Universal Remote Control MRFA-3LD-URC User manual

'•
'
•,
6
\i
i
:::"4,
UNIVERSAL•
.
···~.~
remote control ·
........
Light1ng
by
OUTTRON.
~
P/N
030
-1
03
4
Incandescent/Halogen Dimmer with Radio Frequency Receiver
MRFA-3LD-URC
120
V-
60H
z 3
00
W MRFB-3LD-URC
120
V-
60H
z
300
W
Important Notes
Please read before installing.
1. DO NOT use
to
control receptacles, fluorescent lighting fixtures, compact fluorescent (Energy Saver) lamps,
motor-operated
or
transformer-supplied appliances, magnetic low-voltage
or
electronic low-voltage
lighting fixtures.
2. Operate between
32
OF
(0
oq
and 104 °F (
40
°C)
3. Di
mm
ers may feel
wa
rm to
the
tou
ch
during normal operation.
4. Do not use where tot
al
wa
tt
age is u
nde
r
25
W.
5. Do not exceed
ma
ximum l
oad
rat
in
g of Dim
me
r (
300
W)
.
6. DO NOT use Di
mmer
to control table lam
ps
w
1th
a bu
il
t-
in
dimmer
or to
uc
h sensitive 1
8mp
s.
For l
amps
with
bu
ilt-in 3-way
sw
itches, sw
it
ch should
be
set
to
fu
ll
on
pos
ition.
7. Do
not
paint Di
mme
rs or Wireless controllers.
8. Clean with a soft damp cloth only. Do not use any
che
mical cleaners.
9. DO NOT mix U
RC
RF A and B frequency
prod
uc
ts
w1thin
the same s
ys
tem.
Pr
oduc
ts with different frequencies are not
com
patible.
Installation
Connect
the
Dimmer
Pl
ace the Table
Lamp
Di
mmer
1n a convenient and accessible l
oca
tion.
Turn Lamp
ON
and Unplug Lamp Cord
from Receptacle.
EJ
Turn on Dimmer.
, I/
Notes:
1.
The D1
mm
er has a polarized plug (one bl
ade
is wi
der
than the other.)
2. The
po
larized pl
ug
is
not
Intended to be
ma
t
ed
with n
onpo
larized o
ut
lets
(h
aving both slots the same size).
_!
..•
Warning: Do not
op
en, cut cord or re-wire this device. Oth
erw
ise, dea
th
or
se
ri
ous injury
co
uld res
ul
t.
RF Dimmer Operation
Tap Switch
• Tap On/Off
LEOs
In
dicate
li
ght
le
vel.
Gl
ow
• Tap
tw
ice qu
ick
ly:
li
ghts ad
ju
st r
ap
idly to f
ull
On.
softly as a
--+-
night
li
ght
• Press and hold when Dimmer is on:A
de
layed fade to O
ff
can be a
ct
ivated. As the
when
l1
ght
is off.
tap butt
on
is held, the LE
Os
will begin to
fl
ash from
bo
ttom to top. Each flas
hin
g LED
represents an additional 10 seconds of del
ay.
The
li
ghts will fade
to
Off
(up
to
70
seconds of
de
l
ay)
.This procedure must be repeated everytime a fa
de
to
Off is desired.
Dimming Rocker
• Press to Brighten
•
Pr
ess
to
D1
m
Note: Unplug Table
Lamp
C
on
trol
when
ch
ang
in
g light
bu
lbs.
Multiple RF Dimmer Applications
• If multiple URC RF Dimmers are set up
to
the same se
ri
al
numb
e
r,
t
he
y will perform as fo
ll
ows:
• Pressing the
On
b
utt
on on the wireless
con
troll
er
wi
ll
cause a
ll
Di
mm
ers
to
br
ighten to full intensi
ty,
regardless
of
whet
he
r
so
me are on and some are off.
• Pressing the Off butt
on
on the wi
re
less
co
ntro
ll
er w
ill
ca
use a
ll
Di
mm
ers to fade
to
off.
•
To
save a sce
ne
li
ght level, adjust a
ll
the Di
mmer
s
co
ntroll
ed
by
a URC Remote
to
the desired leve
l,
then
pr
ess and hold
the Scene Button on the wireless controller for
ap
pr
oximately 8 s
eco
n
ds
unt
il
the Di
mme
r
's
LEOs stop bli
nk
ing. On
ce
a
scene light level is set, pre
ss
ing the Scene Button w
ill
ca
use each D
imm
er to
re
turn to the scene light leve
l.
• Use
up
to 3 URC se
ri
al nurnbers for each RF Di
mm
er.
