United Technologies interlogix ACL805SUW-RDPX Assembly instructions

© 2017 UTC Fire & Security. All rights reserved. 1 / 6 2017-10-13
ACL805SUW-RDPX
Reader Installation Sheet
EN
Surface Mount Keypad with EM/CASI/HID Proximity reader
Figure 1: Angled front view
Mounting
Figure 2: Mounting instructions
3(3 x 30mm)
1 (M3 x 6mm)
Description
The ACL805SUW-RDPX is a Multiprotocol
digital keypad and proximity reader for
access control applications with backlit
keys and a selectable output protocol.
These surface mount readers includes a
buzzer and a tri-color LED for state
indication (access granted, access denied
or idle).
The ACL805SUW-RDPX is capable of
reading Casi Rusco, EM and HID.
compatible cards/fobs (125 kHz).

© 2017 UTC Fire & Security. All rights reserved. 2 / 6 2017-10-13
Wiring
Figure 3: Wiring instructions
Specifications
Operating voltage
9 to 14 VDC
Current consumption
110 mA at 12 VDC
Interface Proximity Reader
Wiegand according to the card type
Wiegand 32 bit : EM410x Cards
Wiegand 40 bit : Casi-Rusco
Automatic Wiegand - HID Cards
EM410x
Wiegand 32 description
32 data bits
Pulse width: 100 µs
Pause: 1 ms
Wiegand for EM410x Cards
Casi-Rusco
Wiegand 40 description
even parity + 38 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 1 to 19
P2 = odd parity calculated over the bits 0 to 39
Wiegand for Casi-Rusco cards
HID
Wiegand 26 –37 bit
Automatic Wiegand according to the HID card type
Interface Keypad
Wiegand 26, 30, 34, 40, 42, 58 bit,
8 bit per key, 6 bit per key, 4 bit per key
Wiegand 26 description
even parity + 24 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 13
P2 = odd parity calculated over the bits 14 to 25
Wiegand 30 description
even parity + 28 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 15
P2 = odd parity calculated over the bits 16 to 29
Wiegand 34 description
even parity + 32 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 17
P2 = odd parity calculated over the bits 18 to 33
1
tamp
Tamper
2
tamp
Tamper
3
LG-
LED Green minus
4
LR-
LED Red minus
5
GND
Ground
6
+12 V
9 to 14 VDC
7
D0
Data 0
8
D1
Data 1
gray
blue
yellow
orange
black
red
green
white
1
2
3
4
5
6
7
8
LR-
D1
D0
tamp
GND
+12 V
LG-
tamp

© 2017 UTC Fire & Security. All rights reserved. 3 / 6 2017-10-13
Wiegand 40 description
even parity + 38 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 20
P2 = odd parity calculated over the bits 21 to 39
Wiegand 42 description
even parity + 40 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 21
P2 = odd parity calculated over the bits 22 to 41
Wiegand 58 description
even parity + 56 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 29
P2 = odd parity calculated over the bits 30 to 57
Wiegand 8 bit per key description
8 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
Wiegand 6 bit per key description
6 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
Wiegand 4 bit per key description
4 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
PIN Code length
1 to 8 digits
LED control
Yes, by wires
LED
Green : Externally controlled
Red : Externally controlled
Orange : Idle, Key press and Menu
Tamper
Yes
Cable distance
50 m according to Wiegand standard
Panel connection
Cable, 1 m
Material of design housing
ABS
Dimensions (W x H x D)
100 x 94 x 30 mm
Operating Temperature
Relative humidity
−20 to +50°C
0 to 95% noncondensing
IP rating
IP65
Color
-S = Silver, -G = Grey
Weight (shipping)
Weight (product)
550 g
250 g
DIP switch settings –Proximity Reader
1.Backlight in idle mode ON/OFF
2.Buzzer on card read ON/OFF
3. not used
4.Enable HID (ON_OFF)
5. Enable EM or CASI (ON_OFF)
6. Select EM or CASI
(ON-EM; OFF-Casi Rusco)

© 2017 UTC Fire & Security. All rights reserved. 4 / 6 2017-10-13
Card type selection
HID only HID and EM HID and Casi Casi only EM only
Settings in TruPortal Software
Settings in pcProxConfig Software
Go to System Administration/Card Formats. Select the Wiegand format that corresponds to the card type:
- 32 bit 14443 cascade 1 for EM Cards
- 40 bit CASI 4002 for Casi-Rusco Cards
- The HID formats available for HID Cards
Select Casi Rusco (GE Security, UTC) or EM 410x or some of the available HID formats as card type.
Use these settings in the pcProx Config Software when reading the card via the TP-RDR-LRN desktop Reader.
EM
Casi Rusco

© 2017 UTC Fire & Security. All rights reserved. 5 / 6 2017-10-13
Keypad programming flowchart
Entering Menu is always done with B(3 s) + 000000 if the Master Code is not changed.
Submenu 1 - Change Master Code. The Master Code must be 6 digits. After enrolling new Master Code the
ACL875W automatically exits the Menu and the new master code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand. The Wiegand selected must be the same as the controller’s Wiegand Input
where the ACL805SUW-RDPX Keypad is being connected. Example: If you use a controller that recognizes Wiegand
34 bit, then enter the menu of ACL805SUW-RDPX, press 2, then press 3.
Submenu 3 - Select Output Protocol. Keypad have the following outputs:
3-1 Single Wiegand - Keypad will send code in Wiegand format
3-3 Clock & Data - Keypad will send the code in Clock & Data format
3-5 8 bit per key - Each key press will be sent as 8 bit data immediately. Key press will be sent as following table:
3-6 6 bit per key - Each key press will be sent as 6 bit data immediately.
3-7 4 bit per key - Each key press will be sent as 4 bit data immediately.
Submenu 4 - PIN Code Length. If “0” is selected, then any PIN Code with any length can be sent, but the PIN Code is
typed with “A” for confirmation (ex. 123 + A). If 1 to 8 is selected the PIN Code length is set by the number selected.
Submenu 6 - Presets. The Presets are set of preprogrammed parameters for easy programming.
6-1 “Wiegand 26 bit Normal” - Type: Wiegand 26 bit; Output: Single Wiegand; PIN Length: 4 digits;
6-2 “Wiegand 34 bit Normal” - Type: Wiegand 34 bit; Output: Single Wiegand; PIN Length: 4 digits;
Submenu 7 - Site Code Length. Set the code length sent to Host. Default is “0”. To be used only in specific cases.
Submenu 8 - Enter Site Code. Put the site code always in 5 digit format (ex. 00170).
Key
0
1
2
3
4
5
6
7
8
9
A
B
Wiegand output
240
225
210
195
180
165
150
135
120
105
90
75

© 2017 UTC Fire & Security. All rights reserved. 6 / 6 2017-10-13
Submenu 9 - Turns ON/OFF the backlight in idle mode, buzzer on key press, parity bit.
Reset Master Code
1. Disconnect Power
2. Press and hold “A” and reconnect Power.
3. Hold the “A” Key for at least 3 seconds.
Default Master Code: 000000
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Version
This document applies to ACL805SUW-RDPX hardware
Certification and Regulatory
information
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive
2014/53/EU. In addition it complies with RoHS directive EN50581:2012
Contact information
https://firesecurityproducts.comor www.interlogix.com
Product Warnings
and Disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY
PROFESSIONAL. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON
OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY
TRAINED OR EXPERIENCED TO CORRECTLY INSTALL SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please check
https://www.utcfssecurityproducts.eu/productwarning/ or scan the following code:
Table of contents
Popular RFID System manuals by other brands

Omron
Omron V680S Series user manual

EMS
EMS COBALT C0405 Series Operator's manual

Kiwitron
Kiwitron KiwiCross Gate K006950 Installation, use and maintenance manual

IDEC
IDEC KW2D Series user manual

Rosslare
Rosslare AY-U9**BT series Installation and user manual

Feig Electronic
Feig Electronic OBID classic-pro ID CPR.03.20-CD installation manual