Unit UT209 User manual

Model UT209
OPERATING MANUAL

Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
The Effectiveness of Functional Buttons
Display Symbols
Measurement Operation
A. DC/AC Voltage Measurement
B. Measuring Resistance
C. Testing Diodes
D. Testing for Continuity
E. Frequency Measurement
F. DC Current Measurement
3
4
5
6
9
10
11
13
14
17
17
19
21
23
25
27
Model UT209: OPERATING MANUAL
1

Title Page
30
32
33
33
34
35
35
36
37
38
38
39
40
40
41
41
42
G. AC Current Measurement
Sleep Mode
Specifications
A. General Specifications
B. Environmental Requirements
Accuracy Specifications
A. DC Voltage
B. AC Voltage
C. Resistance
D. Diode Test
E. Continuity Test
F. Frequency
G. DC Current
H. AC Current
Maintenance
A. General Service
B. Replacing the Battery
Model UT209: OPERATING MANUAL
2

Overview
This Operating Manual covers information on safety and cautions. Please read the
relevant information carefully and observe all the Warnings and Notes strictly.
Warning
To avoid electric shock or personal injury, read the “Safety Information” and
“Rules for Safe Operation” carefully before using the Meter.
Digital Clamp Multimeter Model UT209 (hereafter referred to as “the Meter”) are 3
3/4 digits with steady operations, fashionable structure and highly reliable measuring
instrument. The Meter uses large scale of integrated circuit with double integrated
A/D converter as its core and has full range overload protection.
The Meter can measure AC/DC Voltage, AC/DC Current, Frequency, Resistance,
Diodes, Continuity and etc.
Model UT209: OPERATING MANUAL
3

Item Description Qty
1
2
3
4
English Operating Manual
Test Lead
Tool Box
9V Battery (NEDA1604A or 6LF22)
1 piece
1 pair
1 piece
1 piece
Unpacking Inspection
Open the package case and take out the Meter. Check the following items carefully
to see any missing or damaged part:
In the event you find any missing or damage, please contact your dealer immediately.
Model UT209: OPERATING MANUAL
4

Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage
category (CAT. II 600V, CAT. III 300V) and double insulation.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient
overvoltages than CAT. III.
CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than
CAT. IV
Use the Meter only as specified in this operating manual, otherwise the protection
provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to the
user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention to.
International electrical symbols used on the Meter and in this Operating Manual are
explained on page 9.
Model UT209: OPERATING MANUAL
5

Rules For Safe Operation
To avoid possible electric shock or personal injury, and to avoid possible
damage to the Meter or to the equipment under test, adhere to the following
rules:
Warning
Before using the Meter inspect the case. Do not use the Meter if it is
damaged or the case (or part of the case) is removed. Look for cracks or
missing plastic. Pay attention to the insulation around the connectors.
Inspect the test leads for damaged insulation or exposed metal. Check the
test leads for continuity. Replace damaged test leads with identical model
number or electrical specifications before using the Meter.
Do not apply more that the rated voltage, as marked on the Meter , between
the terminals or between any terminal and grounding.
When measurement has been completed, disconnect the connection between
the test leads and the circuit under test, remove the testing leads away
from the input terminals of the Meter and turn the Meter power off.
The rotary switch should be placed in the right position and no any
Model UT209: OPERATING MANUAL
6

changeover of range shall be made during measurement is conducted to
prevent damage of the Meter.
Do not carry out the measurement when the Meter’s back case and battery
compartment are not closed to avoid electric shock.
Do not input higher than 600V between the two Meter’s input terminal to
avoid electric shock and damages to the Meter.
When the Meter working at an effective voltage over 70V in DC or 33V rms
in AC, special care should be taken for there is danger of electric shock.
Use the proper terminals, function, and range for your measurements.
Do not use or store the Meter in an environment of high temperature,
humidity, explosive, inflammable and strong magnetic field. The performance
of the Meter may deteriorate after dampened.
When using the test leads, keep your fingers behind the finger guards.
To avoid electric shock, do not touch the bare wires, connectors, unused
input terminals or the circuit under testing during measurement.
Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance, continuity and diode.
Replace the battery as soon as the battery indicator appears. With a
low battery, the Meter might produce false readings that can lead to electric
shock and personal injury.
Model UT209: OPERATING MANUAL
7

When servicing the Meter, use only the same model number or identical
electrical specifications replacement parts.
The internal circuit of the Meter shall not be altered at will to avoid damage
of the Meter and any accident.
Soft cloth and mild detergent should be used to clean the surface of the
Meter when servicing. No abrasive and solvent should be used to prevent
the surface of the Meter from corrosion, damage and accident.
The Meter is suitable for indoor use.
Turn the Meter off when it is not in use and take out the battery when not
using for a long time.
Constantly check the battery as it may leak when it has been using for
some time, replace the battery as soon as leaking appears. A leaking
battery will damage the Meter.
Model UT209: OPERATING MANUAL
8

International Electrical Symbols
AC (Alternating Current)
DC (Direct Current)
AC or DC
Grounding
Double Insulated
Warning. Refer to the Operating Manual
Deficiency of Built-In Battery
Continuity Test
Diode
Danger of High Voltage
Conforms to Standards of European Union
Model UT209: OPERATING MANUAL
9

Figure 1
The Meter Structure (see figure 1)
Hand Guards: to protect user’s hand
from touching the dangerous area.
Trigger: press the lever to open the
transformer jaws. When the pressure
on the lever is released, the jaws will
close.
Functional Buttons
Input Terminals
LCD Display
Rotary Switch
Transformer Jaw: designed to pick up
theAC and DC current flowing through
the conductor. It could transfer current
to voltage. The tested conductor must
vertically go through the Jaw center.
1.
2.
3.
4.
5.
6.
7.
Model UT209: OPERATING MANUAL
10

Press SELECT button to select the alternate functions including
V , and
Button Operation Performed
SELECT
PMAX/PMIN
Press HOLD to enter the Hold mode in any mode, the Meter
beeps.
Press HOLD again to exit the Hold mode to return to measurement
mode, the Meter beeps.
HOLD
Functional Buttons
Below table indicated for information about the functional button operations.
Press and hold for 2 seconds to enter that function internal
calibration.
Press the button once to start recording of maximum peak value.
Press the button again to start recording of minimum peak value.
Press and hold for one second to exit PMAX/PMIN mode.
Press once to turn the display backlight on.
It will automatically off after around 15 seconds.
Model UT209: OPERATING MANUAL
11

Button Operation Performed
HOLD
Hz
ZERO Press ZERO to display the present value as stored value and
display zero. After that, all the measurement result displayed
will automatically subtract the stored value.
Press ZERO again to display the stored value.
Press and hold ZERO to exit and back to normal operation.
Turn the rotary switch or press SELECT button can also exit
Hold mode.
Press HOLD button for 2 seconds when turning on the Meter to
display full icon.
When the Meter is at V, A and A , press the button to
measure frequency. But the frequency readings obtained from
these ranges are only for reference,
Model UT209: OPERATING MANUAL
12

SELECT MAX/MIN HOLD Hz ZERO
%Hz
44A
1000A
40A
1000A N/A
N/A
N/A
N/A
N/A
N/A
N/A
Rotary Switch
Positions
V
Functional Buttons
N/A
N/A
The Effectiveness of Functional Buttons
Not every functional buttons can be used on every rotary switch positions. Below
table describe which functional buttons can be used on which rotary switch positions
Model UT209: OPERATING MANUAL
13

Figure 2
Display Symbols (see figure 2)
Model UT209: OPERATING MANUAL
14

Number Symbol Meaning
1
2
3
4
5
6
7
8
9
10
11
Hz,
kHz,
MHz
,
k ,
M
PMAX
PMIN
ZERO
Hz: Hertz. The unit of frequency.
KHz: Kilohertz. 1 x 103or 1000 hertz.
MHz: Meghertz. 1 x 106or1,000,000 hertz.
: Ohm. The unit of resistance.
k :Kilohm. 1×103 or 1000 ohms
M :Megohm. 1×106 or 1,000,000 ohms
Maximum peak reading displayed
Minimum peak reading displayed
Indicator for relative value zeroing
Data hold is active
The Meter is in the auto range mode in which the
Meter automatically selects the range with the best
resolution.
True RMS indicator
Indicator for AC voltage or current
Indicates negative reading
Indicator for DC voltage
H
AUTO
RMS
AC
DC
Model UT209: OPERATING MANUAL
15

Number Symbol Meaning
12
13
14
15
16
17
18
19
The battery is low.
Warning: To avoid false readings, which
could lead to possible electric shock or
personal injury, replace the battery as soon as
the battery indicator appears.
Sleep mode is on
Analogue bar graph ruler
Analogue Bar Graph
Test of diode
The continuity buzzer is on
Amperes (amps). The unit of current.
Volts. The unit of voltage.
mV: Millivolt. 1×10-3 or 0.001 volts
A
mV, V
Model UT209: OPERATING MANUAL
16

A.DC/AC Voltage Measurement (see figure 3)
To avoid harms to you or damages to the Meter from eletric shock, do not
attempt to measure voltages higher than 600V AC/DC, although readings may
be obtained.
The DC Voltage ranges are:
400mV, 4V, 40V, 400V and 600V
The AC Voltage ranges are:
400mV, 4V, 40V, 400V and 600V
Red Black Red Black
Measurement Operation
Figure 3
Warning
Model UT209: OPERATING MANUAL
17

To measure DC/AC voltages, connect the Meter as follows:
Insert the red test lead into the V Hz terminal and black test lead into the COM
terminal.
Set the rotary switch to V . DC mesaurement mode and auto ranging is a default.
Press SELECT to switch to AC measurement mode.
Press Hz button to measure frequency , but the frequency readings obtained
from this range is only for reference.
Connect the test leads across with the object being measured.
The measured value shows on the display.
1.
2.
3.
4.
Note
When DC/AC voltage measurement has been completed, disconnect the connection
between the testing leads and the circuit under test and remove testing leads
from the input terminals.
Model UT209: OPERATING MANUAL
18

B.Measuring Resistance (see figure 4)
To avoid damages to the Meter or to the devices
under test, disconnect circuit power and
discharge all the high-voltage capacitors before
measuring resistance.
The resistance ranges are:
400 , 4k , 40k , 400k and 40M
To measure resistance, connect the Meter as
follows:
Insert the red test lead into the V Hz terminal
and black test lead into the COM terminal.
Set the rotary switch to Resistance
measurement is a default or press SELECT
to switch to measurement mode.
1.
2.
Red Black
Figure 4
Warning
Model UT209: OPERATING MANUAL
19
Table of contents
Other Unit Multimeter manuals