Note:Th1s device
mu
st not
be
used to
co
ntrol
equ
i
pm
ent that is n
ot
visible from every control l
ocat
ion. It also must not
be used to
co
ntrol equipment
th
at
co
uld c
re
ate hazardous
si
tu
at
i
ons
such as entrapment if operated
acc
identa
ll
y.
Examples
of
e
qu
i
pmen
t that must not
be
con
tro
ll
ed
by
t
hi
s devi
ce
include (but a
re
not
li
mited to) motori
ze
d gates,
ga
r
age
door
s,
indust
ri
al
doo
rs, microwave ovens, heati
ng
pads, etc. It is
the
installer's res
po
nsibi
li
ty
to
ensure that the eq
ui
pm
e
nt
being
co
nt
ro
ll
ed is visible from every
co
ntrol lo
ca
tion and that only suitable equipment is conn
ec
ted to this devic
e.
·..···
..
\ii
..:
:!Q..
UNIVERSAL.
..·
••.'l'Y
remote co
ntr
ol
<
···
Lighting
5
00
MamaroneckAven
ue
,
Harrison, NY 1
0528
Ph
one
: 1.9
14
.835.4484
OLUTRON . Fax: 1.914.
835.4532
Made a
nd
p
ri
nted in the U.S
.A
4/
09
P/N
030
-1
034
Rev. A
www.UniversaiRemote.com

·
..·
....
;,i
....
...
::IQ>.
UNIVERSAL
~
.
···~.~
remote
control
·:/
Li
ghting
by
(;)WTRON
~
Universal Remote Technical Support
Center
1.914.835.4484
www.
UniversaiRemote.com
Programming a URC Remote Control to Operate a URC RF Lighting Device
If you control your lighting with Universal
Re
mote Control brand
ed
rem
ote controls, and have questions on setting up or
operating these remotes, our CustomerService Support
Center
is here to
he
lp.
If you are an autho
ri
ze
d Universal Remote Control Deal
er
you may
dow
nload the latest con
figu
ration software from our
dealer website:
www.URCControiRoom.com
Call1.914.835.4484 to speak with a customer service
re
presentati
ve
or
email us at [email protected]
500 Mamaroneck Aven
ue,
Harr
ison,
NY
1
0528
Phone: 1.914.835.4484
Fa
x:
1.914.835.4532
www.UniversaiRemote.com
Troubleshooting
Symptoms Possible Causes
Light do
es
not turn o
n,
but
LEOs
on • Light bulb(
s)
burned out.
Control are on. • Switch on lamp turned oft.
Light does not turn on, and
LEO
s on • Circuit breaker is oft or tripped.
Control
are
off. • Cord is not plugged
in.
Dimmer does not dim
pr
operly or • Lamp has a built-in dimmer or 3-way swit
ch
is not
se
t to f
ull
.
fiickers. • Ensu
re
light bulb(s) are more than 25 W
in
candescen
t/
halog
en
.
LEO
s 1and 7 bli
nk
alternately when a • Dimmer
fa
il
ed
to
learn a
RF
Contro
ll
er.
Call
URC
Technical Support
Center
RF
Contro
ll
er button is pressed. at 1.914.835.4484.
Li
ght does not r
es
pond to Radio • Dimmer failed to l
earn
RFController. Ca
ll
URC Technical Support
Center
at
Frequency Contro
ll
er.
1.914.835.448
4.
• Dimmer has already received and responded to a command, or is a
lre
ady at
the
li
ght l
eve
l, the
RF
Controller
is
requestin
g.
•
RF
Controller
is
outside operating
range.
• RFContro
ller
batteries are lo
w.
• RFController ba
tt
e
ri
es
are
in
stalled incorrectly.
When
in
se
t-up mode (tap button • Maximum number of
RF
Contro
ll
ers have been set up to Dimmer.
he
ld)
, L
EO
s 1 and 7 blink alternately. Ca
ll
URC
Technical Support Centerat
1.91
4.835
.4
48
4.
FCC Information:
NOTE
:
T
hi
s e
quipm
e
nt
h
as
b
ee
n tested a
nd
fo
und
to
co
mp
ly with the limits f
or
a Cl
ass
B dig
1t
al dev1
ce
, p
ur
s
ua
nt
to part 15 of the FCC rules. Th
ese
limits are desi
gn
ed to
p
rov
ide re
as
onab
le
pr
otec
tion
ag
a
in
st ha
rmful
in
t
erfe
rence
in
a r
es
id
en
ti
al
in
sta
ll
ati
on.
T
hi
s
eq
uipm
e
nt
generates, u
se
s
and
ca
n radiate radio frequ
enc
y ener
gy
and, if
no
t install
ed
and us
ed
in
acco
rdance with
th
e ins
tr
uc
tions, may cause
ha
rm
ful interferen
ce
to radio and television r
ecep
tion,
wh
ich
c
an
be
determined
by
t
urn
ing the
eq
uipment off
and
on
.
The user is encouraged to try to
co
rrect the inte
rf
eren
ce
by
o
ne
or
mo
re
of
th
e
fo
ll
owing meas
ur
es:
• R
eorient
or re
lo
c
at
e t
he
re
ceiv
ing
a
nt
e
nn
a.
• Inc
re
ase
th
e
se
parat
io
n betwe
en
th
e equipment and
r
eceiver
.
•
Con
nect
th
e eq
ui
pm
ent
in
to an o
utl
et on a c
ir
cuit
different from that to
wh
ich
the
receiver is
co
n
ne
cted.
• Consult
th
e dealer or an experienced radiofTV
technician for help.
C
autio
n:
Changes
or
mo
dific
at
ions not ex
pr
essly a
ppr
o
ve
d
by
Lutron
El
ec
tr
onics
Co
.
co
uld void the user's a
ut
hor
i
ty
to
operate
thi
s e
quipm
en
t
This device c
omp
li
es with Part
15
of the FCC Rules.
Ope
ration
is subject to the fo
ll
ow
1ng
tw
o c
ond
itions:
(1)This devi
ce
may not
ca
use harmful interterence a
nd
(2)
Th
is dev1
ce
rn
ust
ac
cept any interterence rece1ved,
including
1nt
erterence that may cause un
de
sired operation.
This Class B digital ap
pa
r
at
us
co
mp
li
es with Canadian
ICES-
00
3
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and
the
Caribbean.)
Universa
l Re
mot
e
Control
wi
l,at
its
option,
repai
r
or
re
pl
ac
eany
unit
th
at is
defecti
ve
in
materia
ls
or
m
anu
facture
within
one
year
after
pu
rch
ase.
For
warranty
se
rvi
ce,
return
unit
to
plac
e
of
purc
h
ase
or m
ail
to
Uni
v
ersa
l
Remote
Control
at 5
00
Mam
aroneck
Aven
u
e,
Harri
son,
NY
10528,
postage
pre
-
pa
id.
THIS
WARRANTY
IS
IN
LIEU
OF
ALL
OTHER
EXPRESS
WARRANTIES,
AND
THE
IMPLIED
WARRANTY
OF
MERCHANTABILITY
IS
liMITED
TO
ONE
YEAR
FROM
PURCHASE.
THIS
WARRANTY
DOES
NOT
COVER
THE
COST
OF
INSTALLATION
,
REMOVAL
OR
REINSTALLATION
,
OR
DAMAGE
RESULTING
FROM
MISUSE,
ABUSE,
OR
DAMAGE
FROM
IMPROPER
WIRING
OR
INSTALLATION.
THIS
WARRANTY
DOES
NOT
COVER
INCIDENTAL
OR
CONSEQUENTIAL
DAMAGES.
LUTRON'S
LIABILITY
ON
ANY
CLAIM
FOR
DAMAGES
ARISING
OUT
OF
OR
IN
CONNECTION
WITH
THE
MANUFACTURE
,
SALE,
INSTALLATION,
DELIVERY,
OR
USf
OF
THE
UNIT
SHAU
NEVER
EX
CE
ED
THE
PURCHASE
PRICE
OF
THE
UNIT.
Thi
swa
rr
an
ty
g
iv
es
you
spe
cificl
ega
l
rights,
a
nd
you
ma
yh
ave
othe
r
rig
hts
whi
ch
va
ry
from
s
tate
to
state.
Some
stat
es
do
not
allow
the
exc
lu
sion
or
lim
itation
of
in
c
id
enta
l
or
consequent
ial
damages,
or
limita
ti
on
on
how
l
ong
an
implied
wa
rr
anty
mayl
as
t,
so
the
above
limita
tions
may
not
app
lyto
you.
Thi
s
product
is
co
vered
und
erone
or
mor
e
of
the
followi
ng
U.S.
pa
te
nt
s:5,
017
,
837;
5,
248
,91
9;
5,399,940;
5,
63
7,
93
0;
5,798,581;
6,169,377;
6,
38
0
,696
;
7,362
,
285
;
D
353
,
798;
0
439
,
220;
and
co
r
respo
ndin
g
fo
rei
gn
patents
.U.S.
and
forei
gn
patents
pending
.
Lut
ro
na
nd
th
e
sun
burst
logo
are
registered
trademarks
of
Lutron
El
ec
troni
cs
Co
.,
In
c.
©
2009
Lutron
El
ec
tr
onics
Co.
,
In
c.
This manual suits for next models
1
Table of contents