USA Measurements Army iCount US-iC Series User manual

1
Electronic Counting
Scale Manual

2
Contents
【
1
】
ATTENTION..........................................................3
1.1 CONVENTIONAL ATTENTION
1.2 ATTENTION BEFORE USING
【
2
】
INSTALLATION……………………………………4
2.1 BODY INSTALLATION
2.2 BATTERY REPLACEMENT
【
3
】
INSTRUCTION………………………………………5
3.1 PARAMETERS
3.2 POWER SUPPLY
【
4
】
DISPLAY…………………………………………….6
4.1 PANEL DESCRIPTION
4.2 KEY DESCRIPTION
4.3 DISPLAY DESCRIPTION
【
5
】
OPERATION……………………………………..…9
【
6
】
FUNCTION SETTING…………………………….20
【
7
】
RS232 OUTPUT FORMAT……………………….25
【
8
】
ERROR MESSAGES ………………………..….27
【
9
】
SPECIFICATIONS…………………………………28
【
10
】
WARRANTY…………………………………..……28

3
First of all, thank you for purchasing the USA Measurements
Army “iCount” US-iC series electronic counting scale from our
company. The high quality and reliability of our products are
the best in the measurements industry. There are specific
methods of installation, operation, and maintenance in this
manual that are very important to adhere to. In order for your
scale to work well, you must read the manual carefully before
using.
【
1
】
ATTENTION
l Do not let anything drop onto the pan.
l Do put the scale in a dangerous enviornment.
l Keep the scale in a level area unobstructed by objects.
l Do not count pieces on the scale or move around the pan.
l Keep the scale clean. If the product is not going to be
used for a long period of time recharge the battery once a
month. When the scale has been inactive for a period of
time it is necessary to charge the battery before using the
scale again.
l We suggest all maintenance to be done by a technician.

4
1.1 ATTENTION BEFORE USING
1. Place the scale on a clean, firm, flat surface without the
pan on top and keep away from any kind of vibration, heat, or
harsh changing temperatures. Adjust the 4 leveling feet so
that the bubble is centered in the circle and be sure the scale
is level each time you move the product.
2. Connect the AC adapter to an independent power supply to
avoid interference from other equipment.
3. Scale pan must be empty when turning on the scale.
4. The first time setting up the scale wait 3-5 minutes for the
scale to autocalibrate.
5. For best weighing accuracy, the center of gravity for an
object should be placed in the center of the pan and not in the
corner or edge of pan.
【
2
】
INSTALLATION
2.1 BODY INSTALLATION
1
.
Contents in Carton
No.
Name
Unit
Qty.
1
Body
pc
1
2
Pan
pc
1
3
Manual
pc
1

5
4
Calibration
pc
1
5
Inner Packing
pc
1
6
AC Adapter
pc
1
2. Put the scale on a firm and horizontal surface, adjust the
feet to keep the scale stable and level the feet till the bubble is
centered in the circle.
3. Put the pan on the body and press
【
ON/OFF
】
key to turn on
the scale in weighing mode.
2.2 BATTERY REPLACEMENT
1. Take off the stainless steel pan, open the housing, and
disconnect the battery connectors.
2. Install the new battery in same position and connect
negative and positive poles correctly.
Warning
:
The positive and negative poles of lead-acid battery
installed incorrectly can cause a short circuit or electrode
reverse, which will damage the battery and may cause a fire.
Connection: Red wire to red pole and black wire to black pole.
3. Screw back in the housing and place the weighing pan on
the scale. After that the battery replacement is complete.

6
【
3
】
INSTRUCTION
3.1 PARAMETERS
Accuracy
:
III
Number of Division
:
(3000-300000
)
d
,(
3000d,dual range
)
approved
Working Voltage
:
5V
Sample Rate: 20 times/Sec.
Resolution
:
1 million
3.2 POWER SUPPLY
AC Adapter
:
Input 100V~240V
,
Output 12V/1A
Battery Specification: 6V4AH
【
4
】
DISPLAY
4.1 PANEL DESCRIPTION
US-iC Panel

7
Description
:
HI (red light),OK (green light) and LO (yellow
light) indicates when check weight function works.
4.2 KEY DESCRIPTION
【
0~9
】:
The input number displayed on the screen
【
.
】:
Decimal Point
【
C
】:
Clear the displayed numbers on screen
【
SMPL
】:
Calculate a new average unit weight
【
RSMPL
】:
Recalculate a new average unit weight
【
ON/OFF
】:
Powers unit on or off
【
TARE
】:
Perform Tare Function
【
ZERO
】:
Perform Zero Setting Function
【
PRINT
】:
Perform Print Function
【
UWS
】:
Confirm the input unit weight value
【
CK
】:
Cooperate with other keys to set the upper-lower limit
【
RETURN
】:
Return to weighing interface when setting
【
M+/HI
】:
1. Perform accumulation function in weighing mode,
then the symbol M+ is bright 2. Cooperate with check weight
key to input the upper limit.
【
MR/LO
】:
1. Perform to redisplay function in weighing mode,
then the symbol MR is bright

8
2.Cooperate with check weight key to input the lower limit.
【
MC
】:
Press to clear accumulated value , then the symbol
MC is eluminated.
Notice:
:
The time for pressing any key is less than 1 second.
4.3 DISPLAY DESCRIPTION
No.
Description
No.
Description
1
Stable Symbol
7
MR Symbol
2
Zero Symbol
8
MC Symbol
3
- Symbol
9
R1 cap. Symbol
4
NET Symbol
10
R2 cap. Symbol
5
Battery Symbol
11
Samples Lack
6
M+ Symbol
Input Unit Weight Lack
Weight Unit Weight
COUNT
1
2
3
4
5
6
7
8
9
10
11

9
【
5
】
OPERATION
5.1 TURN ON/OFF
ON
:
Press
【
ON/OFF
】
key to display the maximum capacity
and software version on the display, scale will perform a
self-inspection, and then enter into the weighing mode.
OFF
:
Press
【
ON/OFF
】
key to turn off the scale.
5.2 COUNTING MODE
There are three display windows in the US-iC series scale, in
which weight, unit weight and count are displayed.
5.3 AVERAGE UNIT WEIGHT SETTING
If average unit weight was not set beforehand, “0” will be
displayed in the unit weight and count screen.
Sampling
:
1. Place a samples onto the weighing pan.
2. Input the number of samples by numeric keyboard, and
then input numbers are displayed on unit weight screen .

10
3. Press
【
SMPL
】
key to display the unit weight value on unit
weight screen and the sampling value on count screen.
4. The set average unit weight and number are displayed on
the screens.
Sampling After Tare:
1. Put a container on the pan
2. Press
【
TARE
】
key to display “0” on weight screen.
and NET symbol is displayed.
3. Put samples inside the container
4. Input the number of samples by numeric keyboard and the
number is displayed on unit weight screen.
5. Press
【
SMPL
】
key to display the unit weight value on unit
weight screen and sampling value on count screen.
Input a known average unit weight:
1. A known unit weight is input, then press
【
UWS
】
key to
display “ unit weight value” on unit weight screen.
2. Put entire sampled units onto the pan
3. Count and get the result

11
5.4 ACCUMULATED MODE
Perform accumulation function by pressing
【
M+/HI
】
key,
and accumulative operation can be performed at most 10
times as well as rechecking or by printing each time.
Notice: The accumulative operation can only be performed
when the stable symbol appears, then M+ symbol will be
displayed after performing accumulative operation.
1. Sampling and count according to the item 5.3
2. Press
【
M+/HI
】
key to display “ present accumulated
times” for short time on unit weight screen, and one
second later, automatically return in counting interface.
3. The multiple accumulative operation can be performed by
the step 2
5.5 REDISPLAY FUNCTION
The redisplay function can be used to check accumulated
results and to examine accumulated information line by line.
After performing redisplay operation, MR symbol will then be
displayed.

12
1. One or more times accumulative operation can be
performed according to item 5.4
2. Press
【
MR/LO
】
key to display “weighing value of
accumulative total” on the weight screen, “MR-ALL (times
of accumulative total)” on the unit weight screen, “the
number of accumulative total” on count screen. Press
the print key to print the accumulative total.
3. Press continuously
【
ZERO
】
key to examine the
information of 10 times accumulated results in
descending order.
4. Press continuously
【
TARE
】
key to examine each
information of 10 times accumulated results in ascending
order.
5. Press
【
RETURN
】
key to return in counting interface.
5.6 CLEAR ACCUMULATION FUNCTION
Clear Accumulation Function can be used to clear the
accumulated results and the accumulated value each time.
MC symbol will be displayed after clearing accumulation.
1. One or more times accumulated operation can be
performed according to item 5.4

13
2.
Press
【
MC
】
key to display “weighing value of
accumulative total” on weight screen, “MR-ALL(times of
accumulative total)” on unit weight screen, “the number of
accumulative total” on count screen. Press
【
MC
】
key
again to clear all the accumulated information and cancel
accumulation operation.
3. Press continuously
【
ZERO
】
key to examine each
information of 10 times accumulated results in descending
order and press
【
MC
】
key to clear the present accumulated
information.
4. Press continuously
【
TARE
】
key to examine the information
of 10 times accumulated results in ascending order and
press
【
MC
】
key to clear the present accumulated results.
5. Press
【
RETURN
】
key to return to counting interface.
5.7 CHECK WEIGHT
Check Weight mode and check weight alarm range function
can be set under function setting mode. The setting
instructions are shown in the chapter of function settings.
Notice: the operation can only be performed when LO is less
than HI and more than 9d.

14
1. In counting interface, press
【
CK
】
key to display “check
weight alarm range” on weight screen, “unit weight value”
on unit weight screen, “LIMIT” on count screen.
2. Press
【
MR/LO
】
key to display “check weight alarm
range” on weight screen, “lower limit weight” on unit
weight screen, “LO” on count screen. Change the lower
limit weight by numeric keyboard, press
【
SMPL
】
key to
confirm the lower limit weight.
3. Press
【
M+/HI
】
key to display “check weight alarm
range” on weight screen, “upper limit weight” on unit
weight screen, “HI” on count screen. Change the
upper-limit weight by numeric keyboard, press
【
SMPL
】
key to confirm the upper limit weight.
4. Press
【
RETURN
】
key to return in counting interface.
5. Press
【
CK
】
key and press
【
RSMPL
】
key again to open
check weight function.
6. Press
【
CK
】
key and press
【
RETURN
】
key again to close
check weight function.
5.8 CHECK COUNT

15
Check Count mode and check count alarm mode can be set
to function setting. The setting instructions are shown in the
chapter of function settings.
Note: the operation can only be performed when LO is less
than HI, integer number and more than 9d
1. In counting interface, press
【
CK
】
key to display “check
count alarm range” on weight screen, “ unit weight” on unit
weight screen, “LIMIT” on count screen.
2. Press
【
MR/LO
】
key to display “check count alarm range”
on weight screen, “lower-limit count” on unit weight screen,
“LO” on count screen. Change the lower-limit count by
numeric keyboard, press
【
SMPL
】
key to confirm the
lower-limit count.
3. Press
【
M+/HI
】
key to display “check count alarm range” on
weight screen, “upper-limit count” on unit weight screen,
“HI” on count screen. Change the upper-limit count by
numeric keyboard, press
【
SMPL
】
key to confirm upper-limit
count.
4. Press
【
RETURN
】
key to return in counting interface.
5. Press
【
CK
】
key and press
【
RSMPL
】
key again to open the
check count function.

16
6. Press
【
CK
】
key and press
【
RETURN
】
key again to close the
check count function.
5.9 SINGLE POINT CALIBRATION (unapproved)
Single Point Calibration can be used to calibrate the deviation
of gravity when the scale is first used to calibrate the scales
inaccuracy.
Notice: please calibrate the scale in working conditions.
1. In the power off mode, hold on
【
SMPL
】
key and press
【
ON/OFF
】
key to enter in function setting and display
“set” on weight screen , “0” on unit weight screen.
2. Input “1139” by pressing numeric keys and press
【
SMPL
】
key to display “CAL” on weight screen, “1Point” on unit
weight screen, “C-ZEro” on count screen.
3. Confirm there is no load on the pan and press
【
TARE
】
key
to perform single point calibration ,display “value of
weight to load” on count screen.

17
4. If“ value of weight to load” needs to be changed,
respectively press
【
TARE
】【
ZERO
】
keys to change the
value of weight to load.
5. Put required weight on the pan for 3-5 seconds and press
【
SMPL
】
key to display “pass”, then take off the weight,
press
【
SMPL
】
key again to return to function setting
interface.
6. Press
【
RETURN
】
key to count backwards to return in
weighing interface.
5.10 UNIT SETTING
(
unapproved
)
In general, the unit will not need to be reset because they
were already set before delivery. If setting up is needed,
the steps are shown in –g.kg,1b,oz
Notice: The units kg and g are only allowed by rules to be
legal measure unit.
1. In the of power off mode, hold down
【
SMPL
】
key and press
【
ON/OFF
】
key to enter in function setting, display “set”
on weight screen and “0” on unit weight screen.
2. Input“1132” by numeric key, and press
【
SMPL
】
key to
display “UNIT” on weight screen, “1132” on unit weight
screen, “Unit” on count screen.

18
3. Press
【
1
】
key to change the units and select required
unit ,press
【
SMPL
】
key to return in function setting
interface.
4. Press
【
RETURN
】
key to count backwards again to return in
weighing interface.
5.11 MINIMUM ZERO DISPALY SETTING
Minimum Zero Display need not reset in general and was set
before delivery, if need, the steps are shown as the followings:
Notice: Minimum Zero Display “0” is only allowed to be set on
rules.
1. In the condition of power off, hold on
【
SMPL
】
key and press
【
ON/OFF
】
key to open function setting ,display “SET” on
weight screen and “0” on unit weight screen.
2. Input“1136” by numeric keys and press
【
SMPL
】
key to
display “Auto-Z” on weight screen, “1136” on unit weight
screen, “Minimum Zero Display” on count screen.
3. Press
【
1
】
key to change the different minimum zero display
(0-1-2-3), and select the required one, then press
【
SMPL
】
key to return in function setting interface.

19
4. Press
【
RETURN
】
key to count backwards, and return in
weighing interface.
5.12 LINEAR CALIBRATION
(
unapproved
)
There are three portions for linear calibration in the range of
scale capacity. The incorrect linear calibration method will
make errors so that the measured value will be influenced
each time. Therefore, the linear calibration done by user are
not suggested. The linear calibration was done before
delivery.
Notice: please calibrate the scale in working conditions.
1. In the condition of power off, hold on
【
TARE
】
key and press
【
ON/OFF
】
key to enter in linear calibration interface, and
display “CAL” on weight screen, “LinE” on unit weight
screen, “C-ZEro” on count screen.
2. Confirm no load on the pan, press
【
TARE
】
key to set zero
point calibration, display “1/3 maximum capacity” on count
screen.
3. Put the required weights on the pan for 3-5 seconds, press
【
TARE
】
key to enter in next portion linear calibration
interface, display “2/3 maximum capacity” on count screen.

20
4. Put the required weights on the pan for 3-5 seconds, press
【
TARE
】
key to enter in third linear calibration interface,
display “3/3 maximum capacity” on count screen.
5. Put the required weight on the pan for 3-5 seconds, press
【
TARE
】
key to display “PASS” on count screen.
6. Press
【
TARE
】
key to count backwards to return in weighing
interface.
【
6
】
FUNCTION SETTING
In the condition of power off, hold on
【
ZERO
】
key and press
【
ON/OFF
】
key to enter in function setting interface and
display “SCALE” on weight screen, “FunC” on unit weight
screen, “SET” on count screen.
**********************************************************
6.0 BACKLIGHT SETTING
Press
【
0
】
key to display “FunC0” on weight screen, “LiGh” on
unit weight screen, “backlight type” on count screen. Press
【
0
】
key to change backlight type.
“OFF”
:
No Backlight
“ON”
:
Backlight is bright
Table of contents
Other USA Measurements Scale manuals