Sinope DM2550ZB-C4 User manual

SINGLE POLE WIRING DIAGRAM
3-WAY WIRING DIAGRAM
Warnings
CAUTION!
This dimmer requires a neutral wire. If your electrical box
does not have a neutral wire, you can either add one or
install the dimmer at a different location.
The installation of this dimmer must be performed by a
certified electrician and comply with the national and local
electrical codes and regulations.
To reduce the risk of overheating and possible damage to
another device, do not install to control an outlet, a motor
or a transformer.
DM2550ZB-C4
Installation Guide
Smart Adaptive
Phase Dimmer
zigbee 3.0
YOUR SMART DIMMER DM2550ZB-C4
INSTALL YOUR DIMMER
Press once to turn ON
the light. Hold down
the button to increase
the intensity.
Press twice to turn on
the light at maximum
intensity.
Press once to turn
OFF the light. Hold down
the button to decrease
the intensity.
Indicator light
Light turned ON = Blue
Light turned OFF = Amber
The indicator intensity can be changed from your
Control4 controller.
Make sure that the breaker for your switch
is OFF at the main electrical panel then
remove the old switch.
Use the provided screws to secure the
dimmer to the electrical box.
Then, place the wall plate.
12Use the provided connectors to
connect the wires as follows:
*Note: For a single pole installation, do
not remove the label on the blue wire.
For a 3-way installation, see the 3-way
wiring diagram section above.
3Power up
the dimmer.
4
Red
Black
White
Blue
Load
Line
Neutral
None*
Make sure to firmly tighten the
wire connectors for a secure
connection. A loose
connection can be a fire
hazard. Special CO/ALR
solderless connectors must be
used when connecting with
aluminum conductors.
Black (line)
Blue (3-way)
White (neutral)
Red (load)
Electrical
Panel
Load
DM2550ZB-C4
Load
Line
Single Pole
switch
Electrical
Panel
DM2550ZB-C4
Red (load)
Black (line)
Blue (3-way)
White (neutral)
Load
red
black
white
blue
load
line
Neutral
white( )
Neutral
(white)
line
load
CONNECT YOUR DIMMER TO A CONTROL4 HOME AUTOMATION SYSTEM
660-2132-0004-A
TECHNICAL SPECIFICATIONS:
MAXIMUM LOAD PER DIMMER FOR A SINGLE
OR A MULTI-GANG INSTALLATION:
Single installation
Multi-gang (2 units)
Multi-gang (3 units)
Protocol: Zigbee 3.0
Frequency: 2.4 GHz
Transmission power: +20 dBm
Receiver sensitivity: -108 dBm
Controller
2nd
1st
3rd
Incandescent
Lamp
600 W
500 W
400 W
600 W
500 W
400 W
150 W
150 W
150 W
Halogen
Lamp
Dimmable
LED / CFL
3-year limited warranty
SINOPE TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3-year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product that has been improperly
installed, misused or accidentally damaged.
The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty,
will be to supply a new unit and this releases the manufacturer from paying the
installation costs or other secondary charges linked to replacing the unit or the
components.
For more information, visit our Website:
Transmitter Module IC: 22394-ZBM1501 / FCC ID:2AK2T-ZBM1501
This device complies with Industry Canada license exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device does not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Operating voltage: 120 Vac, 60 Hz
Operation temp.: 0 °C to 40 °C (32 °F to 104 °F)
Storage: -20 °C to 50 °C (-4 °F to 122 °F)
UL standard: Conforms to ANSI/UL Std. 1472
CSA standard: Certified to CAN/CSA Std. C22.2#184.1
PROVIDED CONNECTORS SPECIFICATIONS:
Stripping length: 16 mm
Wires: 22-10 AWG, Cu
Combinations: Max. 2 #12 & 2 #14, Min. 3 #20 Sol.
16 mm
CALIBRATION ACCORDING TO LOAD
lnitiate the Control4 controller connectivity
session by referring to it's user guide.
1
Connect all your dimmers the same way,
by going to the next closest dimmer.
3When all the dimmers are connected, close the
connectivity session of your Control4 controller
4
Connect your dimmer to the network by
pressing the top button 4 times.
The indicator flashes blue = Connecting
The indicator turns green = Connected
If the connectivity fails, the indicator will
turn red. Refer to our Website to
troubleshoot the unit.
After a few seconds, the indicator
changes color depending on the dimmer status.
(Turned ON = blue, Turned OFF = amber)
2
DISCONNECT YOUR DIMMER FROM A
CONTROL4 HOME AUTOMATION SYSTEM
To disconnect your dimmer from a Control4 controller,
press the 2 buttons of the dimmer simultaneously
for 10 seconds.
This action will also restore the factory settings of
your dimmer. All your settings will be deleted.
10 sec.
First, ensure the load is OFF, and then press and hold the
bottom button for 9-10 seconds until the load turns ON.
Release the bottom button and let the dimmer perform its
calibration routine. This will determine the optimum
parameters for the connected load type.
Perform this operation each time the load is changed.
If you perform a calibration, there is no need to modify
the “One percent ON Adjustment” property.
1
2
3
9-10 sec.
The DM2550ZB-C4 dimmer has a special calibration
function accessible on the device.

Other Sinope Dimmer manuals

Sinope DM2500ZB User manual

Sinope

Sinope DM2500ZB User manual

Sinope DM2550ZB User manual

Sinope

Sinope DM2550ZB User manual

Sinope DM2500ZB User manual

Sinope

Sinope DM2500ZB User manual

Sinope DM2550ZB User manual

Sinope

Sinope DM2550ZB User manual

Popular Dimmer manuals by other brands

Rogers Jasco Setup guide

Rogers

Rogers Jasco Setup guide

LEGRAND MIRO MRP6 installation instructions

LEGRAND

LEGRAND MIRO MRP6 installation instructions

Leviton VZX12-7L installation instructions

Leviton

Leviton VZX12-7L installation instructions

Lutron Electronics Energi TriPak Series Quick start quide

Lutron Electronics

Lutron Electronics Energi TriPak Series Quick start quide

Lutron Electronics Caseta quick start guide

Lutron Electronics

Lutron Electronics Caseta quick start guide

ETC Unison Echo Forward-Phase Dimmer-Gen 2 installation guide

ETC

ETC Unison Echo Forward-Phase Dimmer-Gen 2 installation guide

Niko 65-411 manual

Niko

Niko 65-411 manual

Quick HDIM300 Manual of use and maintenance

Quick

Quick HDIM300 Manual of use and maintenance

Targetti LMS 1T5351 manual

Targetti

Targetti LMS 1T5351 manual

Shelly PLUS quick start guide

Shelly

Shelly PLUS quick start guide

MOLTO LUCE DALI DT8 Mounting instruction

MOLTO LUCE

MOLTO LUCE DALI DT8 Mounting instruction

INSTEON LampLinc 2457D2 quick start guide

INSTEON

INSTEON LampLinc 2457D2 quick start guide

Stairville D1210 owner's manual

Stairville

Stairville D1210 owner's manual

Jung 225 NV DE quick start guide

Jung

Jung 225 NV DE quick start guide

Unex 25716-008-89 operating manual

Unex

Unex 25716-008-89 operating manual

Crestron CNLDAB-4A Brochure & specs

Crestron

Crestron CNLDAB-4A Brochure & specs

Jung 243 EX operating instructions

Jung

Jung 243 EX operating instructions

LEGRAND Celiane 672 32 manual

LEGRAND

LEGRAND Celiane 672 32 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.