manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Unit
  6. •
  7. Multimeter
  8. •
  9. Unit UT70A User manual

Unit UT70A User manual

Other manuals for UT70A

1

Other Unit Multimeter manuals

Unit UT513 User manual

Unit

Unit UT513 User manual

Unit UT58E User manual

Unit

Unit UT58E User manual

Unit UT58E User manual

Unit

Unit UT58E User manual

Unit MIE0141 User manual

Unit

Unit MIE0141 User manual

Unit UT803 User manual

Unit

Unit UT803 User manual

Unit UT106 User manual

Unit

Unit UT106 User manual

Unit UT205A User manual

Unit

Unit UT205A User manual

Unit UT90A User manual

Unit

Unit UT90A User manual

Unit UT151A User manual

Unit

Unit UT151A User manual

Unit UT204A User manual

Unit

Unit UT204A User manual

Unit UT2000 series User manual

Unit

Unit UT2000 series User manual

Unit UT61 series User manual

Unit

Unit UT61 series User manual

Unit UT39A User manual

Unit

Unit UT39A User manual

Unit UT50D User manual

Unit

Unit UT50D User manual

Unit UT60H User manual

Unit

Unit UT60H User manual

Unit UT181A User manual

Unit

Unit UT181A User manual

Unit UT208A User manual

Unit

Unit UT208A User manual

Unit UT71 User manual

Unit

Unit UT71 User manual

Unit UT207A User manual

Unit

Unit UT207A User manual

Unit UT81B User manual

Unit

Unit UT81B User manual

Unit UT58A User manual

Unit

Unit UT58A User manual

Unit UT120A User manual

Unit

Unit UT120A User manual

Unit UT70D User manual

Unit

Unit UT70D User manual

Unit UT-33D+ User manual

Unit

Unit UT-33D+ User manual

Popular Multimeter manuals by other brands

Fluke 106 user manual

Fluke

Fluke 106 user manual

VAR DV-71600 manual

VAR

VAR DV-71600 manual

Agilent Technologies 34420A user guide

Agilent Technologies

Agilent Technologies 34420A user guide

Fluke 83 user manual

Fluke

Fluke 83 user manual

Hameg HM 8012 manual

Hameg

Hameg HM 8012 manual

Mastech MY70 Operation manual

Mastech

Mastech MY70 Operation manual

Steren MUL-300 user manual

Steren

Steren MUL-300 user manual

Somogyi Elektronic home SMA 92 instruction manual

Somogyi Elektronic

Somogyi Elektronic home SMA 92 instruction manual

Gossen MetraWatt METRAmax 6 operating instructions

Gossen MetraWatt

Gossen MetraWatt METRAmax 6 operating instructions

PeakTech 4000 Procedure of calibration

PeakTech

PeakTech 4000 Procedure of calibration

YOKOGAWA 90050B user manual

YOKOGAWA

YOKOGAWA 90050B user manual

Fluke 8846A Programmer's manual

Fluke

Fluke 8846A Programmer's manual

Tempo Communications MM200 instruction manual

Tempo Communications

Tempo Communications MM200 instruction manual

APPA 607 user manual

APPA

APPA 607 user manual

Elenco Electronics CM-1555 operating instructions

Elenco Electronics

Elenco Electronics CM-1555 operating instructions

Mastech MS8238C user manual

Mastech

Mastech MS8238C user manual

SDAR 830A, 830B, 830D, 830C user manual

SDAR

SDAR 830A, 830B, 830D, 830C user manual

RS PRO RS-9519BT instruction manual

RS PRO

RS PRO RS-9519BT instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User Manual
Code: UT-70A
UNIVERSAL METER UT-70A UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2022-01-15 UT-70A 1/4
Warning!
Please read the user manual included in this work as it contains important information related with safety of installation and use of
the device.
Only persons who read the user manual may use the device.
The user manual must be kept because it may be required in the future. The device is to be used exclusively for purposes specified
in this user manual.
The device must be unpacked prior to starting-up. After removing the packaging make sure the device is in working order.
If the product has defects, it should not be used until it is repaired.
The product is intended for use at home and commercial use and may not be used for other than intended use.
The manufacturer is not liable for damages resulting from not adhering to the rules contained in the user manual, therefore, we
recommend to follow the aforementioned safety rules for operation and maintenance of the device. In this way you will ensure
yourself safety and avoid causing damage to the device.
The manufacturer and the supplier are not liable for losses or damages arising out of the product, including financial or intangible
losses, loss of profits, income, data, pleasure from use of the product or other products related with it - indirect, incidental or
consequential loss or damage. The above provisions apply whether the loss or damage concerns:
1. Deterioration of quality or the lack of operation of the products or products related with it due to damage as well as the lack of
access to the product when it is undergoing repair, which results in stoppage the loss of user's time or a break in business activity;
2. Improper results of operation of the product or products related with it;
3. It applies to losses and damages according to any legal category, including negligence and other losses, termination of a
contract, expressed or implied guarantee and strict liability (even if the manufacturer or the supplier was notified about the
