manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Unit
  6. •
  7. Measuring Instrument
  8. •
  9. Unit UT-8802E User manual

Unit UT-8802E User manual

Other Unit Measuring Instrument manuals

Unit UT108 User manual

Unit

Unit UT108 User manual

Unit UTE9800+ Series User manual

Unit

Unit UTE9800+ Series User manual

Unit MIE0149 User manual

Unit

Unit MIE0149 User manual

Unit UT312 User manual

Unit

Unit UT312 User manual

Unit UT685B User manual

Unit

Unit UT685B User manual

Unit A37 Operating manual

Unit

Unit A37 Operating manual

Unit LCR-1000 series User manual

Unit

Unit LCR-1000 series User manual

Unit LM50G User manual

Unit

Unit LM50G User manual

Unit UT371 User manual

Unit

Unit UT371 User manual

Unit UT383 User manual

Unit

Unit UT383 User manual

Unit UT241 User manual

Unit

Unit UT241 User manual

Unit UT310 Series User manual

Unit

Unit UT310 Series User manual

Unit MSO3000E Series User manual

Unit

Unit MSO3000E Series User manual

Unit UT255A User manual

Unit

Unit UT255A User manual

Unit UT181A User manual

Unit

Unit UT181A User manual

Unit UT267B User manual

Unit

Unit UT267B User manual

Unit UT620C User manual

Unit

Unit UT620C User manual

Unit UTS1000B Series User manual

Unit

Unit UTS1000B Series User manual

Unit UTi320V User manual

Unit

Unit UTi320V User manual

Unit UT382 User manual

Unit

Unit UT382 User manual

Unit UTS3000B Series User manual

Unit

Unit UTS3000B Series User manual

Unit UT585 User manual

Unit

Unit UT585 User manual

Unit UT351 User manual

Unit

Unit UT351 User manual

Unit UTE9802 User manual

Unit

Unit UTE9802 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User Manual
Code: UT-8802E
LABORATORY METER UT-8802E UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-8802E 1/5
Warning!
Please read the user manual included in this work as it contains important information related with safety of installation and use of
the device.
Only persons who read the user manual may use the device.
The user manual must be kept because it may be required in the future. The device is to be used exclusively for purposes specified
in this user manual.
The device must be unpacked prior to starting-up. After removing the packaging make sure the device is in working order.
If the product has defects, it should not be used until it is repaired.
The product is intended for use at home and commercial use and may not be used for other than intended use.
The manufacturer is not liable for damages resulting from not adhering to the rules contained in the user manual, therefore, we
recommend to follow the aforementioned safety rules for operation and maintenance of the device. In this way you will ensure
yourself safety and avoid causing damage to the device.
The manufacturer and the supplier are not liable for losses or damages arising out of the product, including financial or intangible
losses, loss of profits, income, data, pleasure from use of the product or other products related with it - indirect, incidental or
consequential loss or damage. The above provisions apply whether the loss or damage concerns:
1. Deterioration of quality or the lack of operation of the products or products related with it due to damage as well as the lack of
access to the product when it is undergoing repair, which results in stoppage the loss of user's time or a break in business activity;
2. Improper results of operation of the product or products related with it;
3. It applies to losses and damages according to any legal category, including negligence and other losses, termination of a
contract, expressed or implied guarantee and strict liability (even if the manufacturer or the supplier was notified about the
possibility of occurrence of such damages).
Safety measures:
Particular attention at designing was directed to quality standards of the device where ensuring safety of operation is the most
important factor.
The device must be secured against contact with caustic, staining and viscous fluids.
The device was designed in such a way that it restarts operation when power supply is restored after a break.
Turn off the device before transporting it.
Prior to connecting the device to a power source check whether the supplied voltage is consistent with rated voltage specified in
the user manual.
Attention! We recommend using protections to further protect the device from possible overvoltages in installations.
Surge protectors are effective protection against accidental pass to the device voltages higher than the rated. Damages
caused by pass the voltages higher than specified in manual, are not under warranty.
