manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Satel
  6. •
  7. Security Sensor
  8. •
  9. Satel COBALT User manual

Satel COBALT User manual

Other manuals for COBALT

3

This manual suits for next models

2

Other Satel Security Sensor manuals

Satel MAGENTA User manual

Satel

Satel MAGENTA User manual

Satel AQUA PET User manual

Satel

Satel AQUA PET User manual

Satel AOCD-250 User manual

Satel

Satel AOCD-250 User manual

Satel AGATE User manual

Satel

Satel AGATE User manual

Satel COBALT Pro User manual

Satel

Satel COBALT Pro User manual

Satel OPAL Pro User manual

Satel

Satel OPAL Pro User manual

Satel ACTIVA-2 User manual

Satel

Satel ACTIVA-2 User manual

Satel AQUA Series User manual

Satel

Satel AQUA Series User manual

Satel MGD-300 User manual

Satel

Satel MGD-300 User manual

Satel APMD-250 User manual

Satel

Satel APMD-250 User manual

Satel ARD-100 User manual

Satel

Satel ARD-100 User manual

Satel ABAX 2 APD-200 User manual

Satel

Satel ABAX 2 APD-200 User manual

Satel AQUA RING User manual

Satel

Satel AQUA RING User manual

Satel SX6-TO User manual

Satel

Satel SX6-TO User manual

Satel APMD-150 User manual

Satel

Satel APMD-150 User manual

Satel AVD-100 User manual

Satel

Satel AVD-100 User manual

Satel AGD-200 User manual

Satel

Satel AGD-200 User manual

Satel MAGENTA User manual

Satel

Satel MAGENTA User manual

Satel micra MXD-300 User manual

Satel

Satel micra MXD-300 User manual

Satel OPAL User manual

Satel

Satel OPAL User manual

Satel AQUA S User manual

Satel

Satel AQUA S User manual

Satel AXD-200-DG User manual

Satel

Satel AXD-200-DG User manual

Satel ASD-110 User manual

Satel

Satel ASD-110 User manual

Satel XD-2L User manual

Satel

Satel XD-2L User manual

Popular Security Sensor manuals by other brands

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

Rielta Ladoga MK-RK installation guide

Rielta

Rielta Ladoga MK-RK installation guide

Mirion Technologies ACCURAD PRD user manual

Mirion Technologies

Mirion Technologies ACCURAD PRD user manual

Bosch DS835 installation instructions

Bosch

Bosch DS835 installation instructions

Lamptime ST05C instructions

Lamptime

Lamptime ST05C instructions

Ubiquiti MFI-MSC quick start guide

Ubiquiti

Ubiquiti MFI-MSC quick start guide

Subsite 910R Support

Subsite

Subsite 910R Support

Aleph XC-1XTEU manual

Aleph

Aleph XC-1XTEU manual

Pima LARIS QUAD installation instructions

Pima

Pima LARIS QUAD installation instructions

Solinst 301 user guide

Solinst

Solinst 301 user guide

Pyronix KX10DTP quick start guide

Pyronix

Pyronix KX10DTP quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

®
DIGITAL DUAL DETECTORS
COBALT, COBALT Plus,
&COBALT Pro
cobalt_ewa_e 03/05
A microwave (MW) sensor and
a dual pyroelectric element are
used in the COBALT detector
construction.
An additional feature in the
COBALT Plus is the antimasking
function, realized by microwave
sensor (does not refer to infrared
sensor). The COBALT Pro employs
an MW sensor and a quad pyro
element. The detector is also
provided with the antimasking
function.
CONTACTS:
COM - common ground (0V)
12V - supply input (9-16V DC)
NC - alarm relay (NC)
WRN - antimasking relay (NC) -
only the COBALT Plus and
COBALT Pro detectors
TMP - tamper contact (NC)
Four pairs of pins are used for setting
the dual detector working parameters
(see Table).
The COBALT, COBALT Plus
& COBALT Pro dual detectors can
operate in two modes: the basic mode
or the microwave counting mode
(MW).
In the basic mode the detector will only
generate an alarm when motion is
detected by both sensors. The first
system (infrared or MW) which detects
a motion will activate a 10-second time
interval, during which the other sensor
must also detect motion for the detector
to generate an alarm signal. If the other
sensor fails to confirm the alarm condition within 10 seconds of the motion being detected by
the first sensor, the sensor will generate no alarm.
JP1 JP2 JP3 JP4
Low sensitivity, PIR system
Medium sensitivity, PIR system
High sensitivity, PIR system
Basic mode
MW counting mode
LED indicator ON
LED indicator OFF
- pins open - pins shorted
Fig. 1. View of COBALT Plus /
COBALT Pro detector board
JP1
JP2
JP3
JP4
PIR SENS
COM 12V NC NC
MODE
LED ON / OFF
-µW SENS. +
alarm rela
y
antimasking relay
pyro element
LED
microwave head
operating parameters
settin
g
p
ins
potentiometer control of
microwave channel
detection sensitivity (range)
position indicator
WRN WRN TMP TMP
tamper contact
2
When in the microwave counting mode (MW), the detector will generate an alarm both in the
above mentioned case, upon detection of a motion by both systems, as well as after 16
excitations of the microwave sensor in the time not longer than 30 minutes, with no violation
of the PIR sensor.
NOTE: Remember to set an appropriate sensitivity of microwave channel detection,
since the microwaves are capable of penetrating, for example, through gypsum
walls, doors, etc., which may cause generation of false alarms.
The LED allows the installer to check the detector for correct functioning and to
approximately determine the protected area:
-the LED lights red– alarm,
-the LED lights green – excitation of PIR or MW system.
For 30 seconds after the power is turned on, the detector remains in a starting state, which is
signalized by a rapid blinking of the LED, alternately, green and red. Only then the detector
enters its operational readiness state.
The detector monitors the supply voltage. If the voltage drops below 9V (±5%) for more than
2 seconds, the detector will signalize a violation state until a voltage of minimum 9V (±5%) is
restored.
1. Installation
The detector is designed for indoor installation. It can be mounted on the wall, either directly
or on the included holder.
Prior to installation of the detector housing, remove the electronics board and brake out
adequate openings for screws and cable in the rear panel of the housing.
It is advisable that you exercise particular care to prevent the pyro element from
getting dirty or damaged during installation.
Figure 2 shows typical examples of connecting the detectors in EOL and 2EOL configuration.
Resistors should be mounted inside the detector housing.
Figure 2. Example of connecting dual detectors
TMP TMP COM 12V NC NC
COBALT dual detector
2R
WRN WRN TMP TMP COM 12V NC NC
COBALT Plus /
COBALT Pro
dual detector
RR
Z2 & Z7 - programmed as „24h TAMPER” – NC type
+12V Z1 COM Z2 Z3 COM Z4 COM Z5 Z6 COM Z7 Z8 COM Z9 Z10 COM Z11 Z12
3
2. Antimasking
The antimasking function in COBALT detectors is based on detection of objects, which reflect
microwaves and move close in front of the detector (up to 10 – 20 centimeters), thus
preventing any attempts to cover it. For the protection against consequences of covering
detector with the material which does not reflect the microwaves, but isolate from IR
radiation, it is necessary to choose the detector microwave counting mode (take off the JP3
jumper).
3. Lenses
In the detector is mounted an extra wide angle lens, however, it is possible to replace it by
buying another lens with different characteristics (range, number of beams, angle of view).
Lenses are available with the following characteristics:
№Lens type Range Angle of view
1 extra wide angle (EWA) 15m 141.2°
2 long range with access zone
monitoring (LR) 30m main beam - 3m wide (at the end of range)
3 vertical barrier 22.5m 2.2m wide (at the end of range)
NOTE: The detector operating range should be selected to match the size of space where
the detector will be installed. The size of the space along the main direction of
detector positioning is not to be less than 1/3 the nominal range of the detector.
Improper selection of the lens may cause excessive sensitivity and trigger false
alarms.
4. Technical data
Supply voltage ............................................................................................. 9V...16V DC
Nominal supply voltage ..................................................................................... 12V DC
Mean power consumption (±10%)..........................................................................24mA
Violation signaling time................................................................................................ 2s
Range of pyroelectric sensor with standard lens...................................................... 15m
Range of microwave sensor ......................................................................from 3 to 20m
Operating temperature range ........................................................................-10...+50°C
Detectable motion speed............................................................................... up to 3 m/s
Dimensions of housing ............................................................................ 63x136x49mm
Recommended installation height ........................................................................... 2.1m
Latest EC declaration of conformity and product approval certificates can
be downloaded from our Web site www.satel.pl
4
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
[email protected]
www.satel.pl