Unique Automation Bathomatic Basic MK3 User manual

®
Basic User Interface MK3
User Guide
bathomaticautomated bath filler and shower control
These instructions are to be left with the user
COPYRIGHT 2007-2016, UNIQUE AUTOMATION

COPYRIGHT 2016, UNIQUE AUTOMATION - 2 - 08/11/2016 12:57
Contents
Introduction................................................................................................................3
Graphics Display........................................................................................................4
Quick Start.................................................................................................................5
Presets.......................................................................................................................5
Running a preset....................................................................................................5
Changing a preset..................................................................................................6
Saving a preset ......................................................................................................6
Hand Shower.............................................................................................................7
Drain Operation..........................................................................................................7
Closing the drain.....................................................................................................7
Opening the drain...................................................................................................7
Main menu.................................................................................................................8
Set Up Menu............................................................................................................10
Depth Calibration..................................................................................................10
Set Level...........................................................................................................10
0% - bath calibration.........................................................................................10
100% - bath calibration.....................................................................................11
Temperature Offset ..............................................................................................11
Temperature Calibration.......................................................................................11
Reset....................................................................................................................11
Trouble Shooting..................................................................................................12

COPYRIGHT 2016, UNIQUE AUTOMATION - 3 - 08/11/2016 12:57
Introduction
Thank you for purchasing this quality product from Unique Automation. To enjoy the
full potential of your new product, please take time to read this guide. Having done
so, keep it handy for future reference.
bathomatic is a fully automated bath management system and shower control
designed to remove the chores of bath filling and water temperature maintenance
leaving the pleasurable part of the bathing experience.
bathomatic can be controlled by a range of interfaces and this guide covers the use
of the bathomatic Basic User Interface (BUI). Below are simple instructions allowing
users to run a bath and alter their preferences using the easy to navigate BUI with its
function/navigation buttons and graphics display.
Basic User Interface - BUI
Function buttons
Shower
Drain
Menu
Presets
Confirmation
Navigation buttons
Depth up, Menu up
Depth down, Menu down
Temperature UP, Menu right
Temperature Down, Menu left

COPYRIGHT 2016, UNIQUE AUTOMATION - 4 - 08/11/2016 12:57
Graphics Display
When the bath is empty or BUI is not used for few minutes BUI goes into
hibernation and its graphics display goes blank. To make the system ready for use
you need to touch any function or navigation button and the graphics below will
appear indicating bathomatic status: Current bath water temperature and depth and
the last called / desired water temperature and depth.
bathomatic status: Filling - when bathomatic is filling
Pause - bathomatic filling/draining is paused
1
Draining / emptying - when bathomatic is draining “DRAINING”
Empty –“CHOOSE TEMP & DEPTH”
Ready –“READY WHEN YOU ARE”
Water Temperature the temperature of the water in the bath
Water Depth the depth of the water in the bath
Desired Temperature the temperature value last sent to bathomatic
Desired Depth the depth value last sent to bathomatic
1
Pressing the button during filling or draining will put bathomatic in paused status awaiting further
instructions. Pressing the button again will change status to filling and followed by the
button will change status to draining.

COPYRIGHT 2016, UNIQUE AUTOMATION - 5 - 08/11/2016 12:57
Quick Start
Touch the BUI if the graphics display is blank. The graphics display will light up
showing the current and desired temperature and depth. Should you wish to run
the same bath again press
To increase/decrease the desired water temperature
2
use / and to
increase/decrease the desired water depth use / . Pressing will start filling to
the new values.
The desired values for water temperature and depth can be altered when
bathomatic is empty and is not filling or draining. Should you wish to change the
desired temperature and depth when bathomatic is filling or draining press which
will pause bathomatic, then change the values and press and hold again for
bathomatic to resume filling to the new settings.
Presets
bathomatic stores 9 presets with individual temperature, depth and fragrance
selection.
Running a preset
From the preset menu using the / buttons select the presets you wish to run
followed by the confirmation button . Each preset indicates temperature and
depth in this menu.
2
Maximum allowed temperature is 43°C
bathomatic runs Preset One
Presets
Preset One
Preset Nine
bathomatic runs Preset Nine

COPYRIGHT 2016, UNIQUE AUTOMATION - 6 - 08/11/2016 12:57
Changing a preset
To change the values of a preset press and using the / buttons select the
presets you wish to alter. Button takes you to the preset variables one by one
starting with Temperature, followed by depth, etc. To increase/decrease the value
of a variable use / . The button takes you a step back.
At any time you can run the altered preset without saving it, just press , which
takes you back to the list of preset and press again for filling to take place.
Saving a preset
Following the process above alter the variables of a preset and end the process by
scrolling to the Store preset line and using store the preset or using store the
preset and go back to the preset menu.
Temperature
38ºC
Presets
Preset One
Depth
75%
-
+
Disp: 1 0 drops
Disp: 2 0 drops
Disp: 3 35 drops
Disp: 6 0 drops
Disp: 4 0 drops
Disp: 5 0 drops
Disp: 12 0 drops
Store preset
-
+

COPYRIGHT 2016, UNIQUE AUTOMATION - 7 - 08/11/2016 12:57
Hand Shower
bathomatic with hand shower allows a hand or overhead shower to be controlled
from the BUI. Pressing the button will display a hand shower icon with
temperature and flow bars.
To start the shower with the temperature and flow displayed press and hold .
To increase/decrease the water temperature use / and to increase/decrease
the flow use / .
To turn the shower off press and the shower stops.
Exit by pressing the button. After 3 seconds of inactivity the BUI will display the
bathomatic status leaving the hand shower
Non active Active
Drain Operation
Closing the drain
BUI has a dedicate drain button. When the bath is empty and the drain is open
pressing the button will prompt a message “CLOSE DRAIN?” and to do this you
need to press the button.
Opening the drain
When the bath drain is closed with an empty bath or one containing water the
pressing of the button will prompt a message “OPEN DRAIN?”/“EMPTY BATH?”
and to do this you need to press the button. If there is water in the bath a
“DRAINING” message will appear
When bathomatic is filing →pressing of the button will prompt a message “STOP
FILLING?”, pressing the button will pause bathomatic and message “EMPTY
BATH?” will show. Pressing again will open the drain and “DRAINING” will
appear.

COPYRIGHT 2016, UNIQUE AUTOMATION - 8 - 08/11/2016 12:57
Main menu
Access the main menu by press the menu button
From within the main menu using / buttons select the option you wish to
change then use / to make the required change. Confirm the choice with
Main menu options:
CHILD LOCK Cleaning or child lock. To unlock the keypad press and
hold until the display lights up.
SET TEMP C/F Set temperature units Centigrade or Fahrenheit
ECO After a preset has been used, when enabled the true
bath depth before draining replaces the preset’s depth.
You need to leave the bath and allow few seconds prior
to draining
Eco or Auto Learning enables bathomatic to follow your
preferences and/or wait and draw the perfect bath every
time without wasting water or energy for heating it
SET SLEEP TIME 1 or 5 minutes
AUTO PAUSE Allows auto-pause when there is not enough hot water
T TO DEPTH WARNING Depth to T° warning. When this function is ON and the
device’s T° to depth calibration in the Service Menu has
been set a warning message will appear. When this
function is set to OFF there will be no message, but
there will be no guarantee of perfect water depth and
temperature delivery
TEMPERATURE PRIMING With this function ON bathomatic runs water in the bath
at maximum temperature with open drain. When the
water temperature running by the temperature sensor
reaches the desired temperature the drain closes and
normal filling proceeds. This function should be enabled
only when low bath depth are needed.
To minimise the environmental impact on the
“TEMPERATURE PRIMING”function it is recommended “T
TO DEPTH CALIBRATION”is carried out
SETUP MENU
CALIBRATION
DEPTH CALIBRATION
SET LEVEL –Allows for XXX% desired depth
SET 0% –Saves 0%
SET 100% –Saves 0%
TEMP CALIBRATION
TEMPERATURE OFFSET
T TO DEPTH CALIBRATION

COPYRIGHT 2016, UNIQUE AUTOMATION - 9 - 08/11/2016 12:57
THR CALIBRATION
MIN PUMP DEPTH –Depth at which recirculation pumps starts
PUMP ENABLED –Recirculation pump on/off during filling
SET DROP TIME - Perfume drop calibration (factory set for your
bathomatic)
MIN J PUMP DEPTH –Jet pump minimum depth
SELECT SENSOR
SERVICE NETWORK RESET
FACTORY RESET
DEMO MODE
SETTINGS SLAVE ADDRESS –a system can have up to two auxiliary (slave)
BUI
DEVICE TYPE –a system needs one master device to operate and
can have up to two slave devices
ABOUT Firmware version and service contact details
Exit by pressing the menu button . To move back a step press the menu button also.
Due to a delay in your hot water delivery system there are minimum bath depths for
certain temperatures
3
. If you are prompted with a message “DEPTH AND
TEMPERATURE MAY NOT BE ACHIEVED” this means that that you will need
higher depth for the chosen temperature.
3
Works only after T° to depth calibration has been run in the service menu.

COPYRIGHT 2016, UNIQUE AUTOMATION - 10 - 08/11/2016 12:57
Set Up Menu
Exit the service menu by pressing the menu button
Depth Calibration
Set Level
Bath tubs vary in depth and this function permits depths of more than 100% to be
set and run for depth calibration purposes. The depth value can go up to 255%. If
this depth is insufficient one needs to take interim 100% bath calibration steps until
the correct full bath depth is reached.
Filling does not stop automatically and can cause damage unless used correctly.
0% - bath calibration
The easiest and fastest way for 0% bath calibration is by pouring water into the bath
tub with the drain closed until the water fills the cavity of the waste completely and
becomes level with the bottom of the bath tub. When the water is level with the
bottom of the bath tub let it settle for 1 minute then select SET 0% in the SERVICE
MENU and press to store the value.
A:
2
Right arrow increments
the number
Main
Menu
Service
Menu
Service
Menu
Service
Menu
3
x
B:
0
C:
0
D:
7

COPYRIGHT 2016, UNIQUE AUTOMATION - 11 - 08/11/2016 12:57
It is often easier to draw more water than needed and adjust the depth by manually
lifting the drain until the water level is at 0%
Bath tub calibration should only be undertaken when the bath tub is in sight, and
you have easy access to the power switches supplying bathomatic and all
associated equipment. It is advisable that calibration is done prior to final
positioning of the bath panels/aprons. bathomatic can only operate reliably if it is
calibrated correctly
100% - bath calibration
Different bathtubs hold different amount of water and 100% calibration is
absolutely necessary to ensure correct operation. bathomatic can take any depth
to be 100% and you have to set it for your own bath. This should be set at around
20mm below the point of overflow. When bathtub is at 100% depth let the water
settle for 1 minute then select SET 100% in the SERVICE MENU and press to
store the value. Before you attempt to SET 100% you must first SET 0%
It is strongly recommended that 100% bath calibration is made below the point of
overflow.
If 100% - bath calibration is set at the point of overflowing, due to the
fluctuation of depth reading bathomatic may never reach 100%, thus it may
not stop filling should 100% fill is requested.
Bathomatic must be “PAUSED”for 0% or 100% bath calibration to take place
Temperature Offset
Allows the temperature reading from the bath to be offset. Must only be performed
by trained professionals or after consulting our technical stuff.
Temperature Calibration
Allows temperature sensor calibration. Must only be performed by trained
professionals or after consulting our technical stuff.
Reset
Factory reset the device to its factory settings. All customer data including presents
and calibration will be lost.

COPYRIGHT 2016, UNIQUE AUTOMATION - 12 - 08/11/2016 12:57
Trouble Shooting
bathomatic pauses on its own - If the water delivered to the bath starts to decrease
and the perfect bath cannot be delivered bathomatic will prompt you with “WATER
TEMPERATURE MAY NOT BE ACHIEVED” and bathomatic will automatically go
into pause
Maximum water temperature during filling is 55°C
Table of contents
Popular Control System manuals by other brands

Novatron
Novatron Xsite EASY 100022 installation manual

Elk
Elk ELK-M1EZ8 installation manual

Heavy Metal CNC
Heavy Metal CNC SX2.7 Installation instruction

Carrier
Carrier SYSTXCCSMS01-A installation instructions

Interroll
Interroll ZoneControl operating manual

Martin
Martin M6 Series Safety and installation guide

Siemens
Siemens SIMATIC PCS 7 manual

Lutron Electronics
Lutron Electronics Architrave GRAFIK5000 installation instructions

West Mountain Radio
West Mountain Radio TARGETuner operating manual

Lutron Electronics
Lutron Electronics RadioRA 2 Commisioning Checklist

Dimplex
Dimplex Free-E installation manual

Nidec
Nidec Control Techniques HVAC Drive H300 HMI... Installation and commissioning guide