Ðà¡Ô´¢Öé¹ ËÒ¡ÅÙ¡¤ÒäÁ·íÒ¡ÒõԴµÑé§à¾ÔèÁ
àµÔÁÍÒ¨·íÒãË¡ÒÃÃѺ»ÃСѹÊÔ¹¤ÒÊÔé¹Êشŧ

Environmental protection: Waste electrical products should not be disposed of
with household waste. please recycle where facilities exist.check with your local
authority or retailer for recycling advice.
ËÒÁ·Ôé§¼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æ àÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹ
â»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æ áÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁ
à¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫éíÒ
«Ö觨ЪÇ»ͧ¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ôé§¢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ
4/4 FR-DM-17 REV.03 EFF 15/09/17FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 21/06/2021 REV.01
Clean the products regularly to maintain good light output and prolong surface
quality .
Only use solvent-free cleaning solutions on the products.
·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂØ¤Ø³ÀÒ¾¾×é¹¼ÔÇ
㪹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹
Do not use a high pressure washer to clean the products.
ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±
This manual suits for next models
29
Other Unilamp Spotlight manuals
Popular Spotlight manuals by other brands

LIVARNO LUX
LIVARNO LUX LSL 10 A4 Operating instructions and safety instructions

IMG STAGE LINE
IMG STAGE LINE PARL-183RGB instruction manual

Heath Zenith
Heath Zenith SL-5502 manual

LIVARNO LUX
LIVARNO LUX 288476 Assembly, operating and safety instructions

North Light
North Light JF-CP005-UK Instruction

PULSE+
PULSE+ PLS00571 quick start guide