UseTECH FlowTimer+ Detect RF Set User manual

FlowTimer+ Detect RF Set
Direct water detection
with the FlowTimer+ System
Operating manual

Publisher
usetech GmbH
Tanzplatz 10
D- 55130 Mainz
Phone:
+49 (0) 6131 - 921325
website:
www.use-tech.com
Document
number
FlowTimer+ Detect_RF_Set_Manual_EN_V1
Original operating manual
Date of issue
26.06.2020
Print date
26.06.2020
Copyright
usetech GmbH
This documentation including all its parts is protected by copyright.
Any use or modification outside the narrow limits of the copyright
law without the consent of usetech GmbH is inadmissible and liable
to prosecution.
This applies in particular to duplications, translations, microfilming
and storage in electronic systems and processing in these.

Table of contents
05/20 FlowTimer+ Detect RF Set 1
Table of contents
Table of contents.........................................................................1
1General information.............................................................3
1.1 Explanation of symbols .........................................................3
2Technical data......................................................................5
2.1 Radio water detector.............................................................5
2.2 Environmental and climatic conditions (splinter)...................5
2.3 Lifetime..................................................................................5
3Appropriate use....................................................................6
3.1 Improper use .........................................................................7
4System description FlowTimer+ Detect RF Set .................8
4.1 Scope of delivery FlowTimer+ Detect RF Set.......................8
5Installation............................................................................9
5.1 Placement of the radio water detectors.................................9
5.2 Placement of splitter and cables ...........................................9
5.3 Electrical connection .............................................................9
5.4 Commissioning....................................................................10
5.5 Deleting the programming...................................................11
5.6 Functional test.....................................................................11
6Operation and function......................................................12
6.1 Operating states..................................................................12
6.1.1 Normal operation...........................................................................12
6.1.2 Restarting the system....................................................................12
6.1.3 Battery pre-alarm...........................................................................12
7Troubleshooting, maintenance .........................................13
7.1 Maintenance........................................................................13

General information
05/20 FlowTimer+ Detect RF Set 3
1 General information
The operating instructions describe the entire life cycle of the
system. Keep this manual in a way that it is easily accessible to
every user and available again to every new owner of the system.
NOTE
The operating instructions contain important safety
information!
Failure to observe these instructions can lead to dangerous
situations.
The operating instructions must be read and understood.
1.1 Explanation of symbols
DANGER
Warning of an immediate danger!
Failure to observe this warning may result in death or
serious injury.
WARNING
Warns of a possibly dangerous situation!
Failure to observe this warning may result in serious
injury or death.
CAUTION
Warns of a possible danger!
Non-compliance can result in medium or light injuries.
NOTE
Warns of material damage!
Failure to do so may damage the system or equipment.
indicates important additional information, tips and
recommendations that are important for your safety and the
proper functioning of the system.

General information
05/20 FlowTimer+ Detect RF Set 4
refers to information in this operating manual or in other
documentation.
Action steps
The defined sequence of action steps facilitates the correct
and safe use of the system.
Result
Here you will find the result of a sequence of action steps
described.

Technical data
05/20 FlowTimer+ Detect RF Set 5
2 Technical data
2.1 Radio water detector
Operating voltage: 9 V =
Signal volume: approx. 85 dB/3 m
Battery life approx.: 18 months
Transmission frequency: 868 MHz
Permissible ambient temperature: 0 °C ...+40 °C
Dimensions: Ø 101 x H 37 mm
2.2 Environmental and climatic conditions (splinter)
Ambient temperature: +5°C - 40°C
Protection class: IP20
Installation location Splitter, I/O cables and connectors: For
indoor use only
2.3 Lifetime
The function of the FlowTimer+ Detect RF Set must be checked
at the intended intervals (see also chapter 7.1.)

Appropriate use
05/20 FlowTimer+ Detect RF Set 6
3 Appropriate use
Please observe the instructions in this operating manual as well as
the operating conditions and permissible data according to the data
sheet to ensure that the system functions properly and remains
operational for a long time. In case of non-observance of these
instructions as well as in case of unauthorized interventions in the
system, any liability on our part is void, as is the warranty on the
system and accessories!
The FlowTimer+ Detect RF Set consists of two 868 Mhz radio water
detectors of the brand Flammex. One of the detectors is modified
and has an additional cable connection for FlowTimer+.
This wireless water detector with cable connection must be located
at the installation site of FlowTimer+ and monitors e.g. the house
filter. Additional wireless water sensors can be located up to 25
meters away (depending on the environment) (bathroom, kitchen,
etc.), whereby each sensor extends the range!
If a wireless water sensor detects conductive drinking water, the
wireless water sensorwith cable connection immediately blocks the
FlowTimer+ and alarms all of them acoustically.
The FlowTimer+ Detect RF Set contains additional parts to split the
FlowTimer+ I/O connector. This allows the connection of additional
FlowTimer+ accessories if required.
An alarm reset can only be done via the connected FlowTimer+ or
its supply voltage.
Furthermore, the original operating instructions of the manufacturer
FlammEx at www.gev.de must also be observed!
Any other use or use beyond this is considered to be improper use.
usetech GmbH shall not be liable for any damage resulting from
such use. The risk is borne solely by the user.

Appropriate use
05/20 FlowTimer+ Detect RF Set 7
3.1 Improper use
Use other than for the intended purpose in the sense of a
foreseeable misuse:
The supplied I/O Splitter must not be used instead of a
FlowTimer+ Hub to connect FlowTimer+ devices to each other!
It can only be used within an I/O connection between
FlowTimer+ and FlowTimer+ Hub to connect accessories!
The water sensor is only suitable for electrically conductive
drinking water.
The FlowTimer+ Protect is not directly supported, but only
indirectly via a group alarm via FlowTimer+ and FlowTimer+
Hub.
No telephones, ISDN, other devices or adapters may be
connected.

System description FlowTimer+ Detect RF Set
05/20 FlowTimer+ Detect RF Set 8
4 System description FlowTimer+ Detect RF Set
4.1 Scope of delivery FlowTimer+ Detect RF Set
Figure 4.1: Scope of delivery FlowTimer+ Detect RF Set
1
Wireless water detector with 2 m cable and I/O
connector
2
Radio water detector
3
I/O connection cable 0.5 m
4
I/O Splitter
5
2x 9V block battery

Installation
05/20 FlowTimer+ Detect RF Set 9
5 Installation
5.1 Placement of the radio water detectors
Place the water detectors on the floor so that in the event
of an alarm, the three contact surfaces of the detectors
can come into contact with water.
5.2 Placement of splitter and cables
Install the splitter and all I/O cables higher than the water
sensor to protect the splitter and connectors from water
in case of flooding.
5.3 Electrical connection
Insert the I/O connector of the wireless water detector (1) into
the FlowTimer+ I/O connector.
If the connector is already in use, please use the splitter and the
I/O cable.
When the I/O connector is plugged into the socket, this
must cause a clicking noise. If not, please check again
that the connector is properly engaged!
When disconnecting connections, please make sure to
press the locking lugs of the I/O connectors!

Installation
05/20 FlowTimer+ Detect RF Set 10
5.4 Commissioning
Unscrew the upper parts of the two wireless water detectors and
insert a 9V battery in each.
Only 2 wireless water detectors that are currently to be
programmed may be put into operation at the same time
and not all of the detectors used in the house!
Press and hold the internal button for approx. 2-3 seconds on a
wireless water detector. The red LED will then start flashing
approx. once per second.
Release the key again.
The wireless water detector is now in programming mode for
approx. 60 seconds.
Immediately afterwards, press the button for approx. 2-3
seconds on another wireless water detector. The red LED will
then start flashing approx. once per second.
Release the key again.
The wireless water detector is in programming mode for approx.
60 seconds. Both radio water detectors automatically program
each other into a radio group. The programming process can
take up to approx. 60 seconds in total.
If the programming was successful, the red LEDs on both
wireless water detectors light up permanently for 2-3 seconds.
If after approx. 60 seconds the red LEDs do not light up
permanently for 2-3 seconds, the programming procedure was
not successful and the wireless water detectors return to normal
mode.
In this case the programming procedure must be repeated.

Installation
05/20 FlowTimer+ Detect RF Set 11
Up to 30 wireless water detectors can be assigned to one
wireless group!
5.5 Deleting the programming
Press and hold the button of the wireless water detector to be deleted
for approx. 5 seconds until the red LED flashes approx. twice per
second.
After approx. 2-3 seconds, the LED flashes approx. once per second -
keep the button pressed until the LED flashes twice as fast.
Release the key again.
The wireless water detector is then in normal mode again, but without
belonging to a wireless group.
5.6 Functional test
For the test, bridge the three sensor surfaces by placing the wireless
water detector (1) connected to the FlowTimer+ e.g. on a plate that is
slightly filled with water.
The detector emits a loud beep as long as you bypass the sensors.
The FlowTimer+ will immediately shut down.
Reset the Flowtimer+.
For the test, bridge the three sensor surfaces by placing the wireless
water detector (2), for example, on a plate that is slightly filled with
water.
The detector (2) emits a loud signal tone as long as you bypass the
sensors. After that the detector (1) connected to the FlowTimer+ will
give an alarm and the FlowTimer+ will block.
If possible, test with some water on the floor to see if the
alarm works in practice.

Operation and function
05/20 FlowTimer+ Detect RF Set 12
6 Operation and function
6.1 Operating states
6.1.1 Normal operation
An operation is not necessary.
If a wireless water detector detects conductive drinking water,
FlowTimer+ shuts off the system and alarms acoustically.
6.1.2 Restarting the system
An alarm reset can only be done via the connected FlowTimer+ or
its supply voltage.
A further prerequisite for this is that all water detectors are dry again
and the splinter has not become wet!
6.1.3 Battery pre-alarm
The detector emits a short beep if the battery voltage is
too low.
This is quieter than the watermessage and indicates
battery exhaustion.
The battery must be replaced for proper operation.

Troubleshooting, maintenance
05/20 FlowTimer+ Detect RF Set 13
7 Troubleshooting, maintenance
If an alarm has occurred, first check all locations of the
water detectors for possible water accumulation.
If the connected FlowTimer+ shuts off without any reason,
disconnect the I/O connector of the wireless water detector (1) from
the I/O connector of the FlowTimer+.
Now check your FlowTimer+ system according to the
instructions of the respective products.
7.1 Maintenance
Interval
Action
Monthly
Restart the entire system and check its
function (see "Instructions FlowTimer+ Set").
Yearly
The 9V batteries should be replaced
annually or if the sound is no longer clear
and loud when tested.

Packing, transport, storage
05/20 FlowTimer+ Detect RF Set 14
8 Packing, transport, storage
Damage in transit!
Inadequately protected systems can be damaged during
transport.
Transport the system protected from moisture and dirt in
shockproof packaging.
Avoid exceeding or falling below the permissible bearing
temperature.
Protect electrical connections from damage with
protective caps.
The system must be transported or stored in the packaging
provided until installation.
Incorrect storage can cause damage to the system!
Store system dry and dust-free!
Storage temperature: -30°C to +60°C

Disposal and EC declaration of conformity
05/20 FlowTimer+ Detect RF Set 15
9 Disposal and EC declaration of conformity
Information on the Waste Equipment
Ordinance
Act on the placing on the market, return and environmentally
sound disposal of electrical and electronic equipment (Electrical
and Electronic Equipment Act - ElektroG)
Note on the Electrical and Electronic Equipment Act
(ElektroG):
Please dispose of old equipment at a municipal collection
point as prescribed by law, or hand it in at a local retail
outlet free of charge.
Disposal in household waste is expressly prohibited
according to the Ordinance on Waste Equipment!
You can return devices received from us free of charge after
use by sending them back to us by post sufficiently stamped
to the address given in the imprint.
Old appliances containing harmful substances are marked
with the symbol of a crossed-out dustbin.
Battery Note
Used batteries must not be disposed of with unsorted
household waste. Owners of used batteries are legally
obliged to return them and can return them free of charge to
the points of sale. Batteries contain substances harmful to
the environment and health and must therefore be disposed
of properly.