possibility of occurrence of such damages).
Safety measures:
Particular attention at designing was directed to quality standards of the device where ensuring safety of operation is the most
important factor.
The device must be secured against contact with caustic, staining and viscous fluids.
The device was designed in such a way that it restarts operation when power supply is restored after a break.
Turn off the device before transporting it.
Prior to connecting the device to a power source check whether the supplied voltage is consistent with rated voltage specified in
the user manual.
Attention! We recommend using protections to further protect the device from possible overvoltages in installations.
Surge protectors are effective protection against accidental pass to the device voltages higher than the rated. Damages
caused by pass the voltages higher than specified in manual, are not under warranty.
Proper product disposal:
A marking of a crossed out waste bin indicates that the product may not be disposed together with other household waste in the
entire EU. To avoid possible damage to the natural environment of health due to uncontrolled waste disposal, therefore, it should be
handed over for recycling, propagating in this way sustainable use of natural resources.
To return a worn-out product, use a collection and disposal system of this type of equipment or contact a seller from whom it was
purchased. He will then be recycled in an environmentally-friendly way.
It is forbidden to use the device in case its power cord or plug is damaged, the device works incorrectly, was damaged or dropped.
A damaged power cord or plug must be replaced with new ones by the manufacturer, personnel of service centre or a person with
relevant qualifications in order to avoid the risk of electric shock. We do not recommend repairing the device on one's own for
safety reasons.
The device is not intended for operation by persons (including children) with limited physical, sensory or mental capabilities as well
as persons inexperienced in operation or not competent to operate of such device, unless the operation is supervised by a person
responsible for their safety or in line with instructions for use provided by such person.
It is forbidden to touch the plug with wet hands! Pull the plug, never the cable, to pull out the plug from a socket.
The device is to be used exclusively according to its use described in this manual. Use of accessories not recommended by the
manufacturer of the device may cause fire, electric shock or injuries.
Marking of a lightning inside a equilateral triangle signifies presence of dangerous voltage, contained under the cover of the device.
It may be dangerous for user's life and health.
User Manual
Code: UT-70A
UNIVERSAL METER UT-70A UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2022-01-15 UT-70A 2/4
The UT-70A is a universal digital meter used to measure:
voltage, current, resistance, inductance, capacitance,
frequency, hFE, temperature and checking the correctness
of diodes operation.
DC voltage measurement:
200 mV ± (0.5% + 1) @ 100 µV ,
2 V ± (0.5% + 1) @ 1 mV ,
20 V ± (0.5% + 1) @ 10 mV ,
200 V ± (0.5% + 1) @ 100 mV ,
1000 V ± (0.8% + 2) @ 1 V
AC voltage measurement:
200 mV ± (1.2% + 3) @ 100 µV ,
2 V ± (0.8% + 3) @ 1 mV ,
20 V ± (0.8% + 3) @ 10 mV ,
200 V ± (0.8% + 3) @ 100 mV ,
750 V ± (1.2% + 3) @ 1 V
DC current measurement:
20 µA ± (0.8% + 1) @ 0.01 µA ,
2 mA ± (0.8% + 1) @ 1 µA ,
200 mA ± (1.5% + 1) @ 0.1 mA ,
10 A ± (2.0% + 5) @ 10 mA
AC current measurement:
20 µA ± (1.0% + 3) @ 0.01 µA ,
2 mA ± (1.0% + 3) @ 1 µA ,
200 mA ± (1.8% + 3) @ 0.1 mA ,
10 A ± (3.0% + 7) @ 10 mA
Resistance measurement:
200 Ω ± (0.8% + 3) @ 0.1 Ω ,
2 kΩ ± (0.8% + 1) @ 1 Ω ,
20 kΩ ± (0.8% + 1) @ 10 Ω ,
200 kΩ ± (0.8% + 1) @ 100 Ω ,
2 MΩ ± (0.8% + 1) @ 1 kΩ ,
20 MΩ ± (1.0% + 5) @ 10 kΩ ,
2000 MΩ ± (5.0% + 10) @ 1 MΩ
Capacitance measurement:
20 nF ± (2.5% + 5) @ 10 pF ,
200 nF ± (2.5% + 5) @ 100 pF ,
2 µF ± (2.5% + 5) @ 1 nF ,
100 µF ± (5.0% + 4) @ 100 nF
User Manual
Code: UT-70A
UNIVERSAL METER UT-70A UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2022-01-15 UT-70A 3/4
Inductance measurement:
2 mH ± (2.0% + 10) @ 1 µH ,
20 mH ± (2.0% + 10) @ 10 µH ,
200 mH ± (2.0% + 10) @ 0.1 mH ,
20 H ± (3.0% + 10) @ 10 mH
Frequency measurement: 2 kHz ... 10 MHz ± (0.1% + 3) @ 1 Hz (automatic range change)
Temperature measurement:
• °C
-40 ... 0 °C ± (3% + 4) @ 1 °C
0 ... 400 °C ± (1% + 3) @ 1 °C
400 ... 1000 °C ± (2% + 10) @ 1 °C,
• °F
-40 ... 32 °F ± (3% + 4) @ 1 °F
32 ... 752 °F ± (1% + 4) @ 1 °F
752 ... 1832 °F ± 2.5% @ 1 °F
hFE:
Diode test:
Sound signal of the continuity test:
Checking TTL logic states:
RS-232:
Main features: • Large, readable LCD display with backlight
• Aesthetic and solid construction
Power supply: 9V, type 6F22 battery - included
Dimensions: 205 x 101 x 60 mm
Manufacturer / Brand: UNI-T
Guarantee: 2 years
User Manual
Code: UT-70A
UNIVERSAL METER UT-70A UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2022-01-15 UT-70A 4/4
In the kit: