uSave LED USHIBAYR WPL Series User manual

CAUTION: PLEASE FOLLOW THIS
INSTRUCTION MANUAL CAREFULLY
TO PREVENT ANY INJURIES OR
COMPLICATIONS THAT MAY ARISE.
WARNING: Before installing or maintaining
the luminary, make sure all powers are
TURNED OFF.
Verify that supply voltage is correct by
comparing it with the label information on all
fixtures. Make all connections in accordance
with the NEC requirements, and make sure
all luminaries are properly secured to prevent
any wire complications.
USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
TRUNNION
MOUNT
Hook Mount
CHAIN WITH EYE-
HOOK (NOT
INCLUDED)
SAFETY CORD
J-BOX
(NOT
INCLUDED)
OPTION 2: The luminaires also come
with a Trunnion Mount which can be
used to surface mount the fixture in
various positions covering an 180°
spread. It has 3 openings which can
be used to fasten the fixture onto a
surface with bolts.
(bolts not included)
OPTION 1: The luminaires come with a
Hook Mount which can be used to install
into a Eye Hook (Not Included). Screw in
the Hook Mount into the back Threaded
hole in the luminaire. Tighten the hook
properly and mount it to the Eye Hook.
DIMMABLE
LED
DRIVER
V(-)
[BLUE]
V(+)
[BROWN]
TO LOAD
[LED BOARD]
[WHITE]
[BLACK]
ACN [WHITE]
ACL [BLACK]
GROUND [GREEN]
NEUTRAL [WHITE]
GROUND [GREEN]
HOT [BLACK]
INPUT
OUTPUT
DIM
BLACK(-)
INSIDE J-BOX PRE-CONNECTED
(DO NOT DISCONNECT)
3. All wiring connections must be
made inside a Junction Box.
Make sure to choose the correct
junction box for the desired
application. Some junction boxes
are made for outdoor applications
and others are made for indoor
applications.
4. All fixtures also come with a
Safety Cord used as an extra
precaution to prevent any
accidents.
The Safety Cord is pre-installed
in the fixture and should be able
to be connected to the chain
which is firmly installed to the
ceiling or surface.
SAFETY
CORD
GRAY(+)

USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
“ON-TRUNNION MOUNT”, SLIP-FITS OVER A
2” POLE OR TENON (2.375” O.D.)
PART NO. DESCRIPTION QTY PART NO. DESCRIPTION QTY
1ACFLSF- Slipfitter Mount, Slip-fits over a
2” pole or tenon (2.375” O.D.)
1 4 10-00046- M8-1.25 x 15 mm Hex Head
Machine Bolt
2
2 10-00047- Waterproof Cable Gland 1 5 10-00040- Washer for M8-1.25 Bolt 2
3 10-00028- M8-1.25 x 16 mm Socket
Head Machine Bolt
2
2
1
3
5
4
EXPLODED VIEW
2. Run AC cable through
Slipfitter and seal with
waterproof cord connector.
1. Loosen the (2) M8-1.25
Hex Head Bolts from the
ACFLSF Slipfitter mount.
Align the ACFLSF Slipfitter to
the fixture handle and fasten
the two pieces together using
the [2] Hex Head Bolts and
washers.
3. The hole on top of the Slipfitter is used to mount a waterproof cable gland. This is used
to get the AC Input cable from the luminaire into the slipfitter.
4. The Slipfitter should be mounted onto a hollow round 2” part with AC Power cords
running inside of it. Make sure all powers are off. Follow the wiring diagram provided in
order to install the luminaire to the AC Power Supply.

CAUTION: PLEASE FOLLOW THIS
INSTRUCTION MANUAL CAREFULLY
TO PREVENT ANY INJURIES OR
COMPLICATIONS THAT MAY ARISE.
WARNING: Before installing or maintaining
the luminary, make sure all powers are
TURNED OFF.
Verify that supply voltage is correct by
comparing it with the label information on all
fixtures. Make all connections in accordance
with the NEC requirements, and make sure
all luminaries are properly secured to prevent
any wire complications.
USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
STEP 1: Using an Allen
Screw, Remove the [4] Socket
head Machine bolts from the
back side of the High Bay
luminaire.
PART NO. IMAGE DESCRIPTION QTY
ACHWSF “On Fixture” Slipfitter Mount, Slip-fits over a
2” pole tenon (2.375”).
1
“ON FIXTURE” SLIPFITTER MOUNT
STEP 2: Fasten the
ACHWSF part with the [4]
mounting holes using the
same socket head
machine bolts that were
removed in Step 1.
STEP 3: Using the M12
Machine Screw, Run the
cables from the fixture,
through the ACHWSF
Slipfitter.
STEP 4: Before completely tightening
the two parts of the slip-fitter together,
make sure to orient the angle designed.
Once you have adjusted the Slip-fitter
to the desired orientation, fasten the
M12 bolt.

USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
PART NO. IMAGE DESCRIPTION QTY
ACHWRF90 90° REFLECTOR 1
10-00070
M5-0.8 Thread x 18 mm Long
3
90° REFLECTOR
STEP 2: Using a Phillips Screw
Driver, Fasten the [3] provided
machine screws from the inside
portion of the 90° reflector to
secure it into place.
STEP 1: Align the following
holes from the reflector with
the holes on the luminaire
without fasteners.

USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
MICROWAVE OCCUPANCY DETECTION
& DAYLIGHT HARVESTING SENSOR
NEUTRAL [WHITE]
GROUND [GREEN]
DIM
INPUT
TO LOAD
[LED BOARD]
LINE [BLACK]
WHITE (-)
/BLACK(-)
BLUE(+)
/GRAY(+)
ACL (BROWN)
ACN (BLUE)
DIM (+) [RED]
DIM (-) [BLACK]
L out [YELLOW]
N [BLUE]
L in [BROWN]
DIM (+) [RED]
DIM (-) [BLACK]
1) Remove the two [2] #4-40 PHMS from the ACHUMO-MB bracket of the ACHUMO
and remove the small phillips screw from underneath the sensor in order to replace the
ACHUMO bracket with the ACHUMO3-MB . Using a Phillips screw driver (preferable
with a magnetic tip), Fasten the bracket onto the FHW luminaire and use the hexnuts
provided to lock it in place.
2) Remove the ACHUPS sensor from the ACHUPS-MB, and install the sensor to
the ACHUMO3-MB. Make sure the orientation of the sensor is the same as the
day harvesting detector.
3) Use the Wire Diagram provided for the required connections. Make sure all wiring
connections are made inside the J-Box provided and are properly sealed by an
authorized electrician.
4) Refer to the Individual installation sheets for the ACHUMO and the ACHUPS for
adjusting the settings on the Microwave sensor and the Daylight Harvesting
Detector.
PART NO. IMAGE DESCRIPTION QTY
ACHUPS Photocell/Daylight harvesting Sensor,1-10Vdc Dim
down/up according to ambient brightness level,
target light level adjustable. Ip20 rated.
1
ACHUMO Microwave occupancy sensor with
J-Box
1
ACHUMO3-MB Mounting Bracket for the ACHUMO Microwave
Sensor and ACHUPS Daylight Harvesting Sensor
to the FHW luminaire.
1
10-00033 #4-40 Pan Head Machine Screw 2
10-00033 #4-40 Hex Nut 2
ACHUMO
ACHUPS
ACHUMO
ACHUPS
AC POWER
SUPPLY
DIMMABLE LED DRIVER
FOR INDOOR USE ONLY
CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL
CAREFULLY TO PREVENT ANY INJURIES OR COMPLICATIONS
THAT MAY ARISE.
WARNING: Before installing or maintaining the luminaire, make sure all powers
are TURNED OFF. Verify that the supply voltage is correct by comparing it with
the label information on all fixtures. Make all connections in accordance with the
NEC requirements, and make sure all luminaries are properly secured to prevent
any wire complications. This luminaire is not to exceed the maximum ambient
temperature rating noted on the specification sheet.
When ACHUMO microwave sensor works together with the ACHUPS
daylight harvesting sensor, the lighting fixture will dim the light in response to
the available daylight in the area when the area is being occupied.
When the customer orders the ACHUMO and the ACHUPS, a special
mounting bracket will also be included (ACHUMO3-MB). This mounting bracket
is specifically made to be able to mount both the sensor and occupancy
detector simultaneously. Each luminaire already comes with two holes made
specifically for this bracket.
LED INPUT LED DIM
AC POWER
SUPPLY CORD ACHUMO
LED DRIVER
INPUT CORD
DRIVER DIM
& ACHUPS
THIS DIAGRAM IS A
RECOMMENDATION ON HOW TO
INSTALL THE WIRING INSIDE THE
JUNCTION BOX. APPLY WATERPROOF
SEALANT AFTER ALL WIRING IS
COMPLETE.

PART NO. IMAGE DESCRIPTION QTY
ACHUPS Photocell/Daylight harvesting Sensor,1-10Vdc Dim
down/up according to ambient brightness level,
target light level adjustable. Ip20 rated.
1
ACHUPS-MB Mounting Bracket for the ACHUPS
Photocell Sensor
1
10-00032 #4-40 Pan Head Machine Screw 2
10-00033 #4-40 Hex Nut 2
USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
DAYLIGHT HARVESTING SENSOR
INSTALLATION STEPS
V(-)
[BLACK]
V(+)
[RED]
TO LOAD
[LED BOARD]
[WHITE]
RED (+)
BLACK (-)
DIMMING
INPUT
NEUTRAL [WHITE]
LINE [BLACK]
ACL
(BLACK)
ACN (WHITE)
CONNECTION TO (DAYLIGHT
HARVESTING SENSOR
ACHUPS)
[BLACK]
DIMMABLE LED DRIVER
AC POWER
SUPPLY
GRAY (-)
PURPLE (+)
ACHUPS-MB
1) Remove the two [2] #4-40 PHMS from the mounting bracket.
Using a Phillips screw driver (preferable with a magnetic tip), Fasten
the bracket onto the FHW luminaire (all fixtures have two small
holes specifically made for the ACHUPS-MB bracket and use the
hexnuts provided to lock it in place.
2) Refer to the wiring diagram to connect the ACHUPS to the
Dimmable LED Driver.
3) Make sure all wiring connections are made inside a J-Box. Since
the Daylight Harvesting Sensor is to only be used indoors. It must
be an Indoor J-Box.
ACHUPS
10-00032
10-00033
Inside J-Box ( Not Included)
4) On the photocell, there is a small
adjustable knob with a (+) and (-) sign,
this knob is the Potentiometer for
adjusting the light level desired. It is
recommended for the target light level
to be between 40% to 80% of the total
lux of luminaires.
CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL
CAREFULLY TO PREVENT ANY INJURIES OR
COMPLICATIONS THAT MAY ARISE.
WARNING: Before installing or maintaining the luminaire, make sure all powers
are TURNED OFF. Verify that the supply voltage is correct by comparing it with
the label information on all fixtures. Make all connections in accordance with the
NEC requirements, and make sure all luminaries are properly secured to prevent
any wire complications. This luminaire is not to exceed the maximum ambient
temperature rating noted on the specification sheet.

USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
MICROWAVE OCCUPANCY DETECTION
INSTALLATION STEPS
PART NO. IMAGE DESCRIPTION QTY
ACHUMO Microwave occupancy sensor with
J-Box
1
ACHUMO-MB4 Mounting Bracket for the ACHUMO
occupancy sensor
1
10-00032 #4-40 Pan Head Machine Screw 2
10-00033 #4-40 Hex Nut 2
2) Refer to the wiring diagram provided to
connect the ACHUMO to the Dimmable LED
Driver. Try to aim the sensor toward the
desired detectable area.
3) Make sure all wiring connections are
made inside the J-Box provided and are
properly sealed by an authorized electrician.
4) Remove the screw and cap of the sensor
and adjust the DIP switches to get the
desired settings. Sensor data can be
precisely set for each specific application.
Once the program is set, close and fasten
the cap.
(1) DETECTION AREA
Detection area can be reduced by selecting
the combination on the DIP switches to fit
precisely each application
(2-4) HOLD TIME
Refer to the time period the lamp remains at
100% illumination after
no motion detected
(8-9) STAND-BY DIMMING LEVEL
The low light level you would
like to have after the hold
time in the long absence of people
(5-7) STAND-BY PERIOD
Refer to the time period the lamp
remains at 100% illumination after
no motion detected
(10-12) DAYLIGHT SENSOR
The sensor can be set to only allow
the lamp to illuminate below a defined
ambient brightness threshold.
When set to Disable mode, the daylight
sensor will switch on the lamp when motion is
detected regardless of ambient light level.
Note that daylight sensor
is active only when lamp totally switches off.
ONON
ONON
ONON
11
223344
8899
II
IIII
II
IIII
IIIIII
IVIV
VV
VIVI
II
IIII
IIIIII
IVIV
ONON
--
100%100%
50%50%
ONON ONON ONON
ONON ONON
ONON
ONON
ONON ONON
--
--
ONON
--
--
--
--
----
5 s5 s
30 s30 s
90 s90 s
3min3min
20min20min
30min30min
ONON ONON
ONON
--
ONON
--
50%50%
30%30%
-- 20%20%
-- 10%10%
ON
ON
56 7
10 11 12
I
II
III
IV
V
VI
I
II
III
IV
ON ON ON
ON ON
ON
ON
ON ON
-
-
ON
-
-
-
-
--5 s
10min
5 min
30min
60min
60m+
ON ON ON
ON
ON
--
-
-
---
Disable
20 lux
10 lux
5 lux
1) Remove the two [2] #4-40 PHMS from
the mounting bracket. Using a Phillips
screw driver, fasten the bracket onto the
luminaire and use the hexnuts provided to
lock it in place.
CAUTION: PLEASE FOLLOW THIS
INSTRUCTION MANUAL CAREFULLY
TO PREVENT ANY INJURIES OR
COMPLICATIONS THAT MAY ARISE.
WARNING: Before installing or
maintaining
the luminary, make sure all powers are
TURNED OFF.
Verify that supply voltage is correct by
comparing it with the label information
on all fixtures. Make all connections in
accordance with the NEC requirements,
and make sure all luminaries are
properly secured to prevent any wire
complications.
DIMMING
INPUT
WHITE (-)
/BLACK (-)
BLUE(+)
/GRAY(+)
ACL (BROWN)
ACN (BLUE)
AC POWER SUPPLY
DIMMABLE LED DRIVER
G N L
DIM (+) [RED]
DIM (-) [BLACK]
L out[YELLOW]
LUE]
L in [BRON [BWN]
WIRING DIAGRAM

PART NO. IMAGE DESCRIPTION QTY
ACHUOS Passive infrared occupancy sensor, 120-277v.
Adjustable Timer and Sensitivity. Includes the
ACHUOS NUT. Indoor Use Only
1
ACHUOS-MB Mounting Bracket for the ACHUOS
Photocell Sensor
1
10-00032 #4-40 Pan Head Machine Screw 2
10-00033 #4-40 Hex Nut 2
USHIBAYRxxxWPL (300W-480W) Series LED Highbays Installation Guide
PIR OCCUPANCY DETECTION
NEUTRAL [WHITE]
GROUND [GREEN]
DIMMING
INPUT
TO LOAD
[LED BOARD]
LINE [BLALINE [BLACK]CK]
ACL (BLACK)
ACN (WHITE)
[RED]
[WHITE]
[BLACK]
DIMMABLE LED DRIVER
ACHUOS WIRING
DIAGRAM
AC POWER
SUPPLY
ACHUOS-MB
ACHUOS
ACHUOS NUT
The ACHUOS comes with a black mounting bracket made specifically to
be installed with the luminaire. Each luminaire already comes with a
hole made specifically for this bracket.
1)Make sure all Powers are OFF.
2) Remove the custom gear-shaped washer in order to remove the
mounting bracket from the ACHUOS sensor. Be sure to not misplace any
parts since they will all have to be used for later steps.
3) Remove the two [2] #4-40 PHMS from the mounting bracket. Using a
Phillips screw driver (preferable with a magnetic tip), Fasten the bracket
onto the luminaire and use the hexnuts provided to lock it in place.
4) Once the mounting bracket is fastened onto the fixture, one can now
mount the sensor onto the bracket using the same custom gear-shaped
washer.
5) Refer to the wiring diagram provided to connect the ACHUOS to the
LED Driver.
6) Make sure all wiring connections are made inside a J-Box and are
properly sealed by an authorized electrician.
7) Seal the sensor opening to prevent any liquids from entering
8) Adjust the [3] knobs to get the desired setting.
SEAL SENSOR
OPENING WITH
SILICON GEL
(NOT INCLUDED)
TO PREVENT ANY
MOISTURE OR LIQUIDS
FROM ENTERING
INSIDE
1
10
5
20
30
1
3
2
4
5
1
3
2
4
5
TIME SENSE LIGHT
Time Delay Knob
(in minutes)
Sensor Sensitivity
Range Knob
1 =50%
(Default) 3 = 75%
5=100%
Ambient Light
Level Knob
Default= 5 (Daylight)
FOR INDOOR USE ONLY
CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL
CAREFULLY TO PREVENT ANY INJURIES OR COMPLICATIONS
THAT MAY ARISE.
WARNING: Before installing or maintaining the luminaire, make sure all powers
are TURNED OFF. Verify that the supply voltage is correct by comparing it with
the label information on all fixtures. Make all connections in accordance with the
NEC requirements, and make sure all luminaries are properly secured to prevent
any wire complications. This luminaire is not to exceed the maximum ambient
temperature rating noted on the specification sheet.
GRAY (-)
PURPLE (+)
Table of contents
Popular Lantern manuals by other brands

Eaton
Eaton Streetworks SDL LED Arm Mount installation instructions

Cooper
Cooper MEDC Filament FB11 Technical manual

Clevertronics
Clevertronics Argonaut PRO ARGOPRO-1200 Series Installation & maintenance instructions

DOTLUX
DOTLUX 2528-0FW120 user manual

BEGA
BEGA 84 421 Instructions for use

GE
GE Versaflood III instructions

Reimo
Reimo STELLA User instruction

MUNDUS
MUNDUS Silva instruction manual

Ilti Luce
Ilti Luce BLUX08034250AA Mounting instructions

Eaton
Eaton CrystalWay CGLine+ 40071354590 manual

Intermatic
Intermatic Malibu LZ6 instructions

Overland Vehicle Systems
Overland Vehicle Systems UFO Solar Camp Light & Speaker instruction manual