DIGITAL DUAL DETECTORS
COBALT, COBALT Plus,
&COBALT Pro
cobalt_ewa_e 03/05
A microwave (MW) sensor and
a dual pyroelectric element are
used in the COBALT detector
construction.
An additional feature in the
COBALT Plus is the antimasking
function, realized by microwave
sensor (does not refer to infrared
sensor). The COBALT Pro employs
an MW sensor and a quad pyro
element. The detector is also
provided with the antimasking
function.
CONTACTS:
COM - common ground (0V)
12V - supply input (9-16V DC)
NC - alarm relay (NC)
WRN - antimasking relay (NC) -
only the COBALT Plus and
COBALT Pro detectors
TMP - tamper contact (NC)
Four pairs of pins are used for setting
the dual detector working parameters
(see Table).
The COBALT, COBALT Plus
& COBALT Pro dual detectors can
operate in two modes: the basic mode
or the microwave counting mode
(MW).
In the basic mode the detector will only
generate an alarm when motion is
detected by both sensors. The first
system (infrared or MW) which detects
a motion will activate a 10-second time
interval, during which the other sensor
must also detect motion for the detector
to generate an alarm signal. If the other
sensor fails to confirm the alarm condition within 10 seconds of the motion being detected by
the first sensor, the sensor will generate no alarm.
JP1 JP2 JP3 JP4
Low sensitivity, PIR system
Medium sensitivity, PIR system
High sensitivity, PIR system
Basic mode
MW counting mode
LED indicator ON
LED indicator OFF
- pins open - pins shorted
Fig. 1. View of COBALT Plus /
COBALT Pro detector board
JP1
JP2
JP3
JP4
PIR SENS
COM 12V NC NC
MODE
LED ON / OFF
-µW SENS. +
alarm rela
y
antimasking relay
pyro element
LED
microwave head
operating parameters
settin
g
p
ins
potentiometer control of
microwave channel
detection sensitivity (range)
position indicator
WRN WRN TMP TMP
tamper contact
2
When in the microwave counting mode (MW), the detector will generate an alarm both in the
above mentioned case, upon detection of a motion by both systems, as well as after 16
excitations of the microwave sensor in the time not longer than 30 minutes, with no violation
of the PIR sensor.
NOTE: Remember to set an appropriate sensitivity of microwave channel detection,
since the microwaves are capable of penetrating, for example, through gypsum
walls, doors, etc., which may cause generation of false alarms.
The LED allows the installer to check the detector for correct functioning and to
approximately determine the protected area:
-the LED lights red– alarm,
-the LED lights green – excitation of PIR or MW system.
For 30 seconds after the power is turned on, the detector remains in a starting state, which is
signalized by a rapid blinking of the LED, alternately, green and red. Only then the detector
enters its operational readiness state.
The detector monitors the supply voltage. If the voltage drops below 9V (±5%) for more than
2 seconds, the detector will signalize a violation state until a voltage of minimum 9V (±5%) is
restored.
1. Installation
The detector is designed for indoor installation. It can be mounted on the wall, either directly
or on the included holder.
Prior to installation of the detector housing, remove the electronics board and brake out
adequate openings for screws and cable in the rear panel of the housing.
It is advisable that you exercise particular care to prevent the pyro element from
getting dirty or damaged during installation.
Figure 2 shows typical examples of connecting the detectors in EOL and 2EOL configuration.
Resistors should be mounted inside the detector housing.
Figure 2. Example of connecting dual detectors
TMP TMP COM 12V NC NC
COBALT dual detector
2R
WRN WRN TMP TMP COM 12V NC NC
COBALT Plus /
COBALT Pro
dual detector
RR
Z2 & Z7 - programmed as „24h TAMPER” – NC type
+12V Z1 COM Z2 Z3 COM Z4 COM Z5 Z6 COM Z7 Z8 COM Z9 Z10 COM Z11 Z12
3
2. Antimasking
The antimasking function in COBALT detectors is based on detection of objects, which reflect
microwaves and move close in front of the detector (up to 10 – 20 centimeters), thus
preventing any attempts to cover it. For the protection against consequences of covering
detector with the material which does not reflect the microwaves, but isolate from IR
radiation, it is necessary to choose the detector microwave counting mode (take off the JP3
jumper).
3. Lenses
In the detector is mounted an extra wide angle lens, however, it is possible to replace it by
buying another lens with different characteristics (range, number of beams, angle of view).
Lenses are available with the following characteristics:
№Lens type Range Angle of view
1 extra wide angle (EWA) 15m 141.2°
2 long range with access zone
monitoring (LR) 30m main beam - 3m wide (at the end of range)
3 vertical barrier 22.5m 2.2m wide (at the end of range)
NOTE: The detector operating range should be selected to match the size of space where
the detector will be installed. The size of the space along the main direction of
detector positioning is not to be less than 1/3 the nominal range of the detector.
Improper selection of the lens may cause excessive sensitivity and trigger false
alarms.
4. Technical data
Supply voltage ............................................................................................. 9V...16V DC
Nominal supply voltage ..................................................................................... 12V DC
Mean power consumption (±10%)..........................................................................24mA
Violation signaling time................................................................................................ 2s
Range of pyroelectric sensor with standard lens...................................................... 15m
Range of microwave sensor ......................................................................from 3 to 20m
Operating temperature range ........................................................................-10...+50°C
Detectable motion speed............................................................................... up to 3 m/s
Dimensions of housing ............................................................................ 63x136x49mm
Recommended installation height ........................................................................... 2.1m
Latest EC declaration of conformity and product approval certificates can
be downloaded from our Web site www.satel.pl
4
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
[email protected]
www.satel.pl

Other manuals for COBALT

3

This manual suits for next models

2

Other Satel Security Sensor manuals

Satel AGD-100-BR User manual

Satel

Satel AGD-100-BR User manual

Satel micra MPD-300 User manual

Satel

Satel micra MPD-300 User manual

Satel CD-2 User manual

Satel

Satel CD-2 User manual

Satel micra MXD-300 User manual

Satel

Satel micra MXD-300 User manual

Satel ABAX 2 APD-200 User manual

Satel

Satel ABAX 2 APD-200 User manual

Satel INDIGO User manual

Satel

Satel INDIGO User manual

Satel APD-100 User manual

Satel

Satel APD-100 User manual

Satel OPAL Pro User manual

Satel

Satel OPAL Pro User manual

Satel COBALT User manual

Satel

Satel COBALT User manual

Satel AQUA RING S User manual

Satel

Satel AQUA RING S User manual

Satel AQUA PET User manual

Satel

Satel AQUA PET User manual

Satel AVD-100 User manual

Satel

Satel AVD-100 User manual

Satel A D-200 Series User manual

Satel

Satel A D-200 Series User manual

Satel abax2 User manual

Satel

Satel abax2 User manual

Satel SX6-TO User manual

Satel

Satel SX6-TO User manual

Satel FD-1 User manual

Satel

Satel FD-1 User manual

Satel MAGENTA User manual

Satel

Satel MAGENTA User manual

Satel XD-2 User manual

Satel

Satel XD-2 User manual

Satel MGD-300 User manual

Satel

Satel MGD-300 User manual

Satel abax 2 ACD-220 User manual

Satel

Satel abax 2 ACD-220 User manual

Satel MAGENTA User manual

Satel

Satel MAGENTA User manual

Satel APMD-150 User manual

Satel

Satel APMD-150 User manual

Satel abax 2 ADD-200 User manual

Satel

Satel abax 2 ADD-200 User manual

Satel ASD-110 User manual

Satel

Satel ASD-110 User manual

Popular Security Sensor manuals by other brands

Winland Electronics WaterBug WB350 quick start guide

Winland Electronics

Winland Electronics WaterBug WB350 quick start guide

Stahl YL4IS Series operating instructions

Stahl

Stahl YL4IS Series operating instructions

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

PASCO

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

TTK FG-NET-LL quick start guide

TTK

TTK FG-NET-LL quick start guide

Niko 350-20085 manual

Niko

Niko 350-20085 manual

hager WYW51 Q Series quick start guide

hager

hager WYW51 Q Series quick start guide

Alcatel Vacuum Technology ASM 182 TD+ user manual

Alcatel Vacuum Technology

Alcatel Vacuum Technology ASM 182 TD+ user manual

SICK Prime KTX-WB94141252ZZZZ manual

SICK

SICK Prime KTX-WB94141252ZZZZ manual

Honeywell Ex-Or MLS Installation and commissioning instructions

Honeywell

Honeywell Ex-Or MLS Installation and commissioning instructions

Robus R100LEDCCT3E-01 instruction manual

Robus

Robus R100LEDCCT3E-01 instruction manual

C-LOGIC 760-SD instruction manual

C-LOGIC

C-LOGIC 760-SD instruction manual

SICK WEU 26/2 Technical description

SICK

SICK WEU 26/2 Technical description

Cisco MERAKI MT12 installation guide

Cisco MERAKI

Cisco MERAKI MT12 installation guide

Mitsubishi Electric LX-005TD instruction manual

Mitsubishi Electric

Mitsubishi Electric LX-005TD instruction manual

Halma BEA IXIO-DO1 I quick start guide

Halma

Halma BEA IXIO-DO1 I quick start guide

Interlogix ACL800SUW-BSPX installation manual

Interlogix

Interlogix ACL800SUW-BSPX installation manual

Abilia Gewa Andromeda IR-DET user manual

Abilia

Abilia Gewa Andromeda IR-DET user manual

iET PRS-200 Series Operation manual

iET

iET PRS-200 Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.