Proper product disposal:
A marking of a crossed out waste bin indicates that the product may not be disposed together with other household waste in the
entire EU. To avoid possible damage to the natural environment of health due to uncontrolled waste disposal, therefore, it should be
handed over for recycling, propagating in this way sustainable use of natural resources.
To return a worn-out product, use a collection and disposal system of this type of equipment or contact a seller from whom it was
purchased. He will then be recycled in an environmentally-friendly way.
It is forbidden to use the device in case its power cord or plug is damaged, the device works incorrectly, was damaged or dropped.
A damaged power cord or plug must be replaced with new ones by the manufacturer, personnel of service centre or a person with
relevant qualifications in order to avoid the risk of electric shock. We do not recommend repairing the device on one's own for
safety reasons.
The device is not intended for operation by persons (including children) with limited physical, sensory or mental capabilities as well
as persons inexperienced in operation or not competent to operate of such device, unless the operation is supervised by a person
responsible for their safety or in line with instructions for use provided by such person.
It is forbidden to touch the plug with wet hands! Pull the plug, never the cable, to pull out the plug from a socket.
The device is to be used exclusively according to its use described in this manual. Use of accessories not recommended by the
manufacturer of the device may cause fire, electric shock or injuries.
Marking of a lightning inside a equilateral triangle signifies presence of dangerous voltage, contained under the cover of the device.
It may be dangerous for user's life and health.
User Manual
Code: UT-8802E
LABORATORY METER UT-8802E UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-8802E 2/5
The UT-8802E is a digital laboratory meter used to
measure: voltage, current, resistance, capacity,
frequency, and to check the correct operation of
diodes.
DC voltage measurement:
• 200 mV ± (0.1% + 5) @ 0.01 mV,
• 2 V ± (0.1% + 3) @ 0.1 mV,
• 20 V ± (0.1% + 3) @ 0.001 V,
• 200 V ± (0.1% + 3) @ 0.01 V,
• 1000 V ± (0.2% + 5) @ 0.1 V
AC voltage measurement:
• 2 V @ 100 µV ± (0.5% + 20) @ 40 Hz ... 1 kHz
• 20 V @ 1 mV ± (0.5% + 20) @ 40 Hz ... 1 kHz
• 200 V @ 10 mV ± (0.5% + 20) @ 40 Hz ... 1 kHz
• 750 V @ 0.1 V ± (0.8% + 40) @ 40 Hz ... 1 kHz
DC current measurement:
• 200 µA ± (0.5% + 20) @ 10 nA,
• 2 mA ± (0.5% + 20) @ 100 nA,
• 20 mA ± (0.5% + 20) @ 1 µA,
• 200 mA ± (0.5% + 20) @ 10 µA,
• 20 A ± (1.5% + 40) @ 1 mA
AC current measurement:
• 2 mA @ 0.1 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz
• 20 mA @ 1 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz
• 200 mA @ 10 µA ± (0.8% + 40) @ 45 Hz ... 400 Hz
• 20 A @ 1 mA ± (2% + 40) @ 45 Hz ... 400 Hz
Resistance measurement:
• 200 Ω ± (0.5% + 10) + test leads resistance @ 0.01 Ω,
• 2 kΩ ± (0.5% + 10) @ 0.1 Ω,
• 20 kΩ ± (0.5% + 10) @ 1 Ω,
• 200 kΩ ± (0.5% + 10) @ 10 Ω,
• 2 MΩ ± (0.5% + 10) @ 100 Ω,
• 200 MΩ @ 1 kΩ
Capacitance measurement:
• 20 nF ± (2.5% + 10) @ 1 pF,
• 200 nF ± (1.5% + 10) @ 10 pF,
• 2 µF ± (1.5% + 10) @ 100 pF,
• 20 µF ± (1.5% + 10) @ 1 nF,
• 200 µF ± (1.5% + 10) @ 10 nF,
• 2 mF ± (1.5% + 10) @ 100 nF,
• 20 mF ± (10% + 10) @ 1 µF,
• 100 mF @ 10 µF
Inductance measurement:
User Manual
Code: UT-8802E
LABORATORY METER UT-8802E UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-8802E 3/5
Frequency measurement:
• 200 Hz ± (1% + 5) @ 0.01 Hz,
• 2 kHz ± (1% + 5) @ 0.1 Hz,
• 20 kHz ± (1% + 5) @ 1 Hz,
• 200 kHz ± (1% + 5) @ 10 Hz,
• 2 MHz ± (1% + 5) @ 100 Hz,
• 10 MHz ± (1% + 5) @ 1 kHz,
• 5 % ... 99 % ± (1.5% + 2) @ 10 Hz ... 10 kHz
Temperature measurement:
Automatic change of measuring ranges:
hFE:
Diode test:
Sound signal of the continuity test:
Checking TTL logic states:
RS-232:
USB:
Main features:
• Very high accuracy of measurements
• EBTN display
• REL - relative measurement mode
• Writing the value MAX / MIN
• Hold - stopping the meter reading
• Port USB
• Aesthetic and solid construction
Power supply: 110 V AC / 120 V AC / 220 V AC / 240 V AC - selectable by switch
Weight: 3.43 kg
Dimensions: 320 x 265 x 110 mm
Manufacturer / Brand: UNI-T
Guarantee: 2 years
Front panel:
User Manual
Code: UT-8802E
LABORATORY METER UT-8802E UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-8802E 4/5
Rear view:
Included, among others measuring adapter:
User Manual
Code: UT-8802E
LABORATORY METER UT-8802E UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-8802E 5/5
In the kit: